a97107de46
Image rebuild (skip scrape) / build (push) Failing after 1h37m12s
Dockerfile: self-contained image with corpus + Chroma + BM25 baked in. Drawbar's compose pulls + runs without volume mounts. Built from sources.json (labels schema), PRODUCT_NAME=crop_chem by default, HYBRID_SEARCH=true (always-on for production quality). RERANK_URL + OLLAMA_URL get set at compose time. .gitea/workflows/refresh.yml: monthly cron (1st @ 06:00 UTC) does full scrape → reindex → image push. Scrapes Bayer (~30 min) + EPA PPLS row-crop filtered (~7h). Skips reindex+push if no corpus diff. Tags pushed: :latest, :<sha12>, :corpus-<YYYY.MM.DD>. .gitea/workflows/image-only.yml: on-demand or auto on code-only pushes to main (paths: docs_mcp/, rag/, scrape/, requirements.txt, Dockerfile, sources.json). Reindexes from committed corpus, builds image, pushes. ~10 min vs ~9h full refresh. .gitignore: corpus/ now COMMITTED (4,159 labels, 265 MB of .md + sidecars). Lets image-only.yml rebuild indexes without re-scraping. chroma/ + bm25/ still gitignored (regenerable binary indexes). .dockerignore: drops venv, eval results, PLAN/README/CLAUDE.md, deploy/, .git/ — keeps the image lean. corpus + chroma + bm25 explicitly NOT in dockerignore (those go INTO the image). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
1062 lines
57 KiB
Markdown
1062 lines
57 KiB
Markdown
# SOYACYST TECH+
|
|
|
|
- EPA Reg No: **100-1517**
|
|
- Registrant: SYNGENTA CROP PROTECTION, LLC
|
|
- Signal word: Caution
|
|
- Active ingredients: Pasteuria nishizawae Pn1 (99.88%)
|
|
- Label accepted: 2013-07-18
|
|
- Source PDF: https://www3.epa.gov/pesticides/chem_search/ppls/085004-00007-20130718.pdf
|
|
|
|
---
|
|
STATES ENVIRONMENTAL PROTECT AGENCY
|
|
Ms. Susan Macintosh ;
|
|
Authorized Agent for Pasteuria Bioscience, Inc. (FBI)
|
|
Macintosh & Associates, Inc.
|
|
1203 Hartford Avenue
|
|
Saint Paul, MN 55.116-1622
|
|
Re: Your applications originally dated April 20, 2013 to update and/or add primary brand names,
|
|
alternate brand names, EPA Registration Numbers, EPA Establishment Numbers, and package
|
|
sizes consistent with Pesticide Registration (PR) Notice 98-10
|
|
spf*'*- ^BK^to^Kro^Sft^^l["Jj^ij ,a t"=9tr * jj^jj jtT jJ^"?,^ «"T?Tj- -)/'^?! ^Wt^i'J-j"it"i
|
|
SOYACYST™ TECH
|
|
SOYACYST™ TECH+
|
|
SOYACYST™ LF
|
|
SOYACYST™ WP PLUS
|
|
SOYACYST™ TECH PLUS
|
|
85004-6
|
|
85004-7
|
|
85004-9
|
|
85004-12
|
|
85004-13
|
|
-H^Si^iiiSfeL^^SiSsil?^
|
|
Update Primary Brand Name, Add
|
|
Alternate Brand Name & Add Package Size
|
|
Update Primary Brand Name, Add
|
|
Alternate Brand Name, Update EPA
|
|
Registration Number & Add EPA
|
|
Establishment Number
|
|
Update Primary and Alternate Brand
|
|
Names, Add Alternate Brand Name, Add
|
|
Package Size, & Update EPA Establishment
|
|
Numbers
|
|
Update Primary Brand Name, Add
|
|
Alternate Brand Name, Add Package Size,
|
|
and Update EPA Registration Number
|
|
Update Primary Brand Name, Add
|
|
Alternate Brand Name, Add Package Size,
|
|
and Update EPA Registration Number
|
|
478154
|
|
478155
|
|
478157
|
|
479653
|
|
479641
|
|
Dear Ms. Macintosh:
|
|
The Biopesticides and Pollution Prevention Division is in receipt of your applications, as indicated
|
|
above, for notification under PR Notice 98-10. The EPA conducted a preliminary screen of these
|
|
requests for their applicability under PR Notice 98-10 and determined that the actions requested fall
|
|
within the scope of this particular document. Our records have been duly noted, and the labels submitted
|
|
with these applications have been stamped "Notification Accepted" and will be placed in our records.
|
|
Submit two (2) copies of final printed labeling (for each product) before the products, as modified, are
|
|
sold or distributed [40 C.F.R. § 156.10(W6YI.
|
|
CONCURRENCES
|
|
iYMBOL ^>
|
|
;URNAME ^>
|
|
IATE ^»
|
|
7SU P
|
|
K-ftus^H
|
|
«7/l7/2ol3
|
|
...35A\?.
|
|
Qi<yu£J>
|
|
1\VW7
|
|
"fell??
|
|
•Status.SPA Form 1320-1A (1/90) Printed on Recycled Paper OFFICIAL FILE COPY
|
|
•in) Pt-int^nrr Affl,-.ii.
|
|
|
|
Susan Macintosh
|
|
EPA Registration No. 85004-6, -7, -9, -12, and -13
|
|
Should you wish to retain the reference to FBI's website on your labels, then please be aware that the
|
|
website becomes labeling under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) and is
|
|
subject to review by the EPA. If the website is false or misleading, the products would be misbranded
|
|
and unlawful to sell or distribute under FIFRA section 12(a)(l)(E). 40 C.F.R. § 156.10(a)(5) lists
|
|
examples of statements the EPA may consider false or misleading. In addition, regardless of whether a
|
|
website is referenced on the labels of your products, claims made on the website may not substantially
|
|
differ from those claims approved through the registration/amendment process. Therefore, should the
|
|
EPA find or if it is brought to our attention'that a website contains false or misleading statements or
|
|
claims substantially differing from the EPA-approved registration/amendment, the website will be
|
|
referred to the EPA's Office of Enforcement and Compliance Assurance.
|
|
If you have any questions regarding this letter, please contact Ms. Jeannine Kausch by telephone (703-
|
|
347-8920) or email (kausch.jeannine@epa.gov).
|
|
Sincerely,
|
|
Kimberly NescVchief
|
|
Microbial Pesticides Branch
|
|
Biopesticides and Pollution
|
|
Prevention Division (75IIP)
|
|
|
|
rPlease read instructions on reverse b'y J completing form. rForm Approved. V. ,.3 No. 2070-0060. Approval expires 2-28-95
|
|
SEPA
|
|
United States
|
|
Environmental Protection Agency
|
|
Washington, DC 20460
|
|
D Registration
|
|
D Amendment
|
|
HI Other
|
|
OPP Identifier Number
|
|
Application for Pesticide - Section I
|
|
1. Company/Product Number
|
|
85004-9
|
|
4. Company/Product (Name)
|
|
Soyacyst LF / Soyacyst ST
|
|
2. EPA Product Manager
|
|
Kimberly Nesci
|
|
PM#
|
|
92
|
|
3. Proposed Classification
|
|
W None I I Restricted
|
|
5. Name and Address of Application (Include ZIP Code)
|
|
Pasteuria Bioscience, Inc.
|
|
12085 Research Dr
|
|
Alachua, FL 32615
|
|
I I Check if this is a new address
|
|
6. Expedited Review. In accordance with FIFRA Section 3(c)(3)
|
|
(b)(i), my product is similar or identical in composition and labeling
|
|
to:
|
|
EPA Reg. No.
|
|
Product Name
|
|
Section II
|
|
I I Amendment - Explain below.
|
|
I I Resubmission in response to Agency letter dated
|
|
H Notification - Explain below.
|
|
Final printed labels in response to
|
|
Agency letter dated
|
|
I I "Me Too" Application.
|
|
I I Other - Explain below.
|
|
Explanation: Use additional page(s) if necessary. (For section I and Section II.)
|
|
Notification of new brand names, per PR Notice 98-10. This notification is consistent with the provisions of PR Notice 98-10 and
|
|
EPA regulations at 40 CFR 152.46, and no other changes have been made to the labeling or the confidential statement of
|
|
formula of this product. I understand that it is a violation of 18 U.S.C. Sec. 1001 to willfully make any false statement to EPA. I
|
|
further understand that if this notification is not consistent with the terms of PR Notice 98-10 and 40 CFR 152.46, this product
|
|
may be in violation of FIFRA and I may be subject to enforcement action and penalties under sections 12 and 14 of FIFRA.
|
|
Section III
|
|
Child-Resistant Packaging
|
|
D Yes
|
|
* Certification must
|
|
be submitted
|
|
Unit Packaging
|
|
1*1 NO
|
|
If "Yes" No. per
|
|
Unit Packaging wgt. Container
|
|
Water Soluble Packaging
|
|
D Yes
|
|
If "Yes-
|
|
Package wgt
|
|
No. per
|
|
container
|
|
2. Type of Container
|
|
13 Metal
|
|
HI Plastic
|
|
I I Glass
|
|
II Paper c c c c
|
|
c
|
|
c c c c
|
|
3. Location of Net Contents Information
|
|
I3 Label Dcontainer
|
|
4. Size(s) Retail Container
|
|
2.5, 5,10 or 15 gallons
|
|
6. Manner in Which Label is Affixed to
|
|
Product
|
|
I I Lithograph
|
|
E£I Paper glued
|
|
l~~l Stenciled
|
|
l~~l Other.
|
|
5. Location dr Label Direction c
|
|
HI On Label { . c c
|
|
I I On Labeling accompanying 'product
|
|
Section IV
|
|
1. Contact Point (Complete items directly below for identification of individual to be contacted, if necessary, to process this application.)
|
|
Name
|
|
Susan Macintosh
|
|
Title
|
|
Regulatory Consultant for PBI
|
|
Telephone No. (Include Area Code)
|
|
651-340-1262
|
|
Certification
|
|
I certify that the statements I have made on this form and all attachments thereto are true, accurate and complete.
|
|
I acknowledge any knowingly false or misleading statement may be punishable by fine or imprisonment or
|
|
both under applicable law.
|
|
2. Signature
|
|
4. Typed Name
|
|
Susan Macintosh
|
|
3. Title
|
|
Regulatory Consultant for PBI
|
|
5. Date
|
|
17 April 2013
|
|
6. Date Application
|
|
Received
|
|
(Stamped)
|
|
|
|
SOYAC YST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH the ALTERNATE BRAND NAME:
|
|
Clariva™pnLF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME;
|
|
SOYACYST™ST
|
|
Biological control for use on soybean seed against soybean cyst nematode
|
|
MASTER LABEL
|
|
SUB-LABEL A: FOR AGRICULTURAL USE As FOLIAR TREATMENT AND SEED
|
|
TREATMENT
|
|
SUB-LABEL B: FOR AGRICULTURAL USE As FOLIAR TREATMENT
|
|
SUB-LABEL C: FOR SEED TREATMENT
|
|
^ FOR ORGANIC PRODUCTION
|
|
Active Ingredient: Pasteuria nishizawae — Pnl* 33.29%
|
|
Other Ingredients: 66.71%
|
|
Total: '. 100.00%
|
|
*Contains at least 2xl08 spores per g or 9.1xl010 spores per pound.
|
|
EPA Registration N°: 85004-9
|
|
EPA Est. Number: 100-NC-002 or 70051-CA-001 or 88913-CHK-001
|
|
Notification AcceptedManufactured for:
|
|
Date: 07 / 13
|
|
Reviewer: -r
|
|
PASTEURIAbioscience12085 Research Dr. (386)462-0008
|
|
Alachua, FL 32615 www.pasteuriabio.com
|
|
™ SOYACYST™ is a trademark of Pasteuria Bioscience, Inc.
|
|
Clariva™, the ALLIANCE FRAME, the SYNGENTA Logo, and the PURPOSE ICON are
|
|
Trademarks of a Syngenta Group Company
|
|
|
|
r (Proposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
SOYACYST™LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME:
|
|
CLARIVA™ pn LFBiological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME:
|
|
SOYACYST ™ST
|
|
Biological control for use on soybean seed against soybean cyst nematode
|
|
SUB-LABEL A
|
|
FOR AGRICULTURAL USE AS FOLIAR APPLICATION
|
|
AND SEED TREATMENT
|
|
Pasteuria Bioscience, Inc. 2 of 28 15 July 2013
|
|
|
|
r fProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
SUB-LABEL A
|
|
SOYACYST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH the ALTERNATE BRAND NAME:
|
|
Clariva™ pn LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME;
|
|
SOYACYST™ ST
|
|
Biological control for use on soybean seed against soybean cyst nematode
|
|
^ FOR ORGANIC PRODUCTION
|
|
Active Ingredient: Pasteuria nishizawae — Pnl* 33.29%
|
|
Other Ingredients: 66.71%
|
|
Total: 100.00%
|
|
* Contains at least 2x10 spores per g or 9.1x10 spores per pound.
|
|
KEEP OUT OF REACH OF CHILDREN
|
|
CAUTION
|
|
See additional precautionary and first aid statements on the back panel
|
|
Net Contents: 2.5, 5, 10 or 15 gallons
|
|
EPA Registration N°: 85004-9
|
|
EPA Est. Number: 100-NC-002 or 70051-CA-001 or 88913-CHK-001
|
|
Manufactured for:
|
|
* PASTEURIAbioscience12085 Research Dr. (386) 462-0008
|
|
Alachua, FL 32615 www.pasteuriabio.com
|
|
™ SOYACYST is a trademark of Pasteuria Bioscience, Inc.
|
|
Clariva™ , the ALLIANCE FRAME, the SYNGENTA Logo, and the PURPOSE ICON are
|
|
Trademarks of a Syngenta Group Company
|
|
Pasteuria Bioscience, Inc. 3 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
PRECAUTIONARY STATEMENTS
|
|
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
|
|
CAUTION
|
|
Harmful if inhaled. Avoid breathing spray mist. Remove and wash contaminated clothing
|
|
before reuse.
|
|
FIRST AID
|
|
If inhaled:
|
|
Move person to fresh air.
|
|
If person is not breathing, call 911 or an ambulance, then give artificial
|
|
respiration, preferably mouth-to-mouth if possible.
|
|
Call a poison control center or doctor for treatment advice.
|
|
HOT LINE NUMBER
|
|
Have the product container or label with you when calling a poison control center or doctor,
|
|
or going for treatment. For emergency information concerning this product, call the National
|
|
Pesticide Information Center (NPIC) at 1-800-858-7378 seven days a week, 6:30 am to 4:30
|
|
pm Pacific Time. During other times, call your poison control center at 1-800-222-1222.
|
|
PERSONAL PROTECTIVE EQUIPMENT (PPE)
|
|
Applicators and other handlers must wear:
|
|
• Long-sleeved shirt and long pants
|
|
• Shoes plus socks
|
|
Mixers/loaders and applicators must wear a dust/mist filtering respirator meeting NIOSH
|
|
standards of at least N-95, R-95, or P-95. Repeated exposure to high concentrations of
|
|
microbial proteins can cause allergic sensitization.
|
|
Follow the manufacturer's instructions for cleaning/maintaining PPE. If no such instructions
|
|
are available, use detergent and hot water for washables. Keep and wash PPE separately from
|
|
other laundry.
|
|
Pasteuria Bioscience, Inc. 4 of 28 15 July 2013
|
|
|
|
rProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
USER SAFETY RECOMMENDATIONS
|
|
Users should:
|
|
• Wash hands before eating, drinking, chewing gum, using tobacco or using the toilet.
|
|
• Remove clothing/PPE immediately if pesticide gets inside. Then wash thoroughly and
|
|
put on clean clothing.
|
|
• Remove PPE immediately after handling this product. As soon as possible, wash
|
|
thoroughly and change into clean clothing.
|
|
ENVIRONMENTAL HAZARDS
|
|
[Containers with capacities of 5 gallons or less:] For terrestrial uses, do not apply directly to
|
|
water, or to areas where surface water is present or to intertidal areas below the mean high
|
|
water mark.
|
|
Do not contaminate water when disposing of equipment wash waters or rinsate.
|
|
[Containers with capacities greater than 5 gallons:] Do not discharge effluent containing this
|
|
product into lakes, streams, ponds, estuaries, oceans, or other waters unless in accordance
|
|
with the requirements of a National Pollutant Discharge Elimination System (NPDES) permit
|
|
and the permitting authority has been notified in writing prior to discharge. Do not discharge
|
|
effluent containing this product to sewer systems without previously notifying the local
|
|
sewage treatment plant authority. For guidance, contact your State Water Board or Regional
|
|
Office of EPA.
|
|
For terrestrial uses, do not apply directly to water, or to areas where surface water is present
|
|
or to intertidal areas below the mean high water mark.
|
|
Do not contaminate water when disposing of equipment wash waters or rinsate.
|
|
DIRECTIONS FOR USE
|
|
It is a violation of Federal law to use this product in a manner inconsistent with its
|
|
labeling.
|
|
Do not use this product until you have read the entire label. Do not apply this product in a
|
|
way that will contact workers or other persons, either directly or through drift. Only protected
|
|
handlers may be in the area during application. For any requirement specific to your State or
|
|
Tribe, consult the State or Tribal agency responsible for pesticide regulation.
|
|
Pasteuria Bioscience, Inc. 5 of 28 15 July 2013
|
|
|
|
cProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
AGRICULTURAL USE REQUIREMENTS
|
|
Use this product only in accordance with its labeling and with the Worker Protection
|
|
Standard, 40 CFR Part 170. This Standard contains requirements for the protection of
|
|
agricultural workers on farms, forests, nurseries, and greenhouses, and handlers of agricultural
|
|
pesticides. It contains requirements for training, decontamination, notification and emergency
|
|
assistance. It also contains specific instructions and exceptions pertaining to the statements
|
|
on this label about personal protective equipment (PPE) and restricted-entry interval. The
|
|
requirements in this box apply only to the uses of this product that are covered by the Worker
|
|
Protection Standard.
|
|
Do not enter or allow worker entry into treated areas during the restricted-entry interval (REI)
|
|
of 4 hours.
|
|
EXCEPTION: If the product is soil injected or soil incorporated, the Worker Protection
|
|
Standard, under certain circumstances, allows workers to enter the treated area if there will be
|
|
no contact with anything that has been treated.
|
|
PPE required for early entry to treated areas (that is permitted under the Worker Protection
|
|
Standard and that involves contact with anything that has been treated, such as plants, soil or
|
|
water) is:
|
|
• Water proof gloves
|
|
• Coveralls
|
|
• Shoes plus socks
|
|
NON- AGRICULTURAL USE REQUIREMENTS
|
|
The requirements in this box apply to uses of this product that are NOT within the scope
|
|
of the Worker Protection Standard for agricultural pesticides (40 CFR Part 170). The
|
|
WPS applies when this product is used to produce agricultural plants on farms, forests,
|
|
nurseries or greenhouses.
|
|
Keep unprotected persons out of treatment areas until seeds have dried or been packaged.
|
|
PRODUCT INFORMATION
|
|
This product contains a biological nematicide for the control of the following nematode:
|
|
Soybean Cyst Nematode Heterodera glycines
|
|
Pasteuria Bioscience, Inc. 6 of 28 15 July 2013
|
|
|
|
f to
|
|
Proposed Label for SOY AC YST™ LF / ST
|
|
Sub-Label A
|
|
FOR USE As FOLIAR APPLICATION
|
|
APPLICATION INSTRUCTIONS
|
|
Soybean: Apply 1.3 to 64 fluid ounces (fl oz) of SOYACYST™ LF per 1000 square feet of
|
|
soybean prior to planting and subsequently in 3 to 4 week intervals. Use the higher
|
|
application rate on sites with high Soybean cyst nematode populations (greater than 50
|
|
Soybean cyst nematodes per 0.4 cup [100cm3] of soil) or areas with extensive nematode
|
|
damage such as stunted plants, dying plants, or heavily stunted root systems compared to
|
|
unaffected plants in the same field. For best control, a minimum of 3 sequential applications is
|
|
required. Monthly applications throughout the year may help maintain Soybean cyst
|
|
nematode populations below economic threshold levels.
|
|
SOYACYST™ LF may be diluted in water to attain proper distribution across the area to be
|
|
treated. This product may be applied using standard calibrated ground spray-application
|
|
equipment and incorporated to a 4-inch depth prior to bed formation or applied via
|
|
chemigation through the irrigation system after bed formation (pre-planting). Agitation in the
|
|
mix tank is recommended for any application requiring dilution of the formulated product
|
|
with water prior to application. When mixing, fill the tank one-half full with water, add
|
|
SOYACYST™ LF slowly to the tank with hydraulic or mechanical agitation, and continue to
|
|
fill with water. For diluted product applications, apply product in the appropriate amount of
|
|
water to treat the root-zone of the crop without flushing the product beyond the root-zone of
|
|
the crop (this can vary with soil type and crop stage).
|
|
Apply enough water following all applications to move the Pasteuria spores into the soybean
|
|
root-zone and to flush the irrigation lines of any remaining product. After application of
|
|
SOYACYST™ LF and subsequent treatment with water, minimizing irrigation for several
|
|
weeks following treatment may improve Soybean cyst nematode control. For areas under
|
|
intense irrigation, repeat applications may be necessary to maintain Soybean cyst nematode
|
|
populations below an economic threshold.
|
|
DAYS TO HARVEST
|
|
There are no restrictions on applying SOYACYST™ LF up to the time of harvest.
|
|
Pasteuria Bioscience, Inc. 7 of 28 15 July 2013
|
|
|
|
fProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
CHEMIGATION
|
|
Basic Requirements:
|
|
1) Apply this product only through sprinkler (including center pivot, lateral move, end
|
|
tow, side (wheel) roll, traveler, big gun, solid set, or hand move) and drip (trickle)
|
|
irrigation systems. Do not apply this product through any other type of irrigation
|
|
system.
|
|
2) Crop injury or lack of effectiveness can result from non-uniform distribution of treated
|
|
water.
|
|
3) If you have questions about calibration, you should contact State Extension Service
|
|
specialists, equipment manufacturers, or other experts.
|
|
4) Do not connect an irrigation system (including greenhouse systems) used for pesticide
|
|
application to a public water system unless the pesticide label-prescribed safety
|
|
devices for public water systems are in place.
|
|
5) A person knowledgeable of the chemigation system and responsible for its operation,
|
|
or under the supervision of the responsible person, shall shut the system down and
|
|
make any necessary adjustments should the need arise.
|
|
Requirements for Chemigation Systems Connected to Public Water Systems:
|
|
1) Public water supply means a system for the provision to the public of piped water for
|
|
human consumption if such system has at least 15 service connections or regularly
|
|
serves an average of 25 individuals daily at least 60 days throughout the year.
|
|
2) Chemigation systems connected to the public water systems must contain a functional,
|
|
reduced-pressure zone (RPZ), backflow preventer or the functional equivalent in the
|
|
water supply upstream from the point of pesticide introduction. As an option to the
|
|
RPZ, the water from the public water system should be discharged into a reservoir
|
|
tank prior to pesticide introduction. There shall be a complete physical break (air gap)
|
|
between the flow outlet end of the fill pipe and the top or overflow rim of the reservoir
|
|
tank of at least twice the inside diameter of the fill pipe.
|
|
3) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
4) The pesticide injection pipeline must contain a functional, normally closed, solenoid-
|
|
operated valve located on the intake side of the injection pump and connected to the
|
|
system interlock to prevent fluid from being withdrawn from the supply tank when the
|
|
irrigation system is either automatically or manually shut down.
|
|
5) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops, or in cases where there is
|
|
no water pump, when the water pressure decreases to the point where pesticide
|
|
distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection pump
|
|
(e.g., diaphragm pump), effectively designed and constructed of materials that are
|
|
compatible with pesticides and capable of being fitted with a system interlock.
|
|
7) Do not apply when wind speed favors drift beyond the area intended for treatment.
|
|
Pasteuria Bioscience, Inc. 8 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
Requirements for Sprinkler Chemigation:
|
|
1) The system must contain a functional check valve, vacuum relief valve, and low
|
|
pressure drain appropriately located on the irrigation pipeline to prevent water source
|
|
contamination from back flow.
|
|
2) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
3) The pesticide injection pipeline must also contain a functional, normally closed,
|
|
solenoid-operated valve located on the intake side of the injection pump and
|
|
connected to the system interlock to prevent fluid from being withdrawn from the
|
|
supply tank when the irrigation system is either automatically or manually shut down.
|
|
4) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops.
|
|
5) The irrigation line or water pump must include a functional pressure switch, which
|
|
will stop the water pump motor when the water pressure decreases to the point where
|
|
pesticide distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection pump
|
|
(e.g., diaphragm pump), effectively designed and constructed of materials that are
|
|
compatible with pesticides and capable of being fitted with a system interlock.
|
|
7) Do not apply when wind speed favors drift beyond the area intended for treatment.
|
|
Requirements for Drip Chemigation:
|
|
1) The system must contain a functional check valve, vacuum relief valve and
|
|
low pressure drain appropriately located on the irrigation pipeline to prevent water
|
|
source contamination from back flow.
|
|
2) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
3) The pesticide injection pipeline must also contain a functional, normally closed,
|
|
solenoid-operated valve located on the intake side of the injection pump and
|
|
connected to the system interlock to prevent fluid from being withdrawn from the
|
|
supply tank when the irrigation system is either automatically or manually shut down.
|
|
4) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops.
|
|
5) The irrigation line or water pump must include a functional pressure switch, which will
|
|
stop the water pump motor when the water pressure decreases to the point where
|
|
pesticide distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection
|
|
pump (e.g., diaphragm pump), effectively designed and constructed of
|
|
materials that are compatible with pesticides and capable of being fitted with
|
|
a system interlock.
|
|
Pasteuria Bioscience, Inc. 9 of 28 15 July 2013
|
|
|
|
rProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
FOR USE AS A SEED TREATMENT
|
|
Treatment of highly mechanically scarred or damaged seed, or seed known to be of low vigor
|
|
and poor quality, except for the purpose of curative control of existing disease pests, may
|
|
result in reduced germination and/or reduction of seed and seedling vigor. Treat a small
|
|
quantity of seed using equipment similar to that planned for treating the total seed lot.
|
|
Conduct germination tests on a small portion of seed before committing the total seed lot to a
|
|
selected seed treatment. Due to seed quality, crop or variety sensitivity, and seed storage
|
|
conditions beyond the control of manufacturer, no claims are made to guarantee the
|
|
germination of carry-over seed or propagating material for all crop seed.
|
|
FOR USE AS A PRE-PLANT SEED TREATMENT
|
|
Treat only those seeds needed for immediate use, minimizing the interval between treatment
|
|
and planting. Do not store excess treated seeds beyond planting time.
|
|
To achieve improved application coverage to the seed, dilute SOYACYST™ LF with water
|
|
and apply directly to dry seed or mix with inoculants and/or other registered seed treatment
|
|
coatings (e.g., colorants, polymers, etc.), insecticides and fungicides. Do not mix
|
|
SOYACYST™ LF with any product containing a label prohibition against such mixing.
|
|
When tank-mixing with any other registered seed treatment insecticide and/or fungicide,
|
|
always read and follow all use directions, restrictions, and precautions of both SOYACYST™
|
|
LF and the tank mix partner(s). The resulting tank mix must be in accordance with the more
|
|
restrictive label limitations and precautions. Do not exceed label dosage rates. Please consult
|
|
Pasteuria Bioscience, Inc. for additional information (http://www.pasteuriabio.com/).
|
|
SOYBEAN
|
|
For control of soybean cyst nematode, apply 2 to 12 fluid ounces of SOYACYST™ LF per
|
|
100 Lbs (60-150 mL per 45.4 kg) of soybean seed.
|
|
FOR USE AS A COMMERICAL SEED TREATMENT
|
|
To achieve improved application coverage to the seed, dilute SOYACYST™ LF with water
|
|
and apply directly to dry seed or mix with inoculants and/or other registered seed treatment
|
|
coating (e.g., colorants, polymers, etc.), insecticides and fungicides. Do not mix
|
|
SOYACYST™ LF with any product containing a label prohibition against such mixing.
|
|
When tank-mixing with any other registered seed treatment insecticide and/or fungicide,
|
|
always read and follow all use directions, restrictions, and precautions of both SOYACYST™
|
|
LF and the tank mix partner(s). The resulting tank mix must be in accordance with the more
|
|
restrictive label limitations and precautions. Do not exceed label dosage rates. Please consult
|
|
Pasteuria Bioscience, Inc. for additional information (http://www.pasteuriabio. com/).
|
|
SOYBEAN
|
|
For control of soybean cyst nematode, apply 2 to 12 fluid ounces of SOYACYST™ LF per
|
|
100 Lbs (60-150 mL per 45.4 kg) of soybean seed.
|
|
Pasteuria Bioscience, Inc. 10 of 28 15 July 2013
|
|
|
|
r rProposed Label for SOYACYST™ LF / ST
|
|
Sub-Label A
|
|
STORAGE AND DISPOSAL
|
|
Do not contaminate water, food, or feed by storage and disposal.
|
|
PESTICIDE STORAGE
|
|
Store refrigerated (~4°C). Reclose container of unused portions of SOYACYST™ LF.
|
|
PESTICIDE DISPOSAL
|
|
To avoid wastes, use all material in this container by application according to label directions.
|
|
If wastes cannot be avoided, offer remaining product to a waste disposal facility or pesticide
|
|
disposal program (often such programs are run by state or local governments or by industry).
|
|
CONTAINER HANDLING
|
|
[Plastic containers with capacities equal to or less than 5 gallons:] Nonrefillable container. Do
|
|
not reuse or refill this container. Triple rinse container (or equivalent) promptly after
|
|
emptying. Triple rinse as follows: Empty the remaining contents into application equipment
|
|
or a mix tank and drain for 10 seconds after the flow begins to drip. Fill the container 1/4 full
|
|
with water and recap. Shake for 10 seconds. Pour rinsate into application equipment or a mix
|
|
tank, or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to
|
|
drip. Repeat this procedure two more times. Then offer for recycling if available or puncture
|
|
and dispose of in a sanitary landfill, or by incineration. Do not burn, unless allowed by state
|
|
and local ordinance. If burned, stay out of smoke.
|
|
[Plastic containers with capacities greater than 5 gallons:] Nonrefillable container. Do not
|
|
reuse or refill this container. Triple rinse container (or equivalent) promptly after emptying.
|
|
Triple rinse as follows: Empty the remaining contents into application equipment or a mix
|
|
tank. Fill the container 1/4 full with water. Replace and tighten closures. Tip container on its
|
|
side and roll it back and forth, ensuring at least one complete revolution, for 30 seconds.
|
|
Stand the container on its end and tip it back and forth several times. Turn the container over
|
|
onto its other end and tip it back and forth several times. Empty the rinsate into application
|
|
equipment or a mix tank, or store rinsate for later use or disposal. Repeat this procedure two
|
|
more times. Then offer for recycling if available or puncture and dispose of in a sanitary
|
|
landfill, or by incineration. Do not burn, unless allowed by state and local ordinance. If
|
|
burned, stay out of smoke.
|
|
WARRANTY STATEMENT
|
|
Pasteuria Bioscience, Inc. (FBI) warrants that this product conforms to its label description
|
|
and is suitable for its intended use if stored and used in accordance with the Directions for
|
|
Use. To the extent consistent with applicable law, FBI makes no warranty, express or implied,
|
|
of merchantability, fitness or otherwise concerning the use of this product other than as
|
|
indicated on this label. To the extent consistent with applicable law, user assumes all risks of
|
|
use, storage or handling not in accordance with accompanying directions.
|
|
Pasteuria Bioscience, Inc. 11 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
SOYACYST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH the ALTERNATE BRAND NAME;
|
|
Clariva™ pn LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
SUB-LABEL B
|
|
FOR AGRICULTURAL USE AS FOLIAR APPLICATION
|
|
Pasteuria Bioscience, Inc. 12 of 28 15 July 2013
|
|
|
|
( rProposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
SUB-LABEL B
|
|
SOYACYST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH the ALTERNATE BRAND NAME:
|
|
Clariva™pnLF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
%> FOR ORGANIC PRODUCTION
|
|
Active Ingredient: Pasteuria nishizawae-Pnl* ..33.29%
|
|
Other Ingredients: 66.71%
|
|
Total: 100.00%
|
|
* Contains at least 2xl08 spores per g or 9.1xld10 spores per pound.
|
|
KEEP OUT OF REACH OF CHILDREN
|
|
CAUTION
|
|
See additional precautionary and first aid statements on the back panel
|
|
Net Contents: 2.5, 5, 10 or 15 gallons
|
|
EPA Registration N°: 85004-9
|
|
EPA Est. Number: 100-NC-002 or 70051-CA-001 or 88913-CHK-001
|
|
Manufactured for:
|
|
®PASTEURIAbioscience12085 Research Dr., Suite 185
|
|
Alachua,FL32615
|
|
(386) 462-0008
|
|
www.pasteuriabio. com/
|
|
™ SOYACYST is a trademark of Pasteuria Bioscience, Inc.
|
|
Clariva™ , the ALLIANCE FRAME, the SYNGENTA Logo, and the PURPOSE ICON are
|
|
Trademarks of a Syngenta Group Company
|
|
Pasteuria Bioscience, Inc. 13 of 28 15 July 2013
|
|
|
|
fProposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
PRECAUTIONARY STATEMENTS
|
|
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
|
|
CAUTION
|
|
Harmful if inhaled. Avoid breathing spray mist. Remove and wash contaminated clothing
|
|
before reuse.
|
|
FIRST AID
|
|
If inhaled:
|
|
Move person to fresh air.
|
|
If person is not breathing, call 911 or an ambulance, then give artificial
|
|
respiration, preferably mouth-to-mouth if possible.
|
|
Call a poison control center or doctor for treatment advice.
|
|
HOT LINE NUMBER
|
|
Have the product container or label with you when calling a poison control center or doctor,
|
|
or going for treatment. For emergency information concerning this product, call the National
|
|
Pesticide Information Center (NPIC) at 1-800-858-7378 seven days a week, 6:30 am to 4:30
|
|
pm Pacific Time. During other times, call your poison control center at 1-800-222-1222.
|
|
PERSONAL PROTECTIVE EQUIPMENT (PPE)
|
|
Applicators and other handlers must wear:
|
|
• Long-sleeved shirt and long pants
|
|
• Shoes plus socks
|
|
Mixers/loaders and applicators must wear a dust/mist filtering respirator meeting NIOSH
|
|
standards of at least N-95, R-95, or P-95. Repeated exposure to high concentrations of
|
|
microbial proteins can cause allergic sensitization.
|
|
Follow the manufacturer's instructions for cleaning/maintaining PPE. If no such instructions
|
|
are available, use detergent and hot water for washables. Keep and wash PPE separately from
|
|
other laundry.
|
|
USER SAFETY RECOMMENDATIONS
|
|
Users should:
|
|
• Wash hands before eating, drinking, chewing gum, using tobacco or using the toilet.
|
|
• Remove clothing/PPE immediately if pesticide gets inside. Then wash thoroughly and
|
|
put on clean clothing.
|
|
• Remove PPE immediately after handling this product. As soon as possible, wash
|
|
thoroughly and change into clean clothing.
|
|
Pasteuria Bioscience, Inc. 14 of 28 15 July 2013
|
|
|
|
r rProposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
ENVIRONMENTAL HAZARDS
|
|
Do not apply directly to water, or to areas where surface water is present or to intertidal areas
|
|
below the mean high water mark.
|
|
Do not contaminate water when disposing of equipment wash waters or rinsate.
|
|
DIRECTIONS FOR USE
|
|
It is a violation of Federal law to use this product in a manner inconsistent with its
|
|
labeling.
|
|
Do not use this product until you have read the entire label. Do not apply this product in a
|
|
way that will contact workers or other persons, either directly or through drift. Only protected
|
|
handlers may be in the area during application. For any requirement specific to your State or
|
|
Tribe, consult the State or Tribal agency responsible for pesticide regulation.
|
|
AGRICULTURAL USE REQUIREMENTS
|
|
Use this product only in accordance with its labeling and with the Worker Protection
|
|
Standard, 40 CFR Part 170. This Standard contains requirements for the protection of
|
|
agricultural workers on farms, forests, nurseries, and greenhouses, and handlers of agricultural
|
|
pesticides. It contains requirements for training, decontamination, notification and emergency
|
|
assistance. It also contains specific instructions and exceptions pertaining to the statements
|
|
on this label about personal protective equipment (PPE) and restricted-entry interval. The
|
|
requirements in this box apply only to the uses of this product that are covered by the Worker
|
|
Protection Standard.
|
|
Do not enter or allow worker entry into treated areas during the restricted-entry interval (REI)
|
|
of 4 hours.
|
|
EXCEPTION: If the product is soil injected or soil incorporated, the Worker Protection
|
|
Standard, under certain circumstances, allows workers to enter the treated area if there will be
|
|
no contact with anything that has been treated.
|
|
PPE required for early entry to treated areas (that is permitted under the Worker Protection
|
|
Standard and that involves contact with anything that has been treated, such as plants, soil or
|
|
water) is:
|
|
• Water proof gloves
|
|
• Coveralls
|
|
• Shoes plus socks
|
|
Pasteuria Bioscience, Inc. 15 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
PRODUCT INFORMATION
|
|
This product contains a biological nematicide for the control of the following nematode:
|
|
Soybean Cyst Nematode Heterodera glycines
|
|
APPLICATION INSTRUCTIONS
|
|
Soybean: Apply 1.3 to 64 fluid ounces (fl oz) of SOYACYST™ LF per 1000 square feet of
|
|
soybean prior to planting and subsequently in 3 to 4 week intervals. Use the higher
|
|
application rate on sites with high Soybean cyst nematode populations (greater than 50
|
|
Soybean cyst nematodes per 0.4 cup [100cm3] of soil) or areas with extensive nematode
|
|
damage such as stunted plants, dying plants, or heavily stunted root systems compared to
|
|
unaffected plants in the same field. For best control, a minimum of 3 sequential applications is
|
|
required. Monthly applications throughout the year may help maintain Soybean cyst
|
|
nematode populations below economic threshold levels.
|
|
SOYACYST™ LF may be diluted in water to attain proper distribution across the area to be
|
|
treated. This product may be applied using standard calibrated ground spray-application
|
|
equipment and incorporated to a 4-inch depth prior to bed formation or applied via
|
|
chemigation through the irrigation system after bed formation (pre-planting). Agitation in the
|
|
mix tank is recommended for any application requiring dilution of the formulated product
|
|
with water prior to application. When mixing, fill the tank one-half full with water, add
|
|
SOYACYST™ LF slowly to the tank with hydraulic or mechanical agitation, and continue to
|
|
fill with water. For diluted product applications, apply product in the appropriate amount of
|
|
water to treat the root-zone of the crop without flushing the product beyond the root-zone of
|
|
the crop (this can vary with soil type and crop stage).
|
|
Apply enough water following all applications to move the Pasteuria spores into the soybean
|
|
root-zone and to flush the irrigation lines .of any remaining product. After application of
|
|
SOYACYST™ LF and subsequent treatment with water, minimizing irrigation for several
|
|
weeks following treatment may improve Soybean cyst nematode control. For areas under
|
|
intense irrigation, repeat applications may be necessary to maintain Soybean cyst nematode
|
|
populations below an economic threshold.
|
|
DAYS TO HARVEST
|
|
There are no restrictions on applying SOYACYST™ LF up to the time of harvest.
|
|
Pasteuria Bioscience, Inc. 16 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
CHEMIGATION
|
|
Basic Requirements:
|
|
1) Apply this product only through sprinkler (including center pivot, lateral move, end
|
|
tow, side (wheel) roll, traveler, big gun, solid set, or hand move) and drip (trickle)
|
|
irrigation systems. Do not apply this product through any other type of irrigation
|
|
system.
|
|
2) Crop injury or lack of effectiveness can result from non-uniform distribution of treated
|
|
water.
|
|
3) If you have questions about calibration, you should contact State Extension Service
|
|
specialists, equipment manufacturers, or other experts.
|
|
4) Do not connect an irrigation system (including greenhouse systems) used for pesticide
|
|
application to a public water system unless the pesticide label-prescribed safety
|
|
devices for public water systems are in place.
|
|
5) A person knowledgeable of the chemigation system and responsible for its operation,
|
|
or under the supervision of the responsible person, shall shut the system down and
|
|
make any necessary adjustments should the need arise.
|
|
Requirements for Chemigation Systems Connected to Public Water Systems:
|
|
1) Public water supply means a system for the provision to the public of piped water for
|
|
human consumption if such system has at least 15 service connections or regularly
|
|
serves an average of 25 individuals daily at least 60 days throughout the year.
|
|
2) Chemigation systems connected to the public water systems must contain a functional,
|
|
reduced-pressure zone (RPZ), backflow preventer or the functional equivalent in the
|
|
water supply upstream from the point of pesticide introduction. As an option to the
|
|
RPZ, the water from the public water system should be discharged into a reservoir
|
|
tank prior to pesticide introduction. There shall be a complete physical break (air gap)
|
|
between the flow outlet end of the fill pipe and the top or overflow rim of the reservoir
|
|
tank of at least twice the inside diameter of the fill pipe.
|
|
3) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
4) The pesticide injection pipeline must contain a functional, normally closed, solenoid-
|
|
operated valve located on the intake side of the injection pump and connected to the
|
|
system interlock to prevent fluid from being withdrawn from the supply tank when the
|
|
irrigation system is either automatically or manually shut down.
|
|
5) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops, or in cases where there is
|
|
no water pump, when the water pressure decreases to the point where pesticide
|
|
distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection pump
|
|
(e.g., diaphragm pump), effectively designed and constructed of materials that are
|
|
compatible with pesticides and capable of being fitted with a system interlock.
|
|
7) Do not apply when wind speed favors drift beyond the area intended for treatment.
|
|
Pasteuria Bioscience, Inc. 17 of 28 15 July 2013
|
|
|
|
CProposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
Requirements for Sprinkler Chemigation:
|
|
1) The system must contain a functional check valve, vacuum relief valve, and low
|
|
pressure drain appropriately located on the irrigation pipeline to prevent water source
|
|
contamination from back flow.
|
|
2) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
3) The pesticide injection pipeline must also contain a functional, normally closed,
|
|
solenoid-operated valve located on the intake side of the injection pump and
|
|
connected to the system interlock to prevent fluid from being withdrawn from the
|
|
supply tank when the irrigation system is either automatically or manually shut down.
|
|
4) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops.
|
|
5) The irrigation line or water pump must include a functional pressure switch, which
|
|
will stop the water pump motor when the water pressure decreases to the point where
|
|
pesticide distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection pump
|
|
(e.g., diaphragm pump), effectively designed and constructed of materials that are
|
|
compatible with pesticides and capable of being fitted with a system interlock.
|
|
7) Do not apply when wind speed favors drift beyond the area intended for treatment.
|
|
Requirements for Drip Chemigation:
|
|
1) The system must contain a functional check valve, vacuum relief valve and
|
|
low pressure drain appropriately located on the irrigation pipeline to prevent water
|
|
source contamination from back flow.
|
|
2) The pesticide injection pipeline must contain a functional, automatic, quick-closing
|
|
check valve to prevent the flow of fluid back toward the injection pump.
|
|
3) The pesticide injection pipeline must also contain a functional, normally closed,
|
|
solenoid-operated valve located on the intake side of the injection pump and
|
|
connected to the system interlock to prevent fluid from being withdrawn from the
|
|
supply tank when the irrigation system is either automatically or manually shut down.
|
|
4) The system must contain functional interlocking controls to automatically shut off the
|
|
pesticide injection pump when the water pump motor stops.
|
|
5) The irrigation line or water pump must include a functional pressure switch, which
|
|
will stop the water pump motor when the; water pressure decreases to the point where
|
|
pesticide distribution is adversely affected.
|
|
6) Systems must use a metering pump, such as a positive displacement injection
|
|
pump (e.g., diaphragm pump), effectively designed and constructed of
|
|
materials that are compatible with pesticides and capable of being fitted with
|
|
a system interlock.
|
|
Pasteuria Bioscience, Inc. 18 of 28 15 July 2013
|
|
|
|
c cProposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
STORAGE AND DISPOSAL
|
|
Do not contaminate water, food, or feed by storage and disposal.
|
|
PESTICIDE STORAGE
|
|
Store refrigerated (~4°C). Reclose container of unused portions of SOYACYST™ LF.
|
|
PESTICIDE DISPOSAL
|
|
To avoid wastes, use all material in this container by application according to label directions.
|
|
If wastes cannot be avoided, offer remaining product to a waste disposal facility or pesticide
|
|
disposal program (often such programs are run by state or local governments or by industry).
|
|
CONTAINER HANDLING
|
|
[Plastic containers with capacities equal to or less than 5 gallons:] Nonrefillable container. Do
|
|
not reuse or refill this container. Triple rinse container (or equivalent) promptly after
|
|
emptying. Triple rinse as follows: Empty the remaining contents into application equipment
|
|
or a mix tank and drain for 10 seconds after the flow begins to drip. Fill the container 1/4 full
|
|
with water and recap. Shake for 10 seconds. Pour rinsate into application equipment or a mix
|
|
tank, or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to
|
|
drip. Repeat this procedure two more times. Then offer for recycling if available or puncture
|
|
and dispose of in a sanitary landfill, or by incineration. Do not burn, unless allowed by state
|
|
and local ordinance. If burned, stay out of smoke.
