Dockerfile: self-contained image with corpus + Chroma + BM25 baked in. Drawbar's compose pulls + runs without volume mounts. Built from sources.json (labels schema), PRODUCT_NAME=crop_chem by default, HYBRID_SEARCH=true (always-on for production quality). RERANK_URL + OLLAMA_URL get set at compose time. .gitea/workflows/refresh.yml: monthly cron (1st @ 06:00 UTC) does full scrape → reindex → image push. Scrapes Bayer (~30 min) + EPA PPLS row-crop filtered (~7h). Skips reindex+push if no corpus diff. Tags pushed: :latest, :<sha12>, :corpus-<YYYY.MM.DD>. .gitea/workflows/image-only.yml: on-demand or auto on code-only pushes to main (paths: docs_mcp/, rag/, scrape/, requirements.txt, Dockerfile, sources.json). Reindexes from committed corpus, builds image, pushes. ~10 min vs ~9h full refresh. .gitignore: corpus/ now COMMITTED (4,159 labels, 265 MB of .md + sidecars). Lets image-only.yml rebuild indexes without re-scraping. chroma/ + bm25/ still gitignored (regenerable binary indexes). .dockerignore: drops venv, eval results, PLAN/README/CLAUDE.md, deploy/, .git/ — keeps the image lean. corpus + chroma + bm25 explicitly NOT in dockerignore (those go INTO the image). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
1338 lines
55 KiB
Markdown
1338 lines
55 KiB
Markdown
# DUPONT DPX-QFU31 (MP) HERBICIDE
|
|
|
|
- EPA Reg No: **352-761**
|
|
- Registrant: CORTEVA AGRISCIENCE, LLC
|
|
- Signal word: Warning
|
|
- Active ingredients: Dicamba, sodium salt (52.94%); Rimsulfuron (6.25%)
|
|
- Label accepted: 2011-07-26
|
|
- Source PDF: https://www3.epa.gov/pesticides/chem_search/ppls/000352-00761-20110726.pdf
|
|
|
|
---
|
|
rU.S. ENVIRONMENTAL PROTECTION AGENCY
|
|
Office of Pesticide Programs
|
|
Registration Division (7504P)
|
|
Ariel Rios Building
|
|
1200 Pennsylvania Ave., NW
|
|
Washington, O.C. 20460
|
|
NOTICE OF PESTICIDE:
|
|
X Registration
|
|
X Registration
|
|
(under FIFRA, as amended)
|
|
EPA Registration
|
|
Number:
|
|
352-761
|
|
Date of Issuance:
|
|
OUL 26 soil
|
|
Term of Issuance: Uncondjtjona|
|
|
Name of Pesticide Product:
|
|
DuPont Require Q (MP) Herbicide
|
|
Name and Address of Registrant (include ZIP Code):
|
|
DuPont Crop Protection
|
|
Stine-Haskell Research Center
|
|
P.O. Box 30
|
|
Newark, DE 19714-0030
|
|
On the basis of information furnished by the registrant, the above named pesticide is hereby registered/reregistered under the Federal Insecticide,
|
|
Fungicide and Rodenticide Act. Registration is in no way to be construed as an endorsement or recommendation of this product by the Agency. In
|
|
order to protect health and the environment, the Administrator, on his motion, may at any time suspend or cancel the registration of a pesticide in
|
|
accordance with the Act. The acceptance of any name in connection with the registration of a product under this Act is not to be construed as giving
|
|
the registrant a right to exclusive use of the name or to its use if it has been covered by others.
|
|
EPA received a label amendment request submitted on July 19, 2011. EPA grants this request
|
|
under the authority of section 3(c)(5) of the Federal Insecticide, Fungicide and Rodenticide Act, as
|
|
amended. With this accepted labeling, all requirements set forth in the Reregistation Eligibility
|
|
Decision (RED) for Dicamba have been satisfied. Therefore, EPA reregisters the product listed
|
|
above. This action is taken under the authority of section 4(g)(2)(c) of the Federal Insecticide,
|
|
Fungicide, and Rodenticide Act, as amended. Reregistration under this section does not eliminate
|
|
the need for continual reassessment of pesticides. EPA may require submission of data at any
|
|
time to maintain the registration of your product.
|
|
Submit one (1) copy of final printed labeling. Amended labeling will supersede all previously
|
|
accepted labels. A copy of your label stamped "Accepted" is enclosed for your records. Products
|
|
shipped after twelve (12) months from the date of this Notice or the next printing of your label,
|
|
whichever occurs first, must bear the new revised label.
|
|
If you have any questions regarding this Notice, please contact Beth Benbow at
|
|
(703) 347-8072 or at benbow.bethanv@epa.gov.
|
|
Signature of Approving Official:
|
|
Kathryn V. Monta
|
|
Product Manager
|
|
Herbicide Branch
|
|
Registration Division (7505P)
|
|
Date:
|
|
Jl)l 26 2011
|
|
EPA Form 8570-6
|
|
|
|
H-
|
|
DuPont™ Require® Q
|
|
(mp)
|
|
DRAFT LABEL
|
|
|
|
DuPont™
|
|
Require® Q (mp)
|
|
herbicide
|
|
A unit area pack product for
|
|
postemergence use in Field Corn
|
|
Active Ingredients By Weight
|
|
Rimsulfuron
|
|
N-((4,6-dimethoxypyrimidin-2-yl)
|
|
aminocarbonyl)-3-(ethylsulfonyl)-
|
|
2-pyridinesulfonamide 6.25%
|
|
Sodium salt of dicamba
|
|
(3,6-dichloro-2-methoxybenzoic acid)* 52.94%
|
|
Other Ingredients 40.81%
|
|
TOTAL 100.00%
|
|
* This product contains 48.12% 3,6-dichloro-2-
|
|
methoxybenzoic acid (dicamba). This product contains
|
|
0.004 pounds rimsulfuron per ounce and 0.03 pounds
|
|
dicamba (salt) per ounce.
|
|
EPA REG. NO. 352-761
|
|
Nonrefillable Container
|
|
Net:
|
|
OR
|
|
Refillable Container
|
|
Net:
|
|
EPA Est. No..
|
|
KEEP OUT OF REACH OF CHILDREN
|
|
WARNING/AVISOSi usted no entiende la etiqueta, busque a alguien para
|
|
que se la explique a usted en detalle. (If you do not
|
|
understand this label, find someone to explain it to you
|
|
in detail.)
|
|
FIRST AID
|
|
IF IN EYES: Hold eye open and rinse slowly and
|
|
gently with water for 15-20 minutes. Remove contact
|
|
lenses, if present, after the first 5 minutes, then continue
|
|
rinsing eye. Call a poison control center or doctor for
|
|
treatment advice.
|
|
IF ON SKIN OR CLOTHING: Take off contaminated
|
|
clothing. Rinse skin immediately with plenty of water
|
|
for 15-20 minutes. Call a poison control center or doctor
|
|
for treatment advice.
|
|
IF SWALLOWED: Call a poison control center or
|
|
doctor immediately for treatment advice. Have person
|
|
sip a glass of water if able to swallow. Do not induce
|
|
vomiting unless told to by a poison control center or
|
|
doctor. Do not give anything to an unconscious person.
|
|
IF INHALED: Move person to fresh air. If person is
|
|
not breathing, call 911 or an ambulance, then give
|
|
artificial respiration, preferably by mouth-to-mouth, if
|
|
possible. Call a poison control center or doctor for
|
|
further treatment advice.
|
|
Have the product container or label with you when
|
|
calling a poison control center or doctor, or going for
|
|
treatment. You may also contact 1-800-441-3637 for
|
|
emergency medical treatment information.
|
|
ACCiTf ED"
|
|
JUL 26 2011
|
|
TJndor the Federal Insecticide,
|
|
Fungicide, and Bodenwekis Act,
|
|
as amended, fo? the pesiloicte
|
|
regletersd under
|
|
PRECAUTIONARY STATEMENTS
|
|
HAZARDS TO HUMANS
|
|
AND DOMESTIC ANIMALS
|
|
WARNING! Causes substantial but temporary eye
|
|
injury. Wear protective eyewear. Harmful if swallowed
|
|
or absorbed through skin. Prolonged or frequently
|
|
repeated skin contact may cause allergic reactions in
|
|
some individuals. Do not get in eyes or on clothing.
|
|
Avoid contact with skin. Avoid breathing dust or spray
|
|
mist. Wash thoroughly with soap and water after
|
|
handling and before eating, drinking, chewing gum, or
|
|
using tobacco. Remove and wash contaminated clothing
|
|
before reuse.
|
|
PERSONAL PROTECTIVE EQUIPMENT (PPE)
|
|
Some of the materials that are chemical resistant to this
|
|
product are listed below. If you want more options
|
|
follow the instructions for category A on an EPA
|
|
chemical-resistant category selection chart.
|
|
All mixers, loaders, and applicators and other
|
|
handlers must wear:
|
|
Long-sleeve shirt and long pants.
|
|
Chemical resistant gloves Category A (such as butyl
|
|
rubber, natural rubber, neoprene rubber, or nitrile
|
|
rubber), all > 14 mils..
|
|
Shoes plus socks.
|
|
Protective eyewear
|
|
See Engineering Controls Statements for additional
|
|
requirements and exceptions.
|
|
Discard clothing and other absorbent materials that have
|
|
been drenched or heavily contaminated with this
|
|
product's concentrate. Do not reuse them. Follow
|
|
manufacturer's instructions for cleaning/maintaining PPE.
|
|
If no such instructions for washables exist, use detergent
|
|
and hot water. Keep and wash PPE separately from other
|
|
laundry.
|
|
ENGINEERING CONTROL STATEMENTS
|
|
When handlers use closed systems, enclosed cabs, or
|
|
aircraft in a manner that meets the requirements listed in
|
|
the Worker Protection Standard (WPS) for agricultural
|
|
pesticides [40 CFR part 170.240 (d)(4-6)], the handler
|
|
PPE requirements may be reduced or modified as
|
|
specified in the WPS. Pilots must use cockpits in a
|
|
manner that meets the requirements listed in the Worker
|
|
Protection Standard (WPS) for agricultural pesticides [40
|
|
CFR part 170.240 (d)(4-6)].
|
|
USER SAFETY RECOMMENDATIONS
|
|
USERS SHOULD: Wash hands before eating,
|
|
drinking, chewing gum, using tobacco or using the
|
|
toilet. Remove clothing/PPE immediately if pesticide
|
|
gets inside. Then wash thoroughly and put on clean
|
|
clothing. Remove PPE immediately after handling
|
|
this product. Wash the outside of gloves before
|
|
removing. As soon as possible, wash thoroughly and
|
|
change into clean clothing.
|
|
|
|
ENVIRONMENTAL HAZARDS
|
|
Do not apply directly to water, or to areas where surface
|
|
water is present, or to intertidal areas below the mean
|
|
high water mark. Do not contaminate water by cleaning
|
|
of equipment or disposal of equipment washwaters or
|
|
rinsate. Keep out of lakes, streams, or ponds. Apply this
|
|
product only as directed on the label.
|
|
Dicamba is known to leach through soil into ground
|
|
water under certain conditions as a result of agricultural
|
|
use. Use of this product in areas where soils are
|
|
permeable, particularly where the water table is shallow,
|
|
may result in ground water contamination.
|
|
DO NOT discharge effluent containing this product into
|
|
lakes, streams, ponds, estuaries, oceans, or other waters
|
|
unless in accordance with the requirements of a National
|
|
Pollution Discharge Elimination System (NPDES) permit
|
|
and the permitting authority has been notified in writing
|
|
prior to discharge. DO NOT discharge effluent containing
|
|
this product to sewer systems without previously
|
|
notifying the local sewage treatment plant authority. For
|
|
guidance, contact your State Water Board or Regional
|
|
Office of the EPA.
|
|
Ground and Surface Water Protection
|
|
Point source contamination: To prevent point source
|
|
contamination, do not mix, load this pesticide product
|
|
within 50 feet of wells (including abandoned wells and
|
|
drainage wells), sink holes, perennial or intermittent
|
|
streams and rivers, and natural or impounded lakes and
|
|
reservoirs. Do not apply pesticide product within 50 feet
|
|
of wells. This setback does not apply to properly capped
|
|
or plugged abandoned wells and does not apply to
|
|
impervious pad or properly diked mixing/loading areas as
|
|
described below. Mixing, loading, rinsing, or washing
|
|
operations performed within 50 feet of a well are allowed
|
|
only when conducted on an impervious pad constructed
|
|
to withstand the weight of the heaviest load that may be
|
|
on or move across the pad. The pad must be self-
|
|
contained to prevent surface water flow over or from the
|
|
pad. The pad capacity must be maintained at 110% that of
|
|
the largest pesticide container or application equipment
|
|
used on the pad and have sufficient capacity to contain all
|
|
product spills, equipment or container leaks, equipment
|
|
wash waters, and rainwater that may fall on the pad. The
|
|
containment capacity does not apply to vehicles
|
|
delivering pesticide shipments to the mixing/loading site.
|
|
States may have in effect additional requirements
|
|
regarding wellhead setbacks and operational containment.
|
|
Care must be taken when using this product to prevent: a)
|
|
back siphoning into wells, b) spills or c) improper
|
|
disposal of excess pesticide, spray mixtures or rinsates.
|
|
Check valves or antisiphoning devices must be used on
|
|
all mixing equipment.
|
|
Movement by surface runoff or through soil: Do not
|
|
apply under conditions which favor runoff. Do not apply
|
|
to impervious substrates such as paved or highly
|
|
compacted surfaces in areas with high potential for
|
|
ground water contamination. Ground water
|
|
contamination may occur in areas where soils are
|
|
permeable or coarse and ground water is near the surface.
|
|
Do not apply to soils classified as sand with less than 3%
|
|
organic matter and where ground water depth is shallow.
|
|
To minimize the possibility of ground water
|
|
contamination, carefully follow application rate
|
|
recommendations as affected by soil type in the general
|
|
information section of this label.
|
|
Movement by water erosion of treated soil: Do not
|
|
apply or incorporate this product through any type of
|
|
irrigation equipment nor by flood or furrow irrigation.
|
|
Ensure treated areas have received at least one-half inch
|
|
rainfall (or irrigation) before using tailwater for
|
|
subsequent irrigation of other fields.
|
|
Endangered Species Concerns
|
|
The use of any pesticide in a manner that may kill or
|
|
otherwise harm an endangered species or adversely
|
|
modify their habitat is a violation of federal law.
|
|
DIRECTIONS FOR USE
|
|
It is a violation of Federal law to use this product in a manner
|
|
inconsistent with its labeling.
|
|
Do not apply this product in a way that will contact workers or
|
|
other persons, either directly or through drift. Only protected
|
|
handlers may be in the area during application. For any
|
|
requirements specific to your State or Tribe, consult the agency
|
|
in your State responsible for pesticide regulation.
|
|
AGRICULTURAL USE REQUIREMENTS
|
|
Use this product only in accordance with its labeling and
|
|
with the Worker Protection Standard, 40 CFR part 170.
|
|
This Standard contains requirements for the protection of
|
|
agricultural workers on farms, forests, nurseries, and
|
|
greenhouses, and handlers of agricultural pesticides. It
|
|
contains requirements for training, decontamination,
|
|
notification, and emergency assistance. It also contains
|
|
specific instructions and exceptions pertaining to the
|
|
statements on this label about personal protective
|
|
equipment (PPE) and restricted-entry interval. The
|
|
requirements in this box only apply to uses of this
|
|
product that are covered by the Worker Protection
|
|
Standard.
|
|
Do not enter or allow worker entry into treated areas
|
|
during the restricted entry interval (REI) of 24 hours.
|
|
Exception: If the product is soil injected or soil
|
|
incorporated, the Worker Protection Standard, under
|
|
certain circumstances, allows workers to enter the treated
|
|
areas if there will be no contact with anything that has
|
|
been treated. PPE required for early entry to treated areas
|
|
that is permitted under the Worker Protection Standard
|
|
and that involves contact with anything that has been
|
|
treated, such as plants, soil, or water, is:
|
|
- Coveralls worn over short-sleeve shirt and short pants
|
|
- Chemical-resistant footwear plus socks
|
|
- Chemical-resistant gloves, category A (such as butyl
|
|
rubber, natural rubber, neoprene rubber, or nitrile
|
|
rubber), all > 14 mils.
|
|
- Chemical-resistant headgear for overhead exposure
|
|
- Protective eyewear.
|
|
Notify workers of the application by warning them
|
|
orally and by posting warning signs at entrances to
|
|
treated areas.
|
|
PRODUCT INFORMATION
|
|
DuPont™ REQUIRE® Q (mp) herbicide must be used only
|
|
in accordance with instructions on this label or in
|
|
supplemental DuPont publications. DuPont will not be
|
|
responsible for losses or damage resulting from use of this
|
|
product in any manner not specified by DuPont.
|
|
|
|
r
|
|
DuPont™ REQUIRE® Q (mp) herbicide is a unit area pack
|
|
herbicide that is used at the rate of 4 ounces per acre for
|
|
burndown and residual control of certain annual grass and
|
|
broadleaf weeds when applied preemergence and
|
|
postemergence. One 80 ounce unit area pack will treat 20
|
|
acres at the 4 ounce per acre application rate. After opening
|
|
the REQUIRE® Q (mp) herbicide package, you must
|
|
completely empty the entire contents of both compartments
|
|
into the spray tank.
|
|
REQUIRE® Q (mp) may be applied to "Roundup Ready"
|
|
corn in tank mix combinations with glyphosate herbicides
|
|
such as "Roundup Original", "Roundup Weathermax", or
|
|
similar products to add residual control for later emerging
|
|
weeds. Residual weed control is dependent on rainfall or
|
|
sprinkler irrigation for herbicide activation.
|
|
supplemental labeling information relative to potential corn
|
|
hybrid sensitivity to REQUIRE® Q (mp).
|
|
APPLICATION INFORMATION
|
|
WHEN TO APPLY
|
|
;sMi*«r*Si'ifeaw»**>i^iJryvv-r3gi'j,.-t ''•'5»L«;,«sm?r.',.3;i 'st'ji's.-hv
|
|
Ofauliolasltolaloicl
|
|
REQUIRE® Q (mp) can be applied to many field corn
|
|
hybrid with a relative maturity (RM) of 77 days or more.
|
|
Consult with your seed supplier before applying
|
|
REQUIRE® Q (mp) to any corn types where specific seed
|
|
company publications indicate "Warning", "Crop Response
|
|
Warning", or "Sensitive" notations for the use of some ALS
|
|
herbicides. As noted in the seed company publications,
|
|
DuPont sulfonylurea herbicides such as REQUIRE® Q
|
|
(mp) should be used with caution on these hybrids. DuPont
|
|
does not have access to all seed company data.
|
|
Consequently, injury arising from the use of REQUIRE® Q
|
|
(mp) herbicide on the above types of hybrids is the
|
|
responsibility of the user. Consult with your local DuPont
|
|
representative or the DuPont Label Web Site
|
|
(http://cropprotection.dupont.com/) for any additional
|
|
Fallow
|
|
Use rates
|
|
Apply REQUIRE® Q (mp) at 4 ounces per acre. One unit
|
|
area pack will treat 20 acres at this application rate.
|
|
Application Timing
|
|
REQUIRE® Q (mp) may be used as a fallow treatment, in
|
|
the spring or fall when the majority of weeds have emerged
|
|
and are actively growing.
|
|
Tank Mixtures in Fallow
|
|
REQUIRE® Q (mp) may be used as a fallow treatment and
|
|
may be tank mixed with other herbicides that are registered
|
|
for use in fallow. Read and follow all instructions on this
|
|
label and the labels of any tank mix partner before using any
|
|
other herbicide in mixtures with REQUIRE® Q (mp). If the
|
|
recommendations on the tank mix partner label conflict with
|
|
this REQUIRE® Q (mp) label, do not use in a tank mixture
|
|
with REQUIRE® Q (mp).
|
|
Field Corn
|
|
Up to 2 applications of REQUIRE® Q (mp) herbicide may
|
|
be made during a growing season. Sequential applications
|
|
must be separated by 2 weeks or more.
|
|
WHEN TO APPLY - Preemergence to the Crop
|
|
Apply REQUIRE® Q (mp) at 4.0 ounce per acre before
|
|
corn emergence. See cumulative rimsulfuron rate limitation
|
|
as noted above. Consult DuPont technical bulletins, fact
|
|
sheets or supplemental labeling for additional application
|
|
rate information.
|
|
REQUIRE® Q (mp) herbicide may be used in either
|
|
conventional, conservation tillage, or no-till crop
|
|
management systems and may be applied either preplant,
|
|
preplan! incorporated (less than 2" deep), preemergence, or
|
|
post emergence for use in field corn production.
|
|
Applications of REQUIRE® Q (mp) made before weed
|
|
emergence will provide residual control of labeled weeds.
|
|
Control of emerged weeds will require the addition of spray
|
|
adjuvants, and can be further enhanced with additional tank
|
|
mix partners as noted in this label.
|
|
Preplant Surface Applied - REQUIRE® Q (mp) may be
|
|
applied up to 30 days prior to planting. REQUIRE® Q
|
|
(mp) is best used in a planned sequential application
|
|
program, followed by REQUIRE® Q (mp), Steadfast Q,
|
|
tank mixed with appropriate corn herbicide partners post
|
|
applied. Refer to the label of the respective sequential
|
|
partner for specific use directions.
|
|
Preplant/Preemerge Burndown - REQUIRE® Q (mp) may
|
|
be applied when weeds are present at the time of treatment
|
|
in a tank mixture with crop oil concentrate or methylated
|
|
|
|
r
|
|
seed oil for burndown of labeled weeds 3" or less in height.
|
|
When weeds are greater than 3" in height or weeds not
|
|
controlled by DuPont™ REQUIRE® Q (mp) are present,
|
|
the addition of burndown herbicide (ie glyphosate,
|
|
gramoxone, dicamba, and/or 2, 4-D) is recommended. If
|
|
giant ragweed, common cocklebur, henbit, Pennsylvania
|
|
smartweed or purple deadnettle are present at the time of
|
|
application, the addition of atrazine will improve control.
|
|
Observe direction for use and precaution and restrictions on
|
|
the label of the burndown herbicide. When mixing with
|
|
liquid nitrogen fertilizer or glyphosate, substitute a non-
|
|
ionic surfactant for crop oil.
|
|
WHEN TO APPLY- Postemergence to the Crop
|
|
Apply REQUIRE® Q (mp) any time after corn has reached
|
|
4 inches in height (V2). Do not apply to corn taller than 20
|
|
inches or exhibiting 7 or more leaf collars, whichever is
|
|
more restrictive. Applications of REQUIRE® Q (mp) made
|
|
after weed emergence will provide contact control of
|
|
labeled weeds as well as limited residual control of later
|
|
emergence.
|
|
Postemergence Rates
|
|
REQUIRE® Q (mp) is to be applied at 4 oz/acre as a
|
|
postemergence broadcast application. Consult DuPont
|
|
technical bulletins or Supplemental Labeling for additional
|
|
rate instructions.
|
|
Timing to Weeds
|
|
• Tank mixtures of REQUIRE® Q (mp) with glyphosate or
|
|
glufosinate herbicides may be applied after weeds emerge
|
|
but before they reach the maximum size listed on the
|
|
glyphosate or glufosinate herbicide labels.
|
|
• Adequate soil moisture is required for optimum activity.
|
|
Rainfall within 7 days after application will enhance
|
|
REQUIRE® Q (mp) residual activity. If activating rainfall
|
|
or sprinkler irrigation (>0.5 inch) is not received within 7
|
|
days after application, follow with a cultivation or with a
|
|
sequential application of DuPont™ ACCENT® herbicide,
|
|
if needed.
|
|
RATE
|
|
REQUIRE® Q (mp) is a unit area pack product which will
|
|
treat 20 acres of corn as a broadcast application.
|
|
Apply REQUIRE® Q (mp) at a rate of 4 ounces per acre for
|
|
control or suppression of the grasses and broadleaf weeds
|
|
listed below.
|
|
SPRAY ADJUVANTS
|
|
For control of emerged weeds, application of REQUIRE®
|
|
Q (mp) must include a nonionic surfactant and an
|
|
ammonium nitrogen fertilizer. If applied in tank mix
|
|
combination with a glyphosate or glufosinate herbicide that
|
|
contains a built-in adjuvant system, such as "Roundup
|
|
Weathermax" or "Liberty", no additional surfactant needs to
|
|
be added. Crop oil concentrate may be used in place of
|
|
nonionic surfactant for burndown applications of
|
|
REQUIRE® Q (MP) made before crop emergence. Consult
|
|
local DuPont fact sheets, technical bulletins, and service
|
|
policies prior to using other adjuvant systems. Products
|
|
must contain only EPA-exempt ingredients (40 CFR 1001).
|
|
Petroleum Crop Oil Concentrate (COO or Modified Seed
|
|
Oil (MSO)
|
|
• Apply at 1% v/v (1 gallon per 100 gallons spray solution)
|
|
or 2% under arid conditions.
|
|
• MSO adjuvants may be used at 0.5% v/v (0.5 gallon per
|
|
100 gallons spray solution) if specifically noted on
|
|
adjuvant product labeling.
|
|
• Oil adjuvants must contain at least 80% high quality,
|
|
petroleum (mineral) or modified vegetable seed oil with
|
|
at least 15% surfactant emulsifiers.
|
|
Nonionic Surfactant (NIS)
|
|
• Apply at 0.25% v/v (1 qt per 100 gal spray solution).
|
|
• Surfactant products must contain at least 60% nonionic
|
|
surfactant with a hydrophilic/lipophilic balance (HLB)
|
|
greater than 12.
|
|
Ammonium Nitrogen Fertilizer
|
|
• Use 2 qt/acre of a high-quality urea ammonium nitrate
|
|
(UAN) such as 28%N or 32%N, or 2 Ib/acre of a spray-
|
|
grade ammonium sulfate (AMS).
|
|
• Do not use liquid nitrogen fertilizer as the total carrier
|
|
solution after crop emergence.
|
|
Special Adjuvant Types
|
|
• Combination adjuvant products may be used at doses that
|
|
provide the required amount of NIS and ammonium
|
|
nitrogen fertilizer. Consult product literature for use rates
|
|
and restrictions.
|
|
WEEDS CONTROLLED/SUPPRESSED
|
|
POSTEMERGENCE CONTROL
|
|
Grasses (1 - 2")
|
|
Barley, volunteer
|
|
Barnyardgrass
|
|
Bluegrass, annual
|
|
Crabgrass, large (1/2")
|
|
Cupgrass, woolly (1")
|
|
Foxtail (bristly, giant, green, yellow)
|
|
Johnsongrass, seedling*
|
|
Millet, Wild Proso*
|
|
Panicum, fall
|
|
Quackgrass*
|
|
Ryegrass, Italian*
|
|
Shattercane (4")
|
|
Signalgrass, broadleaf*
|
|
Stinkgrass*
|
|
Wheat, volunteer
|
|
Wild oat*
|
|
Yellow nutsedge*
|
|
* partial control/suppression
|
|
|
|
Broadleaves (1 - 3")
|
|
Alfalfa, volunteerA
|
|
Amaranth, Palmer*
|
|
Canada thistle*
|
|
Chickweed, common
|
|
Cocklebur*
|
|
Dandelion (6" diameter)
|
|
Henbit
|
|
Jimsonweed*
|
|
Kochia
|
|
Ladysthumb*
|
|
Lambsquarters, common*
|
|
Morningglory, (ivyleaf, tall*)
|
|
Mustard, (birdsrape, black, wild)
|
|
Nightshade, (hairy, Eastern black*)
|
|
Pigweed, (prostrate, redroot, smooth)
|
|
Purslane, common*
|
|
Ragweed, (common*, giant*)
|
|
Russian thistle
|
|
Shepherd's purse
|
|
Sicklepod*
|
|
Smartweed, Pennsylvania*
|
|
Waterhemp*
|
|
Wild radish
|
|
Wild sunflower
|
|
Velvetleaf
|
|
*partial control/suppression
|
|
A Except in California
|
|
RESIDUAL CONTROL
|
|
Grasses
|
|
Barnyardgrass
|
|
Bluegrass, annual*
|
|
Crabgrass, large*
|
|
Foxtail (bristly, giant, green, yellow)
|
|
Panicum, fall*
|
|
Signalgrass, broadleaf*
|
|
Wheat, Volunteer
|
|
Wild Oat*
|
|
* partial control/suppression
|
|
Broadleaves
|
|
Carpetweed*
|
|
Chamomile, false
|
|
Cocklebur*
|
|
Filaree, Redstem
|
|
Henbit
|
|
Jimsonweed*
|
|
Kochia (ALS-sensitive)
|
|
Lambsquarters, common
|
|
Morningglory, ivyleaf*
|
|
Mustard (birdsrape, black)
|
|
Nightshade* (hairy, black)
|
|
Palmer amaranth*
|
|
Pigweed (prostrate, redroot, smooth)
|
|
Purslane, common
|
|
Ragweed, common*
|
|
Russian thistle, seedling*
|
|
Smartweed, Pennsylvania*
|
|
Velvetleaf*
|
|
* partial control/suppression
|
|
TANK MIXTURES
|
|
DuPont™ REQUIRE® Q (mp) may be tank mixed with full
|
|
or reduced rates of other product registered for use in corn.
