Files
justin a97107de46
Image rebuild (skip scrape) / build (push) Failing after 1h37m12s
docker: production image + Gitea Actions for monthly refresh
Dockerfile: self-contained image with corpus + Chroma + BM25 baked
in. Drawbar's compose pulls + runs without volume mounts. Built from
sources.json (labels schema), PRODUCT_NAME=crop_chem by default,
HYBRID_SEARCH=true (always-on for production quality). RERANK_URL +
OLLAMA_URL get set at compose time.

.gitea/workflows/refresh.yml: monthly cron (1st @ 06:00 UTC) does
full scrape → reindex → image push. Scrapes Bayer (~30 min) +
EPA PPLS row-crop filtered (~7h). Skips reindex+push if no corpus
diff. Tags pushed: :latest, :<sha12>, :corpus-<YYYY.MM.DD>.

.gitea/workflows/image-only.yml: on-demand or auto on code-only
pushes to main (paths: docs_mcp/, rag/, scrape/, requirements.txt,
Dockerfile, sources.json). Reindexes from committed corpus, builds
image, pushes. ~10 min vs ~9h full refresh.

.gitignore: corpus/ now COMMITTED (4,159 labels, 265 MB of .md +
sidecars). Lets image-only.yml rebuild indexes without re-scraping.
chroma/ + bm25/ still gitignored (regenerable binary indexes).

.dockerignore: drops venv, eval results, PLAN/README/CLAUDE.md,
deploy/, .git/ — keeps the image lean. corpus + chroma + bm25
explicitly NOT in dockerignore (those go INTO the image).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-24 12:32:41 -04:00

1064 lines
57 KiB
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
# PREVICUR
- EPA Reg No: **264-678**
- Registrant: BAYER CROPSCIENCE, LLC
- Signal word: Caution
- Active ingredients: Propamocarb hydrochloride (66.5%)
- Label accepted: 2024-08-16
- Source PDF: https://www3.epa.gov/pesticides/chem_search/ppls/000264-00678-20240816.pdf
---
August 16, 2024
Anne Pfleiger
Registration Manager
Bayer CropScience LP
800 N. Lindbergh Blvd
St. Louis, MO 63137
Subject: Label Amendment - Registrati on Review Mitigation for Propamocarb
hydrochloride
Product Name: PREVICUR
EPA Registration Number: 264-678
Application Date: March 29, 2019 , July 9, 2018, and February 23, 2024
Decision Number: 560070
Dear Anne Pfleiger:
The Agency, in accordance with the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA),
as amended, has completed reviewing all the information submitted with your application to
support the Registration Review of the above referenced product in connection with the
Propamocarb hydrochloride Interim Decision, and has concluded that your submission is
acceptable. The label referred to above, submitted in connection with registration under FIFRA,
as amended, is acceptable.
Should you wish to add/retain a reference to the companys website on your label, then please
be aware that the website becomes labeling under the Federal Insecticide, Fungicide, and
Rodenticide Act and is subject to review by the Agency. If the website is false or misleading, the
product would be misbranded and unlawful to sell or distribute under FIFRA section 12(a)(1)(E).
40 CFR 156.10(a)(5) list examples of statements EPA may consider false or misleading. In
addition, regardless of whether a website is referenced on your products label, claims made on
the website may not substantially differ from those claims approved through the registration
process. Therefore, should the Agency find or if it is brought to our attention that a website
contains false or misleading statements or claims substantially differing from the EPA approved
registration, the website will be referred to the EPAs Office of Enforcement and Compliance
Assurance.
Page 2 of 2
EPA Reg. No. 264-678
Decision No. 560070
A stamped copy of your labeling is enclosed for your records. This labeling supersedes
all previously accepted labeling and must be used at your next label printing. You must
submit one copy of the final printed labeling before you release the product for
shipment with the new labeling. In accordance with 40 CFR 152.130(c), you may
distribute or sell this product under the previously approved labeling for 12 months
from the date of this letter. After 12 months, you may only distribute or sell this
product if it bears this new revised labeling or subsequently approved labeling. “To
distribute or sell” is defined under FIFRA section 2(gg) and its implementing regulation
at 40 CFR 152.3.
If you have any questions about this letter, please contact DeMariah Koger by phone at (202)-
566-2288, or via email at Koger.demariah@epa.gov.
S i n c e r e l y ,
Julie Javier, Team Leader
Risk Management and Implementation Branch 4
Pesticide Re-Evaluation Division
Office of Pesticide Programs
ENCLOSURE: Stamped label
1
PREVICUR® FLEX Fungicide
For Control of Diseases of Cucurbits Vegetables, Guava, Leafy Greens
Subgroup 4-16A, Lima Beans, Pepper and Eggplant Subgroups 8-10B and 8-10C,
Starfruit, Tomato subgroup 8-10A, Tuberous and Corm Vegetables Subgroup 1C.
ACTIVE INGREDIENT: Propamocarb hydrochloride, (Propyl [3-(dimethylamino)propyl]
carbamate monohydrochloride)*.............................................................................................. 66.5 %
OTHER INGREDIENTS:......................................................................................................... 33.5%
TOTAL: 100.0%
Contains 6.0 lbs. propamocarb hydrochloride active ingredient per gallon.
EPA Reg No. 264-678 EPA Est. No.
KEEP OUT OF REACH OF CHILDREN
CAUTION
For MEDICAL And TRANSPORTATION Emergencies ONLY Call 24 Hours A Day 1-800-334-7577
For PRODUCT USE Information, Call 1-866-99BAYER (1-866-992-2937)
See [Back][Side] Panel for First Aid Instructions and [Leaflet][Booklet] for Complete Precautionary Statements and
Directions for Use. (Note to reviewer: Location of additional precautionary statements, directions for use will vary
between those listed, depending on container type/size.)
FIRST AID
IF
SWALLOWED:
x Call a physician or Poison Control Center or doctor immediately for treatment
advice.
x Have person sip a glass of water if able to swallow.
x DO NOT induce vomiting unless told to do so by a poison control center or
doctor.
x DO NOT give anything by mouth to an unconscious person.
IF IN EYES: x Hold eye open and rinse slowly and gently with water for 15-20 minutes.
x Remove contact lenses, if present, after the first 5 minutes, then continue
rinsing eye.
x Call a poison control center or doctor for treatment advice.
IF ON SKIN OR
CLOTHING:
x Take off contaminated clothing.
x Rinse skin immediately with plenty of water for 15-20 minutes.
x Call a poison control center or doctor for treatment advice.
Have the product container or label with you when calling a poison control center or doctor or
going for treatment.
For MEDICAL Emergencies Call 24 Hours A Day 1-800-334-7577.
PROPAMOCARB
HYDROCLORIDE GROUP 28 FUNGICIDE
Aug 16, 2024
264-678
2
PRECAUTIONARY STATEMENTS
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
CAUTION
Harmful if swallowed or absorbed through skin. Causes moderate eye irritation. Avoid contact with
skin, eyes, or clothing. Prolonged or frequently repeated skin contact may cause allergic reactions in
some individuals. Wash hands before eating, drinking,chewing gum or using tobacco, or using the
toilet.
PERSONAL PROTECTIVE EQUIPMENT (PPE)
Applicators and other handlers must wear:
x Long sleeved shirt and long pants
x Waterproof gloves
x Shoes plus socks
User Safety Requirements
Follow manufacturers instructions for cleaning/maintaining PPE. If no such instructions for washables
exist, use detergent and hot water. Keep and wash PPE separately from other laundry.
ENGINEERING CONTROLS
When handlers use closed systems, enclosed cabs, or aircraft in a manner that meets the
requirements listed in the Worker Protection Standard (WPS) for agricultural pesticides [40 CFR
170.240(d)(4-6)], the handler PPE requirements may be reduced or modified as specified in the WPS.
Pilots must use an enclosed cab that meets the definition listed in the Worker Protection Standard for
agricultural pesticides [40 CFR 170.305].
User Safety Recommendations
Users should:
x Remove clothing/PPE immediately if pesticides get inside. Then wash and put on clean clothing.
x Remove PPE immediately after handling product. Wash outside of gloves before removing. As
soon as possible, wash thoroughly and change into clean clothing.
ENVIRONMENTAL HAZARDS
DO NOT apply directly to water, to areas where surface water is present, or to intertidal areas below
the high water mark. DO NOT contaminate water when disposing of equipment washwaters or
rinsate. DO NOT apply when weather conditions favor drift from the treated areas.
3
DIRECTIONS FOR USE
It is a violation of Federal law to use this product in a manner inconsistent with its labeling.
DO NOT apply this product in a way that will contact workers or other persons, either directly or
through drift. Only protected handlers may be in the area during application. For any requirements
specific to your State or Tribe, consult the agency responsible for pesticide regulation.
Restriction: Pilots must use an enclosed cab that meets the definition listed in the Worker Protection
Standard for agricultural pesticides [40 CFR 170.305].
AGRICULTURAL USE REQUIREMENTS
Use this product only in accordance with its labeling and with the Worker Protection Standard 40 CFR
Part 170. This Standard contains requirements for the protection of agricultural workers on farms,
forests, nurseries, and greenhouses, and handlers of agricultural pesticides. It contains requirements
for training, decontamination, notification, and emergency assistance. It also contains specific
instructions and exceptions pertaining to the stat ements on this label about personal protective
equipment (PPE) and restricted-entry interval. The requi rements of this box only apply to uses of this
product that are covered by the Worker Protection Standard.
DO NOT enter or allow worker reentry into treated area s during the restricted entry interval (REI) of
12 hours.
PPE required for early entry to treated areas that is permitted under the Worker Protection Standard
and that involves contact with anything that has been treated, such as plants, soil, or water, is:
x Coveralls
x Waterproof gloves
x Shoes plus socks
PRODUCT INFORMATION
For field applications, PREVICUR® FLEX FUNGICIDE can be used as a solo product or in tank-mixes
for certain diseases of Cucurbits, Guava, Leafy Greens Subgroup 4-16A, Lima Beans, Pepper and
Eggplant Subgroups 8-10B and 8-10C, Starfruit, Tomato subgroup 8-10A, and Tuberous and Corm
Vegetables Subgroup 1C. PREVICUR FLEX FUNGICIDE in a tank-mixture combines the systemic
action of propamocarb hydrochloride with the contact activity of the tank-mix partner to give protection
against late blight (Phytophthora infestans), early blight (Alternaria solani), downy mildews, and
Phytophthora fruit rots. In Tuberous and Corm Vegetables Subgroup 1C, a PREVICUR FLEX
FUNGICIDE tank-mixture will reduce the incidence of tuber blight caused by Phytophthora infestans
when used as part of a disease management program. PREVICUR FLEX FUNGICIDE can be
applied either as a broadcast or as an over the row banded application. Alternations with QoI (Group
11) containing fungicides are advised as a resistance management strategy. A PREVICUR FLEX
FUNGICIDE tank-mixture is an excellent disease control product combination when used according
to label directions for control of these diseases.
For greenhouse applications on cucurbits, leaf lettuce, peppers, and tomato, use PREVICUR FLEX
FUNGICIDE in rotation with other effective fungicides if available to control diseases caused by
Pythium and Phytophthora spp. during plant propagation and greenhouse production.
4
FUNGICIDE RESISTANCE MANAGEMENT
For resistance management, PREVICUR FLEX FUNGICIDE contains a Group 28 fungicide. Any
fungal population may contain individuals naturally resistant to PREVICUR FLEX FUNGICIDE and
other Group 28 fungicides. A gradual or total loss of pest control may occur over time if these
fungicides are used repeatedly in the same fields. Appropriate resistance-management strategies
should be followed.
To delay fungicide resistance, take one or more of the following steps:
x Rotate the use of PREVICUR FLEX FUNGICIDE or other Group 28 fungicides within a
growing season sequence with different groups that control the same pathogens.
x Use tank mixtures with fungicide from a different group that are equally effective on the target
pest when such use is permitted. Use at least the minimum application rate as labeled by the
manufacturer.
x Adopt an integrated disease management program for fungicide use that includes scouting,
uses historical information related to pesticide use, and crop rotation, and which considers host
plant resistance, impact of environmental conditions on disease development, disease
thresholds, as well as cultural, biological and other chemical control practices.
x Where possible, make use of predictive disease models to effectively time fungicide
applications. Note that using predictive models alone is not sufficient to manage resistance.
x Monitor treated fungal populations for resistance development.
x Contact your local extension specialist or certified crop advisor for any additional pesticide
resistance-management and/or IPM recommendations for specific crops and pathogens.
x For further information or to report suspected resistance contact Bayer CropScience at 1-866-
99BAYER (1-866-992-2937). You can also contact your pesticide distributor or university
extension specialist to report resistance.
APPLICATION INFORMATION
Begin applications when conditions are favorable for disease, but before infection, according to the
use directions below.
MIXING THE SPRAY
It is the pesticide user's respons ibility to ensure that all products are registered for the intended use.
Read and follow the applicable restrictions and limi tations and directions for use on all product labels
involved in tank mixing. Users must follow the most restrictive directions for use and precautionary
statements of each product in the tank mixture.
Follow the directions of your State Cooperative Extension Service for tank mixing with wettable
powders, emulsifiable concentrates, suspension concentrates, or flowables. Add one-half of the
required amount of water to the spray or mixing t ank and start agitation. Add the required quantity of
PREVICUR FLEX FUNGICIDE and the tank-mix partner to the water and complete filling with water
to the required total volume. Maintain agitation throughout spraying. DO NOT allow spray mixture to
remain in the tank overnight, or for long periods during the day without agitation.
Consult the intended tank-mix partner product label for appropriate application rates and use
instructions. Follow the label direct ions for the most restrictive of label precautions and limitations.
This product may not be mixed with any product c ontaining a label prohibition against such mixing.
Read and observe the most restrictive precautiona ry statements and other information appearing on
product labels used in mixtures.
5
Banded Applications:
Seed potatoes can be a significant primary source of late blight, and an early fungicide application
can minimize this threat. In othe r crops, infected transplants or unusual weather conditions may
increase the threat of disease when the plants are small. PREVICUR FLEX FUNGICIDE may be
applied as an early season post-emergence banded application. When applying PREVICUR FLEX
FUNGICIDE in a band, DO NOT concentrate the dose rate in the banded area. Thorough coverage of
the plants is essential for optimum disease control; therefore adjust the bandwidth depending on plant
height or size. Repeated applications will result in improved disease control.
When using a banded application, the actual amount of PREVICUR FLEX FUNGICIDE applied will be
proportionately less than what would be applied with a broadcast spray. Use the following formula to
calculate the amount of PREVICUR FLEX FUNGICIDE needed per crop acre when making band
applications. Apply band applications of PREVICUR FLEX FUNGICIDE in a minimum of 5 gallons of
water per acre.
Band width in
inches
X Broadcast rate
(pts./acre)
= Amount needed per acre of field
in pts./A.
Row spacing in
inches
Broadcast Applications:
Using ground spray equipment, apply PREVICUR FLEX FUNGICIDE at the rates specified below.
Thorough uniform coverage is essential for dise ase control. Apply a PREVICUR FLEX FUNGICIDE
tank-mixture in a minimum of 15 gallons of water per acre. Apply as a foliar spray in sufficient water to
obtain thorough coverage. With moderate to heavy di sease pressure, use the shorter spray intervals.
Check with your local Cooperative Extension Service if you are unsure about whether these
conditions exist.
Aerial Applications:
Apply PREVICUR FLEX FUNGICIDE at the rates specif ied below using fixed wing or rotary aircraft
equipment in a minimum of 5 gallons of water per a cre unless otherwise directed under specific crop
labeling. Thorough uniform coverage is essential for disease control.
SPRAY DRIFT ADVISORIES
THE APPLICATOR IS RESPONSIBLE FOR AVOIDING OFF-SITE SPRAY DRIFT.
BE AWARE OF NEARBY NON-TARGET SITES AND ENVIRONMENTAL CONDITIONS.
IMPORTANCE OF DROPLET SIZE
An effective way to reduce spray drift is to apply large droplets. Use the largest droplets that provide
target pest control. While applying larger droplets will reduce spray drift, the potential for drift will be
greater if applications are made improperly or under unfavorable environmental conditions.
Controlling Droplet Size Ground Boom
x Volume - Increasing the spray volume so that larger droplets are produced will reduce spray
drift. Use the highest practical spray volume for the application. If a greater spray volume is
needed, consider using a nozzle with a higher flow rate.
x Pressure - Use the lowest spray pressure recommended for the nozzle to produce the target
spray volume and droplet size.
x Spray Nozzle - Use a spray nozzle that is designed for the intended application. Consider
using nozzles designed to reduce drift.
6
Controlling Droplet Size Aircraft
x Adjust Nozzles - Follow nozzle manufacturers recommendations for setting up nozzles.
Generally, to reduce fine droplets, nozzles should be oriented parallel with the airflow in flight.
BOOM HEIGHT Ground Boom
For ground equipment, the boom should remain level with the crop and have minimal bounce.
RELEASE HEIGHT - Aircraft
Higher release heights increase the potential for spray drift.
BOOMLESS GROUND APPLICATIONS
Setting nozzles at the lowest effective height will help to reduce the potential for spray drift.
SHIELDED SPRAYERS
Shielding the boom or individual nozzles can reduce spray drift. Consider using shielded sprayers.
Verify that the shields are not interfering with the uniform deposition of the spray on the target area.
HANDHELD TECHNOLOGY APPLICATIONS
Take precautions to minimize spray drift.
TEMPERATURE AND HUMIDITY
When making applications in hot and dry conditions, use larger droplets to reduce effects of
evaporation.
TEMPERATURE INVERSIONS
Drift potential is high during a temperature inversion. Temperature inversions are characterized by
increasing temperature with altitude and are common on nights with limited cloud cover and light to
no wind. The presence of an inversion can be indicated by ground fog or by the movement of smoke
from a ground source or an aircraft smoke generator. Smoke that layers and moves laterally in a
concentrated cloud (under low wind conditions) indicates an inversion, while smoke that moves
upward and rapidly dissipates indicates good vertical air mixing. Avoid applications during
temperature inversions.
WIND
Drift potential generally increases with wind speed. AVOID APPLICATIONS DURING GUSTY WIND
CONDITIONS.
Applicators need to be familiar with local wind patterns and terrain that could affect spray drift.
APPLICATION THROUGH IRRIGATION SYSTEMS
Apply this product only through center pivot, mo torized-lateral move, traveling gun, solid set or
portable (wheel move, side roll, end tow, or hand move) and drip irrigation systems. PREVICUR
FLEX FUNGICIDE may also be applied by drip irrigati on or rock wool/nutrient solution systems in the
greenhouse. DO NOT apply this product through any other type of irrigation system. Crop injury, lack
of effectiveness, or illegal pesticide residues in the crop can result from non-uniform distribution of
treated water. If you have questions about calibrat ion, contact State Extension Service specialists,
equipment manufacturers or other experts. A perso n knowledgeable of the chemigation system and
responsible for its operation or under the supervision of the responsible person, must shut the system
down and make necessary adjustments if the need arise. With the exception of Tuberous and Corm
7
Vegetables Subgroup 1C, PREVICUR FLEX FUNGICIDE has not been sufficiently tested when
applied through irrigation systems to ensure consisten t product performance for all labeled uses. The
following application techniques are provided for user reference but DO NOT constitute a warranty of
fitness for application through sprinkler or drip ir rigation equipment. Users must check with state and
local regulatory agencies for potential use restrict ions before applying any agricultural chemical
through sprinkler or drip irrigation equipment.
DO NOT connect an irrigation system (including greenhouse systems) used for pesticide application
to a public water system, unless the pesticide label prescribed sa fety devices for public water
systems are in place. Public water system' means a system for th e provision to the public of piped
water for human consumption if such system has at least 15 service connections or regularly serves
an average of at least 25 individuals daily at le ast 60 days out of the year. Chemigation systems
connected to public water systems must contain a functional, reduced-pressure zone, back flow
preventer (RPZ) or the functional equivalent in the water supply line upstream from the point of
pesticide introduction. As an option to the RPZ, th e water from the public water system must be
discharged into a reservoir tank prior to pestic ide introduction. There must be a complete physical
break (air gap) between the flow outlet end of the fill pipe and the top or overflow rim of the reservoir
tank of at least twice the inside diameter of the fill pipe. The pesticide injection pipeline must contain a
functional, automatic, quick-closing check valve to prevent the flow of fluid back toward the injection
pump. Pesticide injection pipeline must contain a functional, normally closed, solenoid-operated valve
located on the intake side of the injection pump and connected to the system interlock to prevent fluid
from being withdrawn from the su pply tank when the irrigation system is either automatically or
manually shut down. The systems must contain functi onal interlocking controls, to automatically shut
off the pesticide injection pump when the water pump motor stops or in cases where there is no water
pump, when the water pressure decreases to the point where pesticide distribution is adversely
affected. Systems must use a metering pump, for example a positive displacement injection pump
(e.g., diaphragm pump) effectively designed and cons tructed of materials that are compatible with
pesticides and capable of being fitted with a system interlock.
DO NOT apply when wind speed favors drift beyond the area intended for treatment. Spray mixture in
the chemical supply tank must be agitated at all times, otherwise settling and uneven application may
occur. Apply pesticide continuously for the duration of the water application. For mixing instructions,
please refer to specific use directions in the “Application Directions” section.
This product may be used through two basic types of irrigation systems as outlined in Sections A
and B below. The system must contain a functional check valve, vacuum relief valve, and low-
pressure drain appropriately located on the irrigation pipeline to prevent water source contamination
from back flow. Determine which type of irrigation system is in place, then refer to the appropriate
directions provided below for each type. See crops section on the label for listed treatment rates and
additional use information.
A. Center Pivot, Motorized-Lateral Move and Traveling Gun Irrigation Equipment
For injections of pesticides, these continuously moving systems must use a positive displacement
injection pump of either diaphragm or piston type an d be constructed of materials that are compatible
with pesticides. They must also be capable of being fitted with a system interlock and capable of
injection at pressures approximately 2-3 times thos e encountered within the irrigation water line.
Venturi applicator units cannot be used on these systems. Thoroughly mix the specified amount of
this product for acreage to be co vered into same amount of water used during calibration and inject
into system continuously for one revolution or run. Mixture in the chemical supply tank must be
continuously agitated during the injection run. Shut off injection equipment after one revolution or run,
but continue to operate irrigation system until this product has been cleared from last sprinkler head.
8
B. Solid-Set, Portable (Wheel Move, Side Roll, End Tow, or Hand Move) and Drip Irrigation
Equipment
With stationary systems, an effectively designed in-li ne Venturi applicator unit is preferred to support
even and quick distribution. However, a positive-dis placement pump can also be used. For solid set
systems, determine acreage covered by sprinkler. Fill the tank of injection equipment with water and
adjust flow to use contents over 30 to 45 minutes. Mix specified amount of this product for acreage to
be covered with water so that the total mixture of th is product plus water in the injection tank is equal
to the quantity of water used during calibration. Operate entire system at normal pressures specified
by the manufacturer of injection equipment used, for am ount of time established during calibration.
This product can be injected during the irrigation cycl e or as a separate application. For drip irrigation
systems, introduce PREVICUR FLEX FUNGICIDE into irrigation solution for a period sufficient to
distribute the product uniformly in the crop, and PREVICUR FLEX FUNGICIDE must be added near
the end of the normal irrigation cycle so that subseque nt watering will not flush the product from the
root zone. Stop injection equipment with any system after treatment is completed and continue to
operate irrigation system until this product has been cl eared from last sprinkler head or drip irrigation
line. Greenhouses must be constructed of materials that are compatible with pesticides.
COMPATIBILITY
PREVICUR FLEX FUNGICIDE is compatible with most commonly used fungicide, herbicide,
insecticide, and foliar nutrient products. Howev er, the physical compatibility of PREVICUR FLEX
FUNGICIDE with all potential tank-mix partners has not been fully investigated. If tank mixing with
other pesticides is desirable, conduct a jar te st with the volumes and rates typically used in
agricultural application. Using a small containe r of water, add the proportionate amounts of the
products: wettable powders and water-dispersible gran ular products first, then liquid flowables and
emulsifiable concentrates last. After thoroughly mixing , let stand for at least 15 minutes. Look for
signs of separation, globules, sludge, flakes, or other precipitates. Physical compatibility is indicated if
the combination remains mixed or can be remixed readily. THE CROP SAFETY OF ALL POTENTIAL
TANK-MIXES WITH PREVICUR FLEX FUNGICIDE, INCLUDING ADDITIVES AND OTHER
PESTICIDES HAS NOT BEEN TESTED ON ALL CROPS. BEFORE APPLYING ANY TANK-
MIXTURE NOT SPECIFICALLY LISTED ON THIS LA BEL, SAFETY TO THE TARGET CROP(S)
MUST BE CONFIRMED.
CROP ROTATION RESTRICTIONS
Crops on this label may be rotated anytime, following the last application of PREVICUR FLEX
FUNGICIDE. DO NOT rotate to root and leafy vegetables for 30 days following the last application of
PREVICUR FLEX FUNGICIDE. DO NOT rotate to winter wheat and all other crops NOT on this label
for 120 days following the last application of PREVICUR FLEX FUNGICIDE.
9
CROP USE DIRECTION
CUCURBIT VEGETABLES, GROUP 9
Chayote (fruit); Chinese waxgourd (Chinese preservi ng melon); citron melon; cucumber; gherkin;
gourd, edible (includes hyotan, cucuzza, hechima, Chinese okra); Momordica spp (includes balsam
apple, balsam pear, bittermelon, Chinese cucumber); muskmelon (includes true canteloupe,
cantaloupe, casaba, crenshaw melon, golden pershaw melon, honeydew melon, honey balls, mango
melon, Persian melon, pineapple melon, Santa Claus melon, and snake melon); pumpkin; squash,
summer (includes crookneck squash, scallop squash, straightneck squash, vegetable marrow,
zucchini); squash, winter (includes butternut sq uash, calabaza, hubbard squash, acorn squash,
spaghetti squash); watermelon.
Apply preventatively as a foliar spray in sufficien t water to obtain thorough coverage. PREVICUR
FLEX FUNGICIDE may be applied through chemigation (including drip and transplant/setting water),
see APPLICATION THROUGH IRRIGATION SYSTEMS above. PREVICUR FLEX FUNGICIDE may
be used in a tank-mix with other fungicides regi stered for the control of downy mildew. See
Compatibility section.
Disease
PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Downy mildew
(Pseudoperonospo
ra cubensis)
Phytophthora
blight:
Suppression only
(Phytophthora
capsici
)
1.2
(0.9 lbs
Propamocarb/A)
or
0.6 1.2
(0.45-0.9 lbs
Propamocarb/A)
+
Tank-mix partner
Use PREVICUR FLEX FUNGICIDE as a foliar spray in a
preventive program. Begin applications when conditions
are favorable for disease, but before infection. Continue
on 7-14 day intervals until the threat of disease is over.
For Phytophthora capsici suppression, ground application
must be made with a tractor-mounted boom sprayer
equipped with three nozzles per row with two nozzles
directed to ensure thorough coverage of the lower portion
of the plants.
When applying PREVICUR FLEX FUNGICIDE at intervals
longer than 7 days, alternate with an application of a
contact fungicide midway between PREVICUR FLEX
FUNGICIDE applications. With moderate to heavy
disease pressure the shorter spray intervals must be
used. Check with your local Cooperative Extension
Service if you are unsure about whether these conditions
exist.
Pythium root rots
and seedling
diseases (Pythium
spp.)
1.2
(0.9 lbs
Propamocarb/A)
PREVICUR FLEX FUNGICIDE can be applied by directed
nozzles to the lower portion of the plants and surrounding
soil, or via drip irrigation, transplant/setting water, or by
sprinklers.
Restrictions
x Maximum single use rate: 1.2 Pints/acre (0.9 lbs Propamocarb/A).
x Minimum reapplication interval: 7 days.
x Regardless of rate, do not exceed 2 applications per crop cycle.
