justin 6548cf7fbe Section 1 GUI: Vehicle Info, Emissions Readiness, Freeze Frame, Trip/Performance
- Diagnostics menu: Vehicle Info (VIN/cal/ECU), Emissions Readiness (I/M
  monitors + MIL -> pass/fail), Freeze Frame (snapshot + capturing DTC).
  All routed through the scheduler one-off path; dialogs, no docked panels.
- New Trip / Performance view (View menu, center page): live + average MPG,
  trip distance/fuel/time, and 0-60 / 1/4-mile timers. The controller keeps
  SPEED + MAF polled in the background and feeds TripComputer/PerformanceMeter
  every tick, so trips accumulate regardless of the active view. Honest MAF
  caveat shown for speed-density/diesel vehicles.

Validated headless against MockLink: VIN dialog, readiness dialog, freeze-frame
dialog, and the live trip page (28.8 mpg / distance accruing). All tests pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 19:43:31 -04:00
justin d893ff383a Gauge redline zones + C/F units toggle + cleaner dials
Gauges:
- Optional per-metric warning zones (warn_hi/redline_hi/warn_lo/redline_lo) in
  the profile schema; gauges draw colored redline/warn bands and color the
  needle + readout by zone. Default neutral when unset (no false redline).
- Removed the value progress-arc fill (it dominated the dial / looked wrong) ->
  clean tach face: bezel, ticks, numeric scale, needle, redline band, readout.
- Auto-derivation rejected: bad direction/threshold vary per metric, so zones
  are config (with a sensible neutral default).

Units:
- New Units menu: Temperature C / F. Converts gauges, graph, table, and PID
  browser (values, scale, zones, unit labels) at display time; data stays C.

Ford 6.0 profile: zones for ICP (red<500), FICM (red<40/amber40-48/green48+),
ECT/EOT (high redline), RPM (redline 3800), boost, battery; tightened FICM
(38-52) and battery (9-15) ranges so redline bands land sensibly.

Docs: profiles/PROFILE_SPEC.md -- canonical, AI-agent-ready profile spec
(schema, formula language, zones, confidence, rules); README points to it.

Validated headless: zones parse/classify, F conversion (112C->233.6F, zones
converted), gauges render; obdcore + diagnostics tests pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 15:52:49 -04:00
justin 03223dfd6c Rename project to OBDash + per-metric colored multi-axis
Rename: the app is vehicle-agnostic, so 'ford-obd' was wrong. Rebranded all
code/docs/profile authors to OBDash; Gitea repo renamed justin/ford-obd ->
justin/obdash (remote + description updated). Ford the make and the
ford-6.0-powerstroke profile are unchanged (that vehicle really is a Ford).

Multi-axis upgrade (per request):
- MultiAxisPlot now gives each METRIC its own Y axis, each axis colored to
  match its line; the primary metric owns the LEFT axis, others stack right.
- Click a line to promote it to the left axis (sigClicked -> set_primary).
- Cleaner teardown (no removeItem warnings); axis label no longer doubles the
  unit; Normalize round-trips.

Validated headless: colored per-metric axes, promote-to-left, gauge view,
normalize toggle, profile switch; obdcore + diagnostics tests pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 15:25:26 -04:00
justin e7e04b740e Diagnostics as dialogs (no dock) + real car-style gauges
Diagnostics: removed the always-on right-side Diagnostics dock (it ate screen
space on every view). Read Codes now opens a modal dialog listing codes
grouped stored/pending/permanent with descriptions (no-start codes bold red);
Clear Codes keeps its confirmation, and on re-read pops a dialog only if codes
returned. Dropped the View > Show Diagnostics Panel toggle.

Gauges: replaced the plain progress-arc with a proper automotive dial -- round
face + bezel, major/minor tick marks, a numeric scale (rounded labels), a red
needle + center hub, a colored rim arc for the value, and an amber peak tick.
Digital readout + name/unit below.