|
|
[Plastic containers with capacities greater than 5 gallons:] Nonrefillable container. Do not
|
|
reuse or refill this container. Triple rinse container (or equivalent) promptly after emptying.
|
|
Triple rinse as follows: Empty the remaining contents into application equipment or a mix
|
|
tank. Fill the container 1/4 full with water. Replace and tighten closures. Tip container on its
|
|
side and roll it back and forth, ensuring at least one complete revolution, for 30 seconds.
|
|
Stand the container on its end and tip it back and forth several times. Turn the container over
|
|
onto its other end and tip it back and forth several times. Empty the rinsate into application
|
|
equipment or a mix tank, or store rinsate for later use or disposal. Repeat this procedure two
|
|
more times. Then offer for recycling if available or puncture and dispose of in a sanitary
|
|
landfill, or by incineration. Do not burn, unless allowed by state and local ordinance. If
|
|
burned, stay out of smoke.
|
|
Pasteuria Bioscience, Inc. 19 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ LF
|
|
Sub-Label B
|
|
WARRANTY STATEMENT
|
|
Pasteuria Bioscience, Inc. (FBI) warrants that this product conforms to its label description
|
|
and is suitable for its intended use if stored and used in accordance with the Directions for
|
|
Use. To the extent consistent with applicable law, FBI makes no warranty, express or implied,
|
|
of merchantability, fitness or otherwise concerning the use of this product other than as
|
|
indicated on this label. To the extent consistent with applicable law, user assumes all risks of
|
|
use, storage or handling not in accordance with accompanying directions.
|
|
Pasteuria Bioscience, Inc. 20 of 28 15 July 2013
|
|
|
|
Proposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
SOYACYST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME:
|
|
SOYACYST™ST
|
|
Biological control for use on soybean seed against soybean cyst nematode
|
|
SUB-LABEL C
|
|
FOR SEED TREATMENT
|
|
Pasteuria Bioscience, Inc. 21 of 28 16 July 2013
|
|
|
|
r rProposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
SUB-LABEL C
|
|
SOYACYST™ LF
|
|
Biological control for use on soybean against soybean cyst nematode
|
|
WITH THE ALTERNATE BRAND NAME:
|
|
SOYACYST™ ST
|
|
Biological control for use on soybean seed against soybean cyst nematode
|
|
^> FOR ORGANIC PRODUCTION
|
|
Active Ingredient: Pasteuria nishizawae-fnl* 33.29%
|
|
Other Ingredients: 66.71%
|
|
Total: : 100.00%
|
|
* Contains at least least 2xl08 spores per g or 9.1xl010 spores per pound.
|
|
KEEP OUT OF REACH OF CHILDREN
|
|
CAUTION
|
|
See additional precautionary and first aid statements on the back panel
|
|
Net Contents: 2.5, 5, 10 or 15 gallons
|
|
EPA Registration Number: 85004-9
|
|
EPA Est. Number: 100-NC-002 or 70051-CA-001 or 88913-CHK-001
|
|
Manufactured for:
|
|
^PASTEURIAbioscience
|
|
12085 Research Dr., Suite 185 +1 (386) 462-0008
|
|
Alachua, FL 32615 www.pasteuriabio.com/
|
|
™ SOYACYST is a trademark of Pasteuria Bioscience, Inc.
|
|
Pasteuria Bioscience, Inc. 22 of 28 16 July 2013
|
|
|
|
f r aillt
|
|
Proposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
PRECAUTIONARY STATEMENTS
|
|
HAZARDS TO HUMANS AND DOMESTIC ANIMALS
|
|
CAUTION
|
|
Harmful if inhaled. Avoid breathing spray mist. Remove and wash contaminated clothing
|
|
before reuse.
|
|
FIRST AID
|
|
If inhaled:
|
|
Move person to fresh air.
|
|
If person is not breathing, call 911 or an ambulance, then give artificial
|
|
respiration, preferably mouth-to-mouth if possible.
|
|
Call a poison control center or doctor for treatment advice.
|
|
HOT LINE NUMBER
|
|
Have the product container or label with you when calling a poison control center or doctor,
|
|
or going for treatment. For emergency information concerning this product, call the National
|
|
Pesticide Information Center (NPIC) at 1-800-858-7378 seven days a week, 6:30 am to 4:30
|
|
pm Pacific Time. During other times, call your poison control center at 1-800-222-1222.
|
|
PERSONAL PROTECTIVE EQUIPMENT (PPE)
|
|
Applicators and other handlers must wear:
|
|
• Long-sleeved shirt and long pants
|
|
• Shoes plus socks
|
|
Mixers/loaders and applicators must wear a dust/mist filtering respirator meeting NIOSH
|
|
standards of at least N-95, R-95, or P-95. Repeated exposure to high concentrations of
|
|
microbial proteins can cause allergic sensitization.
|
|
Follow the manufacturer's instructions for cleaning/maintaining PPE. If no such instructions
|
|
are available, use detergent and hot water for washables. Keep and wash PPE separately from
|
|
other laundry.
|
|
Pasteuria Bioscience, Inc. 23 of 28 16 July 2013
|
|
|
|
rProposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
USER SAFETY RECOMMENDATIONS
|
|
Users should:
|
|
• Wash hands before eating, drinking, chewing gum, using tobacco or using the toilet.
|
|
• Remove clothing/PPE immediately if pesticide gets inside. Then wash thoroughly and
|
|
put on clean clothing.
|
|
• Remove PPE immediately after handling this product. As soon as possible, wash
|
|
thoroughly and change into clean clothing.
|
|
ENVIRONMENTAL HAZARDS
|
|
[Containers with capacities of 5 gallons or less:] For terrestrial uses, do not apply directly to
|
|
water, or to areas where surface water is present or to intertidal areas below the mean high
|
|
water mark.
|
|
Do not contaminate water when disposing of equipment wash waters or rinsate.
|
|
[Containers with capacities greater than 5 gallons:] Do not discharge effluent containing this
|
|
product into lakes, streams, ponds, estuaries, oceans, or other waters unless in accordance
|
|
with the requirements of a National Pollutant Discharge Elimination System (NPDES) permit
|
|
and the permitting authority has been notified in writing prior to discharge. Do not discharge
|
|
effluent containing this product to sewer systems without previously notifying the local
|
|
sewage treatment plant authority. For guidance, contact your State Water Board or Regional
|
|
Office of EPA.
|
|
For terrestrial uses, do not apply directly to water, or to areas where surface water is present
|
|
or to intertidal areas below the mean high water mark.
|
|
Do not contaminate water when disposing of equipment wash waters or rinsate.
|
|
DIRECTIONS FOR USE
|
|
It is a violation of Federal law to use this product in a manner inconsistent with its
|
|
labeling.
|
|
Do not use this product until you have read the entire label. Do not apply this product in a
|
|
way that will contact workers or other persons, either directly or through drift. Only protected
|
|
handlers may be in the area during application. For any requirement specific to your State or
|
|
Tribe, consult the State or Tribe agency responsible for pesticide regulation.
|
|
Pasteuria Bioscience, Inc. 24 of 28 16 July 2013
|
|
|
|
fProposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
AGRICULTURAL USE REQUIREMENTS
|
|
Use this product only in accordance with its labeling and with the Worker Protection
|
|
Standard, 40 CFR Part 170. This Standard contains requirements for the protection of
|
|
agricultural workers on farms, forests, nurseries, and greenhouses, and handlers of agricultural
|
|
pesticides. It contains requirements for training, decontamination, notification and emergency
|
|
assistance. It also contains specific instructions and exceptions pertaining to the statements
|
|
on this label about personal protective equipment (PPE) and restricted-entry interval. The
|
|
requirements in this box apply only to the uses of this product that are covered by the Worker
|
|
Protection Standard.