10
x Do not use on more than 4 crop cycles per acre per year.
x DO NOT apply more than 6 pints of PREVICUR FLEX FUNGICIDE (4.5 lbs. total a.i.) per acre
per year.
x DO NOT apply within 2 days of harvest for cucurbits.
x When used at 1.2 pints/acre (0.9 lbs Propamocarb/A), DO NOT exceed 5 applications of
Previcur Flex Fungicide per year. When used at 0.6 pints per acre (0.45 lb Propamocarb/A), DO
NOT exceed 8 applications per year.
GUAVA[1]
Disease PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Pythium root rot
(Pythium spp.)
2.0
(1.5 lbs
Propamocarb/A)
Apply PREVICUR FLEX FUNGICIDE as soil directed
spray application under the tree canopy in a minimum of
80 gallons per acre. Begin applications when conditions
are favorable for disease, but before infection. Follow with
a second application after a minimum interval of 30 days.
Application requires irrigation immediately after the
application (within 6 hours) with one half (1/2) to one third
(1/3) inch of water to properly move the PREVICUR FLEX
FUNGICIDE into the root zone.
Irrigation can be done as overhead sprinkler irrigation or
garden hose drench to the drip line.
Note that the treated area for directed applications is
calculated as row spacing X number of rows X plot length.
Restrictions
x Maximum single use rate: 2 Pints/acre (1.5 lbs Propamocarb/A).
x Minimum reapplication interval: 30 days
x Maximum number of applications per year: 2
x DO NOT apply more than 4 pints of PREVICUR FLEX FUNGICIDE (3.0 lbs. total a.i.) per acre
per year
x DO NOT apply within 1 day of harvest.
x [1Not for use in CA without a supplemental label.]
11
LEAFY GREENS SUBGROUP 4-16A
Amaranth, Chinese; amaranth, leafy; aster, Indian; blackjack; cats whiskers; cham -chwi; cham-na-
mul; chervil, fresh leaves; chipilin; chrysanthemu m, garland; cilantro, fresh leaves; corn salad;
cosmos; dandelion, leaves; dang-gwi, leaves; dill weed; dock; dol-nam-mul; ebolo; endive; escarole;
fameflower; feather cockscomb; good king henry; huauz ontle; jute, leaves; lettuce, bitter; lettuce,
head; lettuce, leaf; orach; parsley, fresh leaves; plantain, buckhorn; primrose, English; purslane,
garden; purslane, winter; radicchio; spinach; spinach, Malabar; spinach, New Zealand; spinach,
tanier; Swiss chard; violet, Chinese, leaves; cultivars, varieties, and hybrids of these commodities.
Apply preventatively as a foliar spray in sufficient water to obtain thorough coverage. Ground
application may be made with a tractor-mounted boo m sprayer equipped with three nozzles per row
with two nozzles directed to ensure thorough coverage of the lower portion of the plants and the
surrounding soil surface. PREVICUR FLEX FUNGICIDE may be applied through chemigation
(including drip and transplant/setting water), see APPLICATION THROUGH IRRIGATION SYSTEMS
above. PREVICUR FLEX FUNGICIDE may also be used in a tank-mix with other fungicides
registered for the control of downy mildew. See Compatibility section.
Disease
PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Downy mildew
(Bremia lactucae)
2.0
(1.5 lbs
Propamocarb/A)
or
1.33 2.0
(0.9975-1.5 lbs
Propamocarb/A)
+
Tank-mix partner
Make foliar applications when conditions first become
favorable for disease development (for example, high
moisture and moderate temperature), but before infection.
Continue applications on a 7-10 day interval until threat of
disease is over.
Use PREVICUR FLEX FUNGICIDE on a 5-day schedule if
signs of infection are present and conditions are favorable
for disease development. Check with your local
Cooperative Extension Service if you are unsure about
whether these conditions exist.
For aerial applications use a minimum of 10 gallons of
spray.
Pythium root rots
and seedling
diseases (Pythium
spp.)
2.0
(1.5 lbs
Propamocarb/A)
PREVICUR FLEX FUNGICIDE can be applied by directed
nozzles to the lower portion of the plants and surrounding
soil, or via drip irrigation, in transplant/setting water, or by
sprinklers.
Restrictions
x Maximum single use rate: 2.0 Pints/acre (1.5 lbs Propamocarb/A).
x Minimum reapplication interval: 5 days
x Regardless of rate, do not exceed 2 applications per crop cycle.
x Do not use on more than 4 crop cycles per acre per year.
x DO NOT apply more than 8 pints of PREVICUR FLEX FUNGICIDE (6.0 lbs. total a.i.) per acre
per year.
x DO NOT apply within 2 days of harvest for leafy greens subgroup 4-16A.
x When used at 2.0 pints/acre (1.5 lbs Propamocarb/A), DO NOT exceed 4 applications of
12
Previcur Flex Fungicide per year. When used at 1.33 pints/acre (0.9975 lbs Propamocarb/A),
DO NOT exceed 6 applications per year.
LIMA BEANS
(For Use East of the Rocky Mountains Only)
Apply preventatively as a foliar spray in sufficient water to obtain thorough coverage. PREVICUR
FLEX FUNGICIDE may be applied through chemigation (including drip and transplanting/setting
water), see APPLICATION THROUGH IRRIGATION SYSTEMS section.
Disease
PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Downy mildew
(Phytophthora
phaesoli)
2.0
(1.5 lbs
Propamocarb/A)
Make foliar applications when conditions first become
favorable for disease development, but before
infection. Continue applications on a 7
-day interval until
threat of disease is over.
Pod rot
(Phytophthora
capsici)
(suppression)
1.2 2.0
(0.9-1.5 lbs
Propamocarb/A)
Make foliar applications when conditions first become
favorable for disease development, but before
infection. Continue applications on a 7
-day interval until
threat of disease is over.
Pythium root rots
and seedling
diseases
(Pythium spp.)
2.0
(1.5 lbs
Propamocarb/A)
PREVICUR FLEX FUNGICIDE can be applied by
directing nozzles to the lower portions of the plants and
surrounding soil, or via drip irrigation, transplant/setting
water, or by sprinklers.
Restrictions
x Maximum single use rate: 2.0 Pints/acre (1.5 lbs Propamocarb/A).
x Minimum reapplication interval: 7 days
x Regardless of rate, do not exceed 2 applications per crop cycle.
x Do not use on more than 4 crop cycles per acre per year.
x DO NOT apply more than 8 pints of PREVICUR FLEX FUNGICIDE (6.0 lbs. total a.i.) per acre
per year.
x DO NOT harvest within 12 hours of the last application of PREVICUR FLEX FUNGICIDE.
x When used at 2.0 pints/acre (1.5 lbs Propamocarb/A), DO NOT exceed 4 applications of
Previcur Flex Fungicide per year. When used at 1.2 pints/acre (0.9 lbs Propamocarb/A), DO
NOT exceed 6 applications per year.
