justin a9b2e133c0 Add dedicated --crank monitor for no-start diagnosis
Big ICP readout focused on the cranking scenario:
- Wide ICP bar with the 500-psi firing threshold marked (|)
- Rolling ASCII trace chart of the ICP build-up (10 rows; renders anywhere,
  no unicode) -- clearly shows ICP climbing above/below the 500 firing line
- Peak-hold (the crank's max ICP, the money number) + pass/fail verdict
- FICM main / battery / RPM secondaries with sag (min) tracking
- --dash-log writes a CSV (t,icp,ficm,batt,rpm) while you watch
- On exit prints peak ICP + verdict (reached 500 / suspect oil bleed-off)

Validated end-to-end via a mock crank: ICP ramp past 500, peak capture,
battery-sag capture, trace resolution, CSV logging, clean terminal restore.

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-30 09:15:14 -04:00
justin c94caefd50 Add real-time live gauge dashboard (--dash)
In-place updating CLI dashboard for watching data while cranking/running.
Pure-ANSI (no new deps; works on Windows 10+ terminals).

- Color-coded gauges (green/yellow/red) by no-start thresholds
- Live min/max per gauge -> captures PEAK ICP during a crank
- ASCII bars for ICP and FICM main voltage
- Presets: crank (ICP/FICM/batt/RPM, fastest), vitals (default), full
- Dead-PID auto-skip keeps refresh rate up when 09xx FICM PIDs no-respond
- --dash-log PATH writes a CSV while you watch (streaming log preserved)
- q=quit, r=reset min/max; cross-platform non-blocking key input

Validated: render + decoders vs the truck's real scan bytes, and the full
dashboard() loop via a mock ELM (ICP climb across the 500psi firing
threshold, peak capture, battery-sag capture, CSV logging, clean exit).

Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_016yT89n4zR4qbrySoSiEyZs
2026-06-29 23:27:29 -04:00
justin 0491d37a2e ford-obd: ELM327 OBD-II reader + 6.0 Power Stroke no-start triage
Read stored/pending/permanent DTCs, decode with 6.0-relevant codes flagged,
guarded mode-04 clear (--clear), key live PIDs + battery voltage, and a
6.0 no-start triage checklist. Tested against a CH340 ELM327 v1.5 adapter.