Dockerfile: self-contained image with corpus + Chroma + BM25 baked in. Drawbar's compose pulls + runs without volume mounts. Built from sources.json (labels schema), PRODUCT_NAME=crop_chem by default, HYBRID_SEARCH=true (always-on for production quality). RERANK_URL + OLLAMA_URL get set at compose time. .gitea/workflows/refresh.yml: monthly cron (1st @ 06:00 UTC) does full scrape → reindex → image push. Scrapes Bayer (~30 min) + EPA PPLS row-crop filtered (~7h). Skips reindex+push if no corpus diff. Tags pushed: :latest, :<sha12>, :corpus-<YYYY.MM.DD>. .gitea/workflows/image-only.yml: on-demand or auto on code-only pushes to main (paths: docs_mcp/, rag/, scrape/, requirements.txt, Dockerfile, sources.json). Reindexes from committed corpus, builds image, pushes. ~10 min vs ~9h full refresh. .gitignore: corpus/ now COMMITTED (4,159 labels, 265 MB of .md + sidecars). Lets image-only.yml rebuild indexes without re-scraping. chroma/ + bm25/ still gitignored (regenerable binary indexes). .dockerignore: drops venv, eval results, PLAN/README/CLAUDE.md, deploy/, .git/ — keeps the image lean. corpus + chroma + bm25 explicitly NOT in dockerignore (those go INTO the image). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,48 @@
|
||||
# ATRAZINE PLUS LINURON
|
||||
|
||||
- EPA Reg No: **19713-79**
|
||||
- Registrant: DREXEL CHEMICAL COMPANY
|
||||
- Signal word: Caution
|
||||
- Active ingredients: Linuron (30.8%); Atrazine (30.8%)
|
||||
- Label accepted: 1997-04-21
|
||||
- Source PDF: https://www3.epa.gov/pesticides/chem_search/ppls/019713-00079-19970421.pdf
|
||||
|
||||
---
|
||||
Drexel Chemical Company
|
||||
;97/3- '71
|
||||
.-
|
||||
SUPPLEMENTAL LABELING
|
||||
Drexel Atrazine Plus Linuron
|
||||
EPA Reg. No. 19713-79
|
||||
All applicable directions, restrictions and precautions on the EPA
|
||||
registered label are to be followed. This label must be ·in the possession of
|
||||
the actual pr()duct user at the time of application.
|
||||
TILE-TERRACED FIELDS CONTAINING STANDPIPES
|
||||
To ensure protection of surface water from runoff through standpipes and tile
|
||||
outlets in terraced fields, one of the following options may be used:
|
||||
1) Do not apply this product within 66 feet of standpipes in tile-outieUed terraced
|
||||
fields.
|
||||
2) Apply this product to the entire tile-outletted terraced field and immediately
|
||||
incorporate it to a depth of 2 to 3 inches in the entire tile-outletted terraced field.
|
||||
3) Apply this product to the entire tile-outletted terraced field under a no-till
|
||||
practice only when high crop residue management practices are used. High crop
|
||||
residue management practice is described as a crop management practice
|
||||
where little or no crop residue is removed from the field during or after crop
|
||||
harvest.
|
||||
-- - - -
|
||||
EPA Reg. No. 19713-79
|
||||
EPA Est. No. 19713-MS-1
|
||||
labeling Date: March 14, 1997
|
||||
Manufactured by:
|
||||
Drexel Chemical Company
|
||||
. P. O. Box 13327
|
||||
Memphis, TN 38113-0327
|
||||
1700 Channel Avenue· Post Office Box 13327· Memphis, Tennessee 38113"()327
|
||||
Phone: (901) 774-4370 • Fax: (901) 774-4555 • Cable Address: Drexel Chern Mis.
|
||||