13
FRUITING VEGETABLES 8-10
TOMATO SUBGROUP 8-10A
Bush tomato; cocona; currant tomato; garden hu ckleberry; goji berry; groundcherry; naranjilla;
sunberry; tomatillo; tomato; tree tomato; cultivars, varieties, and/or hybrids of these
PREVICUR FLEX FUNGICIDE mixed with chlorothalonil , maneb, or mancozeb is an excellent tank-
mix combination for control of late blight ( Phytophthora infestans) and early blight ( Alternaria solani).
Follow use directions and rates specified for lat e blight control. PREVICUR FLEX FUNGICIDE may
be applied through chemigation (including drip and transplant/setting water), see APPLICATION
THROUGH IRRIGATION SYSTEMS above. Always cons ult your agricultural advisor, University
contact, or Extension Service for directed pest management practices for your area.
Disease
PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Late blight
(Phytophthora
infestans)
Early blight
(Alternaria solani)
0.7-1.5
(0.525-1.125 lbs
Propamocarb/A)
+
Tank-mix partner
Apply on a 10 day interval. The low rate and longer spray
interval may be used early in the season before canopy
closure when disease pressure may be light. After canopy
closure switch to the higher rate and use the shorter
intervals.
Pythium root rots
and seedling
diseases (Pythium
spp.)
1.5
(1.125 lbs
Propamocarb/A)
PREVICUR FLEX FUNGICIDE can be applied by directed
nozzles to the lower portions of the plants and
surrounding soil, or via drip irrigation, transplant/setting
water, or by sprinklers.
Restrictions
x Maximum single use rate: 1.5 pints/acre (1.125 lbs Propamocarb/A).
x Minimum reapplication interval: 10 days
x Regardless of rate, do not exceed 2 applications per crop cycle.
x Do not use on more than 4 crop cycles per acre per year.
x DO NOT apply more than 7.5 pints of PREVICUR FLEX FUNGICIDE (5.625 lbs. total a.i.) per
acre per year.
x DO NOT apply within 5 days of harvest.
x When used at 1.5 pints/acre (1.125 lbs Propamocarb/A), DO NOT exceed 5 applications of
Previcur Flex Fungicide per year. When used at 0.7 pints/acre (0.525 lbs Propamocarb/A), DO
NOT exceed 8 applications per year.
14
PEPPER AND EGGPLANT SUBGROUPS 8-10B AND 8-10C
African eggplant; bell pepper; eggplant; martynia; okra; pea eggplant; pepino; non-bell pepper;
roselle; scarlet eggplant; cultivars, varieties, and/or hybrids of these.
Apply preventatively as a foliar spray in sufficien t water to obtain thorough coverage. PREVICUR
FLEX FUNGICIDE may be applied through chemigation (including drip and transplant/setting water),
see APPLICATION THROUGH IRRIGATION SYSTEMS above.
Disease PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Phytophthora
blight:
Suppression only
(Phytophthora
capsici
)
1.2
(0.9 lbs
Propamocarb/A)
Use PREVICUR FLEX FUNGICIDE as a foliar spray in a
preventive program. Begin applications when conditions
are favorable for disease, but before infection. Continue
on 7
-14 day intervals until the threat of disease is over.
When applying PREVICUR FLEX FUNGICIDE at intervals
longer than 7 days, alternate with an application of a
contact fungicide midway between PREVICUR FLEX
FUNGICIDE applications.
For
Phytophthora capsici suppression, ground application
must be made with a tractor-mounted boom sprayer
equipped with three nozzles per row with two nozzles
directed to ensure thorough coverage of the lower portion
of the plants.
With moderate to heavy disease pressure use shorter
specified spray intervals. Check with your local
Cooperative Extension Service if you are unsure about
whether these conditions exist.
Pythium root rots
and seedling
diseases (Pythium
spp.)
1.2
(0.9 lbs
Propamocarb/A)
PREVICUR FLEX FUNGICIDE can be applied by directed
nozzles to the lower
portions of the plants and
surrounding soil, or via drip irrigation, transplant/setting
water, or by sprinklers.
Restrictions
x Maximum single use rate: 1.2 pints/acre (0.9 lbs Propamocarb/A).
x Minimum reapplication interval: 7 days
x Regardless of rate, do not exceed 2 applications per crop cycle.
x Do not use on more than 4 crop cycles per acre per year.
x DO NOT apply more than 6 pints of PREVICUR FLEX FUNGICIDE (4.5 lbs. total a.i.) per acre
per year.
x DO NOT apply within 5 days of harvest.
x DO NOT exceed 5 applications of Previcur Flex Fungicide per year.
15
STARFRUIT[1]
Disease PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Pythium root rot
(Pythium spp.)
2.0
(1.5 lbs
Propamocarb/A)
Apply PREVICUR FLEX FUNGICIDE as soil directed
spray application under the tree canopy in a minimum of
80 gallons per acre. Begin applications when conditions
are favorable for disease, but before infection. Follow with
a second application after a minimum interval of 30 days.
Application requires irrigation immediately after the
application (within 6 hours) with one half (1/2) to one third
(1/3) inch of water to properly move the PREVICUR FLEX
FUNGICIDE into the root zone.
Irrigation can be done as overhead sprinkler irrigation or
garden hose drench to the drip line.
Note that the treated area for directed applications is
calculated as row spacing X number of rows X plot length.
Restrictions
x Maximum single use rate: 2 Pints/acre (1.5 lbs Propamocarb/A).
x Minimum reapplication interval: 30 days
x Maximum number of applications per year: 2
x DO NOT apply more than 4 pints of PREVICUR FLEX FUNGICIDE (3.0 lbs. total a.i.) peracre
per year
x DO NOT apply within 1 days of harvest.
x [1Not for use in CA without a supplemental label.]
16
TUBEROUS AND CORM VEGETABLES SUBGROUP 1C
Arracacha; arrowroot; artichoke, Chinese; artichoke, Jerusalem; canna, edible; cassava, bitter and
sweet; chayote (root); chufa; dasheen (taro); ginger; leren; potato; sweet potato; tanier; turmeric; yam
bean; yam, true.
PREVICUR FLEX FUNGICIDE mixed with chlorothalonil , maneb, or mancozeb is an excellent tank-
mix combination for control of late blight ( Phytophthora infestans) and early blight ( Alternaria solani).
Follow use directions and rates specified for late bli ght. When the threat of early blight is moderate to
severe, then additional amounts of the tank-m ix partner are needed. Read and follow the use
directions on the tank-mix partner label. PREVICUR FLEX FUNGICIDE may be applied through
chemigation, see APPLICATION THROUG H IRRIGATION SYSTEMS above. Tuber blight
suppression will result as a consequence of good foliar blight control, complete killing of vines before
harvest, and proper tuber storage conditions. Always consult your agricultural advisor, University
contact, or Extension Service for directed pest management practices for your area.
Disease
PREVICUR FLEX
FUNGICIDE
(Pints per Acre)
Applications Instructions
Late blight
(Phytophthora
infestans)
Early blight
(Alternaria solani)
0.7-1.2
(0.525-0.9 lbs
Propamocarb/A)
+
Tank-mix partner
Apply on a 7-10 day interval. The low rate and longer
spray interval may be used early in the season before
canopy closure when disease pressure may be light. After
canopy closure switch to the higher rate and use the
shorter intervals.
Restrictions
x Maximum single use rate: 1.2 pints/acre (0.9 lbs Propamocarb/A).
x Minimum reapplication interval: 7 days
x When applied at the lower single use rate of 0.7 pints per acre (0.525 lbs Propamocarb/A), DO
NOT exceed 8 applications per acre per year, and for applications made at the upper single use
application rate of 1.2 pints per acre (0.9 lbs Propamocarb/A), do not exceed 5 applications per
acre per year.
x DO NOT apply more than 6.0 pints of PREVICUR FLEX FUNGICIDE (4.5 lbs. total a.i.) per acre
per year.
x DO NOT apply within 14 days before harvest.
x For aerial application, apply a minimum of 6 gallons of spray mixture per acre to assure uniform
coverage.
17
GREENHOUSE USE
Apply PREVICUR FLEX FUNGICIDE to greenhouse cucurbits, leaf lettuce, peppers and tomatoes for
prevention of root rot and damping-off caused by Pythium spp. and Phytophthora spp. PREVICUR
FLEX FUNGICIDE requires no agitation after initial mi xing and is effective at all stages of plant
propagation and development including seeding, transplanting and potting. Stock solutions of
PREVICUR FLEX FUNGICIDE must be used within one day of mixing. DO NOT mix with other
products. Prevent intense sunlight after applic ation by applying PREVICUR FLEX FUNGICIDE in the
evening. DO NOT apply PREVICUR FLEX FUNGICIDE to dry rockwool or other growing media
without first pre-wetting with water. Phytotoxicit y may occur if PREVICUR FLEX FUNGICIDE is
applied directly to dry growing media, especially in intense sunlight.
GREENHOUSE APPLICATION Cucurbits, Leaf Lettuce, Peppers and Tomato
.
USE PATTERN USE DIRECTIONS
PRESEEDING
AND/OR SEEDLING
TREATMENT
(before transplanting)
ROCK WOOL CUBE SATURATION1:
Prepare a 1:1000 stock solution ( for example - 12.8 fl. oz. product in 100
gallons water). Apply as a drench to pre- wet cubes at a rate of 3.4 fl. oz.
(100 ml) to 6.8 fl. oz. (200 ml) stock solution per cube to saturate. (100
gallons applied properly will treat 3800 to 1900 plants, respectively).
SEED BEDS SOIL or SOILLESS2:
In a minimum of 50 gallons water/1000 sq. ft apply:
At seeding 32 fl. oz. product/1000 sq. ft. (1.5 lbs. a.i./1000 sq. ft).
After emergence for food production - 16 fl. oz. product/1000 sq. ft.
(0.75 lbs. a.i./1000 sq. ft).
GREENHOUSE
TREATMENT
(after transplanting)
DRIP SYSTEM or SOIL DRENCH1:
Prepare a 1:1000 stock solution (for example - 12.8 fl. oz. product in 100
gallons water). For the first two weeks after transplanting, apply through
drip system at a rate of 3.4 fl. oz. (100 ml) stock solution per cube to
avoid runoff and cover root area. After 2 weeks, apply through drip
system at a rate of 3.4 fl. oz. (100 ml) to 6.8 fl. oz. (200 ml) stock solution
per cube. (100 gallons applied properly will treat 3800 to 1900 plants,
respectively).
Evening applications of PREVICUR FLEX FUNGICIDE by drip irrigation
will reduce leaching or washing of the product from the root zone and
may result in improved control. See statements in the “How to Use”
section above regarding potential phytotoxicity.
FOLIAR TREATMENT (leaf lettuce only)3:
See foliar field use direction according to crop of interest on this label.
DO NOT harvest for 2 days after greenhouse foliar treatment.
18
MAXIMUM USE
RATES
NUMBER OF
PLANTS
PER ACRE
AMOUNT PRODUCT PER
APPLICATION PER ACRE
AMOUNT PRODUCT PER
CROPPING CYCLE
6,000
10,000
14,000
41.3 fl. oz. (1.94 lbs. a.i./A)
68.8 fl. oz. (3.23 lbs. a.i./A)
96.4 fl. oz. (4.52 lbs. a.i./A)
248 fl. oz. (11.6 lbs. a.i./A)
413 fl. oz. (19.4 lbs. a.i./A)
578 fl. oz. (27.1 lbs. a.i./A)
RESTRICTIONS
x Minimum reapplication interval: Tomato 7 days, Leaf Lettuce 5 days, Cucurbits 7 days,
Peppers 7 days
x Maximum yearly rate: for 6,000 plants per acre: 248 fl oz/acre (11.6 lbs. a.i./A); for 10,000
plants per acre: 413 fl oz/acre (19.4 lbs. a.i./A); for 14,000 plants per acre: 578 fl oz/acre
(27.1 lbs. a.i./A)
x Maximum number of applications per year: 6
x Do not apply more than 4 total applications after transplanting per cropping cycle.
1 Maximum single use rate: for 6,000 plants per acre: 41.3 fl oz/acre (1.94 lbs. a.i./A); for 10,000
plants per acre: 68.8 fl oz/acre (3.23 lbs. a.i./A); for 14,000 plants per acre: 96.4 fl oz/acre (4.52 lbs.
a.i./A)
2 DO NOT apply more than 2 preseeding and/or seedling applications per cropping cycle (max
single 1.5 lbs. a.i./1000 sq. ft. and max per crop cycle 2.25 lbs. a.i./1000 sq. ft )
3 For transplant production and greenhouse production (leaf lettuce only), DO NOT apply more than
2 foliar applications per cropping cycle with a minimum of 1 days before the transplants are set to
leave the greenhouse (max single 1.5 lbs. a.i./A and max per crop cycle leaf lettuce 3.0 lbs a.i./A).
For greenhouse production, DO NOT harvest for 2 days after greenhouse foliar treatment (2-day
PHI).
19
STORAGE AND DISPOSAL
DO NOT contaminate water, food, or feed by storage or disposal.
STORAGE: Store in original container and keep tightly closed. Store in a cool dry place.
PESTICIDE DISPOSAL: Pesticide wastes are toxic. Improper disposal of excess pesticide, pesticide
spray, or rinsate is a violation of federal law. If these wastes cannot be disposed of by use according
to label directions, contact your State Pesticide or Environmental Control Agency, or the Hazardous
Waste representative at the nearest EPA Regional Office for guidance.
CONTAINER HANDLING
[Non-Refillable Containers]
Rigid, Non-refillable containers (equal to or less than 5 gallons)
Non-refillable container. DO NOT reuse or refill this container. Triple rinse or pressure rinse container
(or equivalent) promptly after emptying. Triple rinse as follows: Empty the remaining contents into
application equipment or a mix tank and drain for 10 seconds after the flow begins to drip. Fill the
container 1/4 full with water and recap. Shake for 10 seconds. Pour rinsate into application equipment
or a mix tank or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to
drip. Repeat this procedure two more times.
Pressure rinse as follows: Empty the remaining contents into application equipment or a mix tank and
continue to drain for 10 seconds after the flow begins to drip. Hold container upside down over
application equipment or mix tank or collect rinsate for later use or disposal. Insert pressure rinsing
nozzle in the side of the container, and rinse at about 40 PSI for at least 30 seconds. Drain for 10
seconds after the flow begins to drip.