|
|
Read and follow all manufactures label recommendations
|
|
for the companion herbicide. If these recommendations
|
|
conflict with this REQUIRE® Q (mp) label, do not use as a
|
|
tank mixture with REQUIRE® Q (mp).
|
|
Postemergence to the Crop
|
|
Tank Mixtures with Glyphosate
|
|
REQUIRE® Q (mp) may be tank mixed with glyphosate
|
|
herbicides if applications are made to corn hybrids
|
|
containing the "Roundup Ready" gene. Consult with your
|
|
seed supplier to confirm the corn hybrid is "Roundup
|
|
Ready" before making any herbicide application containing
|
|
glyphosate herbicides.
|
|
When used in tank mixture with glyphosate herbicides, 4 oz
|
|
REQUIRE® Q (mp) will deliver improved burndown and/or
|
|
residual activity on the following weeds, as compared to
|
|
glyphosate used alone:
|
|
Alfalfa, volunteer*
|
|
Barley, volunteer
|
|
Barnyardgrass
|
|
Bluegrass, annual
|
|
Canada thistle
|
|
Chamomile, false
|
|
Chickweed, common
|
|
Cocklebur
|
|
Crabgrass
|
|
Dandelion (6" diameter)
|
|
Filaree, redstem
|
|
Foxtail (bristly, giant, green, yellow)
|
|
Henbit
|
|
Johnsongrass, seedling
|
|
Kochia
|
|
Lambsquarters, common
|
|
Millet, wild proso
|
|
Morningglory, (ivyleaf, tall)
|
|
Mustard (birdsrape, black, wild)
|
|
Nightshade, hairy
|
|
Panicum, fall
|
|
Pigweed (prostrate, redroot, smooth)
|
|
Purslane, common
|
|
Quackgrass
|
|
Ragweed, (common, giant)
|
|
Ryegrass, Italian
|
|
Sandbur (field, longspine)
|
|
Shepherd's purse
|
|
Signalgrass, broadleaf
|
|
Smartweed, Pennsylvania
|
|
Stinkgrass
|
|
Velvetleaf
|
|
Waterhemp
|
|
Wheat, volunteer
|
|
Wild buckwheat
|
|
Wild oat
|
|
Wild radish
|
|
Yellow nutsedge
|
|
* Except in California
|
|
Tank Mixtures with Glufosinate
|
|
REQUIRE® Q (mp) may be tank mixed with glufosinate
|
|
herbicides if applications are made to corn hybrids
|
|
containing the "Liberty Link" gene. Consult with your seed
|
|
supplier to confirm the corn hybrid is "Liberty Link" before
|
|
applying any herbicide containing glufosinate.
|
|
When used in tank mixtures with glufosinate herbicide, 4 oz
|
|
REQUIRE® Q (mp) will deliver improved burndown
|
|
and/or limited residual activity of several broadleaf and
|
|
grass weeds including velvetleaf, redroot pigweed, common
|
|
lambsquarters, and certain foxtail spp. as compared to
|
|
glufosinate alone.
|
|
For Additional Control of Kochia
|
|
REQUIRE® Q (mp) may be tank mixed with 1/3 to 2/3 pint
|
|
per acre of "Starane" for improved control of kochia. Use
|
|
higher rates when weed infestation is heavy. Refer to the
|
|
specific "Starane" label for application timing and
|
|
restrictions.
|
|
For Additional Control of Broadleaf and Grass Weeds
|
|
REQUIRE® Q (mp) may be tank mixed with full or reduced
|
|
rates of preemergence grass and broadleaf herbicides such as
|
|
atrazine, DuPont™ CINCH®, DuPont™ CINCH® ATZ,
|
|
|
|
DuPont™ BREAKFREE®, DuPont™ BREAKFREE® ATZ,
|
|
or "Outlook" to provide added residual activity or burndown
|
|
activity on emerged weeds. Consult tank mix partner labeling
|
|
for application rates, adjuvant recommendations, and soil-type
|
|
restrictions.
|
|
DuPont™ REQUIRE® Q (mp) may be tank mixed with 2
|
|
pints per acre of "Lumax" or 2 1/3 pints per acre of "Lexar"
|
|
for improved burndown or residual control of several
|
|
broadleaf weeds including common waterhemp, common
|
|
ragweed, common lambsquarters, and velvetleaf. When
|
|
applying mixtures of REQUIRE® Q (mp) plus "Lumax" or
|
|
"Lexar" the use of a nonionic surfactant is recommended.
|
|
Refer to "Lumax" or "Lexar" labels for additional
|
|
information regarding application timing, tank mixtures,
|
|
adjuvants, and rotational crops.