|
|
Do not enter or allow worker entry into treated areas during the restricted-entry interval (REI)
|
|
of 4 hours.
|
|
EXCEPTION: If the product is soil injected or soil incorporated, the Worker Protection
|
|
Standard, under certain circumstances, allows workers to enter the treated area if there will be
|
|
no contact with anything that has been treated.
|
|
PPE required for early entry to treated areas (that is permitted under the Worker Protection
|
|
Standard and that involves contact with anything that has been treated, such as plants, soil or
|
|
water) is:
|
|
• Water proof gloves
|
|
• Coveralls
|
|
• Shoes plus socks
|
|
NON- AGRICULTURAL USE REQUIREMENTS
|
|
The requirements in this box apply to uses of this product that are NOT within the scope
|
|
of the Worker Protection Standard for agricultural pesticides (40 CFR Part 170). The
|
|
WPS applies when this product is used to produce agricultural plants on farms, forests,
|
|
nurseries or greenhouses.
|
|
Keep unprotected persons out of treatment areas until seeds have dried or been packaged.
|
|
PRODUCT INFORMATION
|
|
This product contains a biological nematicide for the control of the following nematode:
|
|
Soybean Cyst Nematode Heterodera glycines
|
|
Pasteuria Bioscience, Inc. 25 of 28 16 July 2013
|
|
|
|
r rProposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
FOR USE AS A SEED TREATMENT
|
|
Treatment of highly mechanically scarred or damaged seed, or seed known to be of low vigor
|
|
and poor quality, except for the purpose of curative control of existing disease pests, may
|
|
result in reduced germination and/or reduction of seed and seedling vigor. Treat a small
|
|
quantity of seed using equipment similar to that planned for treating the total seed lot.
|
|
Conduct germination tests on a small portion of seed before committing the total seed lot to a
|
|
selected seed treatment. Due to seed quality, crop or variety sensitivity, and seed storage
|
|
conditions beyond the control of manufacturer, no claims are made to guarantee the
|
|
germination of carry-over seed or propagating material for all crop seed.
|
|
FOR USE AS A PRE-PLANT SEED TREATMENT
|
|
Treat only those seeds needed for immediate use, minimizing the interval between treatment
|
|
and planting. Do not store excess treated seeds beyond planting time.
|
|
To achieve improved application coverage to the seed, dilute SOYACYST™ LF with water
|
|
and apply directly to dry seed or mix with inoculants and/or other registered seed treatment
|
|
coatings (e.g., colorants, polymers, etc.), insecticides and fungicides. Dp not mix
|
|
SOYACYST™ LF with any product containing a label prohibition against such mixing.
|
|
When tank-mixing with any other registered seed treatment insecticide and/or fungicide,
|
|
always read and follow all use directions, restrictions, and precautions of both SOYACYST™
|
|
LF and the tank mix partner(s). The resulting tank mix must be in accordance with the more
|
|
restrictive label limitations and precautions. Do not exceed label dosage rates. Please consult
|
|
Pasteuria Bioscience, Inc. for additional information (http://www.pasteuriabio.com/).
|
|
SOYBEAN
|
|
For control of soybean cyst nematode, apply 2 to 12 fluid ounces of SOYACYST™ LF per
|
|
100 Lbs (60-150 mL per 45.4 kg) of soybean seed.
|
|
FOR USE AS A COMMERIGAL SEED TREATMENT
|
|
To achieve improved application coverage to the seed, dilute SOYACYST™ LF with water
|
|
and apply directly to dry seed or mix with inoculants and/or other registered seed treatment
|
|
coating (e.g., colorants, polymers, etc.), insecticides and fungicides. Do not mix
|
|
SOYACYST™ LF with any product containing a label prohibition against such mixing.
|
|
When tank-mixing with any other registered seed treatment insecticide and/or fungicide,
|
|
always read and follow all use directions, restrictions, and precautions of both SOYACYST™
|
|
LF and the tank mix partner(s). The resulting tank mix must be in accordance with the more
|
|
restrictive label limitations and precautions. Do not exceed label dosage rates. Please consult
|
|
Pasteuria Bioscience, Inc. for additional information (http://www.pasteuriabio.com/).
|
|
SOYBEAN
|
|
Pasteuria Bioscience, Inc. 26 of 28 16 July 2013
|
|
|
|
r rProposed Label for SOYACYST™ ST
|
|
Sub-label C
|
|
For control of soybean cyst nematode, apply 2 to 5 fluid ounces of SOYACYST™ LF per 100
|
|
Lbs (60-150 mL per 45.4 kg) of soybean seed.
|
|
STORAGE AND DISPOSAL
|
|
Do not contaminate water, food, or feed by storage and disposal.
|
|
PESTICIDE STORAGE
|
|
Store refrigerated (~4°C). Reclose container of unused portions of SOYACYST™ LF.
|
|
PESTICIDE DISPOSAL
|
|
To avoid wastes, use all material in this container by application according to label directions.
|
|
If wastes cannot be avoided, offer remaining product to a waste disposal facility or pesticide
|
|
disposal program (often such programs are run by state or local governments or by industry).
|
|
CONTAINER HANDLING
|
|
[Plastic containers with capacities equal to or less than 5 gallons:] Nonrefillable container. Do
|
|
not reuse or refill this container. Triple rinse container (or equivalent) promptly after
|
|
emptying. Triple rinse as follows: Empty the remaining contents into application equipment
|
|
or a mix tank and drain for 10 seconds after the flow begins to drip. Fill the container 1/4 full
|
|
with water and recap. Shake for 10 seconds. Pour rinsate into application equipment or a mix
|
|
tank, or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to
|
|
drip. Repeat this procedure two more times. Then offer for recycling if available or puncture
|
|
and dispose of in a sanitary landfill, or by incineration. Do not burn, unless allowed by state
|
|
and local ordinance. If burned, stay out of smoke.
|
|
[Plastic containers with capacities greater than 5 gallons:] Nonrefillable container. Do not
|
|
reuse or refill this container; Triple rinse container (or equivalent) promptly after emptying.
|
|
Triple rinse as follows: Empty the remaining contents into application equipment or a mix
|
|
tank. Fill the container 1/4 full with water. Replace and tighten closures. Tip container on its
|
|
side and roll it back and forth, ensuring at least one complete revolution, for 30 seconds.
|
|
Stand the container on its end and tip it back and forth several times. Turn the container over
|
|
onto its other end and tip it back and forth several times. Empty the rinsate into application
|
|
equipment or a mix tank, or store rinsate for later use or disposal. Repeat this procedure two
|
|
more times. Then offer for recycling if available or puncture and dispose of in a sanitary
|
|
landfill, or by incineration. Do not burn, unless allowed by state and local ordinance. If
|
|
burned, stay out of smoke.
|
|
Pasteuria Bioscience, Inc. 27 of 28 16 July 2013
|
|
|
|
cProposed Label for SOY ACYST™ ST ^
|
|
Sub-label C . ;
|
|
WARRANTY STATEMENT
|
|
Pasteuria Bioscience, Inc. (FBI) warrants that this product conforms to its label description
|
|
and is suitable for its intended use if stored and used in accordance with the Directions for
|
|
Use. To the extent consistent with applicable law, FBI makes no warranty, express or implied,
|
|
of merchantability, fitness or otherwise concerning the use of this product other than as
|
|
indicated on this label. To the extent consistent with applicable law, user assumes all risks of
|
|
use, storage or handling not in accordance with accompanying directions.
|
|
Pasteuria Bioscience, Inc. 28 of 28 16 July 2013
|