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill
or by incineration.
Rigid Non-refillable Containers that are too large to shake (i.e., with capacities greater than 5
gallons or 50 lbs)
Non-refillable container. DO NOT reuse or refill this container. Refer to Bottom Discharge IBC or Top
Discharge IBC, Drums, Kegs information as follows.
Bottom Discharge IBC (e.g. Schuetz Caged IBC or Snyder Square Stackable)
Pressure rinsing the container before final disposal is the responsibility of the person disposing of the
container. To pressure rinse the container before final disposal, empty the remaining contents from
the IBC into application equipment or mix tank. Raise the bottom of the IBC by 1.5 inches on the side
which is opposite of the bottom discharge valve to promote more complete product removal.
Completely remove the top lid of the IBC. Use water pressurized to at least 40 PSI to rinse all interior
portions. Continuously pump or drain rinsate into application equipment or rinsate collection system
while pressure rinsing. Continue pressure rinsing for 2 minutes or until rinsate becomes clear.
Replace the lid and close bottom valve.
Top Discharge IBC, Drums, Kegs (e.g. Snyder 120 Next Gen, Bonar B120, Drums, Kegs)
Triple rinsing the container before final disposal is the responsibility of the person disposing of the
container. To triple rinse the container before final disposal, empty the remaining contents from this
20
container into application equipment or mix tank. Fill the container at least 10 percent full with water.
Agitate vigorously or recirculate water with the pump for 2 minutes. Rinse all interior surfaces. Pour or
pump rinsate into application equipment or rinsate collection system. Repeat this procedure two more
times.
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill
or by incineration.
Top Discharge IBC, Drums, Kegs (e.g. Snyder 120 Next Gen, Bonar B120, Drums, and Kegs)
Triple rinsing the container before final disposal is the responsibility of the person disposing of the
container. To triple rinse the container before final disposal, empty the remaining contents from this
container into application equipment or mix tank. Fill the container at least 10 percent full with water.
Agitate vigorously or recirculate water with the pump for 2 minutes. Rinse all interior surfaces. Pour or
pump rinsate into application equipment or rinsate collection system. Repeat this procedure two more
times.
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill
or by incineration.
Non-Refillable Fiber Drums with Liners
Non-refillable container. DO NOT reuse or refill this container. Completely empty liner by shaking
and tapping sides and bottom to loosen clinging particles. Empty residue into application equipment,
then offer for recycling if available or dispose of in a sanitary landfill or by incineration. If drum is
contaminated and cannot be reused, dispose of it in the manner required for its liner.
Non-Rigid, Non-refillable Containers
Nonrefillable container. DO NOT reuse or refill this container. Completely empty container into
application equipment. Then offer for recycling if available or dispose of in a sanitary landfill or by
other procedures approved by state and local authorities.
[Refillable Containers]
Refillable container. Refer to Bottom Discharge IBC or Top Discharge IBC, Drums, Kegs information
as follows. Refill this container with pesticide only. DO NOT reuse this container for any other
purpose. Contact your Ag retailer or Bayer CropScience for container return, disposal and recycling
information.
Bottom Discharge IBC (e.g. Schuetz Caged IBC or Snyder Square Stackable)
Pressure rinsing the container before final disposal is the responsibility of the person disposing of the
container. Cleaning before refilling is the responsibility of the refiller. To pressure rinse the container
before final disposal, empty the remaining contents from the IBC into application equipment or mix
tank. Raise the bottom of the IBC by 1.5 inches on the side which is opposite of the bottom discharge
valve to promote more complete product removal. Completely remove the top lid of the IBC. Use
water pressurized to at least 40 PSI to rinse all interior portions. Continuously pump or drain rinsate
into application equipment or rinsate collection system while pressure rinsing. Continue pressure
rinsing for 2 minutes or until rinsate becomes clear. Replace the lid and close bottom valve.
21
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill
or by incineration.
Top Discharge IBC, Drums, Kegs (e.g. Snyder 120 Next Gen, Bonar B120, Drums, Kegs)
Triple rinsing the container before final disposal is the responsibility of the person disposing of the
container. Cleaning before refilling is the responsibility of the refiller. To triple rinse the containers
before final disposal, empty the remaining contents from this container into application equipment or
mix tank. Fill the container at least 10 percent full with water. Agitate vigorously or recirculate water
with the pump for 2 minutes. Rinse all interior surfaces. Pour or pump rinsate into application
equipment or rinsate collection system. Repeat this procedure two more times.
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill
or by incineration.
End users are authorized to remove tamper-evident cables as required to remove the product from
the container unless the container is equipped with one-way valves and refilling or returning is
planned. If this is the case, end-users are not authorized to remove tamper-evident cables, remove
one-way valves, or clean container.
22
IMPORTANT: READ BEFORE USE
Read the entire Directions for Use, Conditions, Disclaimer of Warrant ies and Limitations of Liability
before using this product. If terms are not acceptable, return the unopened product container at once.
By using this product, user or buyer accepts the following Conditi ons, Disclaimer of Warranties and
Limitations of Liability.
CONDITIONS: The directions for use of this product are believed to be adequate and must be
followed carefully. However, it is impossible to eliminate all risks associated with the use of this
product. Crop injury, ineffectiveness or other uninte nded consequences may result because of such
factors as weather conditions, presenc e of other materials, or the manner of use or appl ication, all of
which are beyond the control of Bayer CropScience. TO THE EXTENT CONSISTENT WITH
APPLICABLE LAW, all such risks shall be assumed by the user or buyer.
DISCLAIMER OF WARRANTIES: TO THE EXTENT CONSISTENT WITH APPLICABLE LAW ,
BAYER CROPSCIENCE MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, OF
MERCHANTABILITY OR OF FITNESS FOR A PA RTICULAR PURPOSE OR OTHERWISE, THAT
EXTEND BEYOND THE STATEMENTS MADE ON THIS LABEL. No agent of Bayer CropScience is
authorized to make any warranties beyond those co ntained herein or to modify the warranties
contained herein. TO THE EXTENT CONSISTENT WITH APPLICABLE LAW , BAYER
CROPSCIENCE DISCLAIMS ANY LIABILITY WHATSOEVER FOR SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT.
LIMITATIONS OF LIABILITY: TO THE EXTENT CONSISTENT WITH APPLICABLE LAW , THE
EXCLUSIVE REMEDY OF THE USER OR BUYER FOR ANY AND ALL LOSSES, INJURIES OR
DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT, WHETHER IN
CONTRACT, WARRANTY, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE, SHALL NOT EXCEED
THE PURCHASE PRICE PAID, OR AT BAYER CROPSCIENCESELECTION, THE REPLACEMENT OF
PRODUCT.
NET CONTENTS: 2.64 US Gallons (10 liters)
PREVICUR is a registered trademark of Bayer.
Produced for
Bayer CropScience LP
800 N. Lindbergh Blvd.
St. Louis, MO 63167
1-866-99BAYER (1-866-992-2937)
PREVICUR FLEX FUNGICIDE (PENDING) 02/22/2023, 02/23/2024, 07/26/2024