Validated headless: no Diagnostics dock; Read Codes opens the Trouble Codes
dialog; gauge view renders. obdcore + diagnostics tests still pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 15:12:49 -04:00
justin f2308cd4eb P2: true multi-axis overlay + gauge view
gui/widgets.py:
- MultiAxisPlot -- overlay with one Y axis PER UNIT (psi/V/rpm/C/%), linked
  ViewBoxes on X, so mixed-scale signals are readable at true values
  (base left axis + up to 4 right axes).
- SinglePlot -- one shared axis for the Normalize (% of range) mode.
- ArcGauge -- 270deg arc gauge with peak tick + numeric readout, own dark bg.
- GaugeGrid -- scrollable grid of gauges.

gui/main.py:
- Graph page is now a multi-axis/single-axis sub-stack; Normalize toggles
  between true multi-axis (raw) and single-axis (%). curves map key->color;
  plot ops route to the active graph widget.
- Gauge View menu enabled (3rd center page); gauges update on tick with peak.
- Theme applies to both plot widgets; profile switch clears graphs/gauges.

Fix: ArcGauge QPen built via setCapStyle (the QPen(...cap=...) kwarg segfaults
PySide6). Validated headless: driving preset -> 6 unit groups across 5 axes,
gauge view renders, normalize round-trips, profile-switch clears cleanly.
obdcore + diagnostics tests still pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 15:07:57 -04:00
justin f3f0bf2a77 Make app vehicle-agnostic: JSON vehicle profiles + menu bar
Vehicle data is now DATA, not code. PIDs/scaling/DTCs/presets live in
profiles/*.json; the app loads them at runtime, so it works across vehicles
and others can contribute profiles (open source).

Core:
- obdcore/formula.py: safe AST evaluator for scaling formulas (A/B/... byte
  vars, Torque/FORScan convention). Only arithmetic/bitwise + min/max/abs/
  round/int/float; names/attrs/arbitrary calls rejected at load -> a community
  profile CANNOT execute code.
- obdcore/profile.py: load/save/list profiles; compiles each formula into a
  decode callable. registry.py now profile-backed (PidRegistry/DtcDatabase
  take a Profile); hardcoded Ford table removed.
- store.py: clear()/snapshot()/export_csv() for capture management.

Profiles:
- profiles/ford-6.0-powerstroke.json (27 PIDs, verified formulas, DTCs)
- profiles/generic-obd2.json (standard SAE Mode-01 base, any vehicle)
- profiles/README.md (schema + formula language + contributing)

GUI:
- Menu bar: File (new/record/export/replay capture, quit), Profile (switch/
  load/import/reload/edit-JSON/export, live profile list), View (Graph/Table
  views, gauges P2, toggle PID dock, normalize, light/dark theme), Help
  (about/confidence legend/profile info).
- PID browser + presets rebuild on profile switch; added Table view; raw-JSON
  profile editor dialog (validates schema+formulas before saving).

Tests: profiles load+compile, formula sandbox rejects hostile input, decoders
still match real truck bytes, crank/derived/dead-PID/replay -- all pass.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 14:34:33 -04:00
justin 4589904b97 P1: PySide6 + pyqtgraph GUI shell (PID browser + live overlay plot)
First graphical frontend on obdcore. Cross-platform (Win/mac/Linux).

- gui/controller.py: owns link/registry/store/scheduler; subscribe == poll ==
  plot; per-PID rates (ICP/FICM/RPM fast); optional CSV recording.
- gui/main.py: connection bar (port dropdown via find_ports, baud, Mock,
  connect), left PID browser grouped by system with live values + confidence
  badges + checkboxes, central pyqtgraph overlay plot with legend, Normalize
  (% of range) toggle for mixed-scale PIDs, Crank/Driving/Vitals presets,
  10Hz refresh reading the store off the acquisition thread.
- run_gui.py launcher; requirements-gui.txt.
- store.py: lock Channel push/series (GUI reads while scheduler writes).
- docs/gui-p1-preview.png: validated render (mock crank, ICP ramp to 540).

Validated headless (offscreen Qt): connect(mock) -> crank preset -> ICP
streams past 500 -> normalize -> uncheck removes curve -> clean disconnect.
obdcore tests still pass after the locking change.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs