justin 23c92018c1 Fix #8: scheduler survives link death; timed-out one-offs cancelled
- A transport exception in the poll loop killed the thread silently, leaving the
  GUI on a frozen 'Connected' dashboard and blocking run_oneoff callers for the
  full timeout. _loop now catches it -> stops, fails pending one-offs with the
  real error, and calls an on_error callback. Controller wires on_error to flag
  the connection dead; the GUI detects it in _tick and tears down with a
  'Connection lost' dialog.
- A run_oneoff that timed out left its job queued, so it executed LATER on the
  shared link -- a ghost/duplicate vehicle command. Jobs now carry
  cancelled/started flags under a lock; on timeout a not-yet-started job is
  cancelled (skipped by _drain_oneoffs), and a started one reports 'still
  running -- do NOT retry'. stop() also frees stranded submitters.
- tests/test_scheduler.py: cancel-on-timeout, freed-on-death, loop-survives.

Closes #8

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-07-01 19:33:33 -04:00
justin 0fea0908c8 Add Tools/Diagnostics: thread-safe DTC read/clear + Diagnostics panel
The polling thread owns the ELM327, so reading/clearing trouble codes from
the GUI thread would race PID reads and corrupt the stream. Add a one-off
command path that serializes ad-hoc link work onto the polling thread.

obdcore/scheduler.py:
- PollScheduler.run_oneoff(fn, timeout) enqueues a callable (queue.Queue +
  threading.Event) and blocks for its result, re-raising the callable's
  exception. tick() drains queued one-offs at its very top, so they run on
  the same thread that does PID reads -- never concurrently. When the
  scheduler thread isn't running, the job is drained inline on the caller
  (still serialized vs tick(), safe because nothing else touches the link).

gui/controller.py:
- Controller.read_dtcs() -> {"stored","pending","permanent"} (modes 03/07/0A,
  svc 0x43/0x47/0x4A) and clear_dtcs() -> bool. Both route through the
  scheduler one-off when a scheduler exists, else call the link directly.

gui/main.py:
- Diagnostics menu (Read Codes / Clear Codes...) and a right-side QDockWidget
  listing codes grouped Stored/Pending/Permanent. Each row is code +
  description + system from DtcDatabase; no_start codes are flagged bold red.
- Clear is guarded by a confirmation warning (erases codes + freeze frame;
  honest "the code comes right back" / permanent-codes-won't-clear tone from
  run_clear in obd_reader.py). On confirm: clear, then re-read immediately and
  show whatever returned, reporting active faults that came straight back.

tests/test_diagnostics.py:
- one-off returns its value, re-raises exceptions, is drained before a tick's
  PID reads, and runs on a live background thread while polling continues.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 14:53:57 -04:00
justin 6bee9c0d7f Scaffold obdcore (headless acquisition core) + ARCHITECTURE.md
Foundation for the PySide6 + pyqtgraph Windows GUI, shared with the terminal
tool. Pure data/IO -- no Qt, no curses.

obdcore/
  link.py      ElmLink   -- ELM327 serial (Mode-01/22, ATRV, DTC read/clear)
  mock.py      MockLink  -- synthetic crank for tests + GUI dev (no truck)
  registry.py  PidRegistry (verified Ford 6.0 PIDs + confidence) + DtcDatabase
  scheduler.py PollScheduler -- prioritized round-robin polling, dead-PID park,
               derived channels; tick() is fake-clock test-drivable
  store.py     TimeSeriesStore (ring buffers + min/max) + CsvRecorder/replay

Design centers on the ELM327 bandwidth limit (~7-15 reads/sec): the active
view subscribes PIDs at chosen rates; acquisition runs off the UI thread;
the GUI only reads the store. FICM_M (09D0) promoted to verified after the
2026-06-30 on-truck crank read (48.0V, intermittent).

tests/test_obdcore.py: decoders vs real truck bytes, crank ramp + peak,
derived BOOST, dead-PID park/revive, record/replay roundtrip -- all pass.

ARCHITECTURE.md: layers, data model, GUI plan, 6.0 stock-PID limits
(no EGT/oil-PSI), feature backlog, P0-P5 roadmap.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>