|
|
REQUIRE® Q (mp) may be tank mixed with 0.5 to 0.75
|
|
fluid ounces per acre of "Impact" plus atrazine at 0.375 to
|
|
1.5 pounds active per acre for improved burndown or
|
|
residual control of several broadleaf weeds including
|
|
common waterhemp, common ragweed, common
|
|
lambsquarters, and velvetleaf. When applying mixtures of
|
|
REQUIRE® Q (mp) plus "Impact" the use of methylated
|
|
seed oil is recommended. Refer to "Impact" label for
|
|
additional information regarding application timing, tank
|
|
mixtures, adjuvants, and rotational crops.
|
|
FOR ALL APPLICATION TIMINGS
|
|
:^S9^l»f!ISaa!^jSKSS^n^S^S^!SaSf^SS^Sil:
|
|
^itKiffl^^PayslSulti!
|
|
Other than the exceptions noted, and in addition to the tank
|
|
mix partners indicated in the fallow and postemergence
|
|
sections above, REQUIRE® Q (mp) may be applied in tank
|
|
mixture with glyphosate plus other products registered for
|
|
use in field corn. REQUIRE® Q (mp) may be applied in
|
|
tank mix combinations with full or reduced rates of other
|
|
products provided:
|
|
• The tank mix product is labeled for the same timing,
|
|
method of application, adjuvants, and use restrictions as
|
|
REQUIRE® Q (mp) and other products used in the tank
|
|
mixture.
|
|
• The tank mixture is not specifically prohibited on the label
|
|
of the tank mix product.
|
|
Tank Mixing Precautions:
|
|
• Weed control and crop response with tank mixtures not
|
|
specifically recommended in this label or in REQUIRE®
|
|
Q (mp) fact sheets or technical bulletins are the
|
|
responsibility of the user and manufacturer of the tank
|
|
mix product.
|
|
• Read and follow all applicable use directions, precautions,
|
|
and limitations specified on the respective product labels
|
|
and fact sheets.
|
|
CHEMIGATION
|
|
Do not apply REQUIRE® Q (mp) through any type of irrigation
|
|
system.
|
|
MIXING INSTRUCTIONS
|
|
1. Fill the tank 1/4 to 1/3 full of water.
|
|
2. While agitating, add the required amount of REQUIRE®
|
|
Q (mp).
|
|
3. Continue agitation until the REQUIRE® Q (mp) is fully
|
|
dispersed, at least 5 minutes.
|
|
4. Once the REQUIRE® Q (mp) is fully dispersed, maintain
|
|
agitation and continue filling tank with water.
|
|
REQUIRE® Q (mp) should be thoroughly mixed with
|
|
water before adding any other material.
|
|
5. As the tank is filling, add tank mix partners (if desired).
|
|
6. If the mixture is not continuously agitated, settling will
|
|
occur. If settling occurs, thoroughly re-agitate before
|
|
using.
|
|
7. Apply REQUIRE® Q (mp) spray mixture within 48 hours
|
|
of mixing to avoid product degradation.
|
|
BROADCAST APPLICATION
|
|
Use a minimum of 15 gallons of water per acre (GPA) to
|
|
ensure thorough coverage of the weeds and the best
|
|
performance. Use a minimum of 10 GPA for light, scattered
|
|
stands of weeds. For best performance, select nozzles and
|
|
pressure that deliver MEDIUM spray droplets, as indicated,
|
|
for example, by ASAE Standard S572. Nozzles that deliver
|
|
COARSE spray droplets may be used to reduce drift, provided
|
|
spray volume is increased to maintain coverage on small
|
|
weeds.
|
|
For optimal product performance and minimal spray drift,
|
|
adjust the spray boom to the lowest possible spray height
|
|
recommended in manufacturers' specifications. Ensure that
|
|
equipment is set up to avoid applying an excessive rate directly
|
|
over the rows and into the corn plant whorl. Overlaps or
|
|
starting, stopping, slowing, and turning while spraying may
|
|
result in crop injury.
|
|
AERIAL APPLICATION
|
|
Aerial application is not permitted in the State of New York.
|
|
Use nozzle types and arrangements that will provide optimum
|
|
spray distribution and maximum coverage at a minimum of 5
|
|
GPA.
|
|
|
|
f
|
|
Do not apply during a temperature inversion, when winds are
|
|
gusty, or when conditions favor poor coverage and/or off-
|
|
target spray movement.
|
|
ENVIRONMENTAL CONDITIONS
|
|
AND BIOLOGICAL ACTIVITY
|
|
DuPont™ REQUIRE® Q (mp) is absorbed through the shoots
|
|
and roots of plants, rapidly inhibiting the growth of susceptible
|
|
weeds. Rainfall or sprinkler irrigation is needed to move
|
|
REQUIRE® Q (mp) into the soil. Susceptible weeds will
|
|
generally not emerge from preemergence application. In some
|
|
cases susceptible weeds may germinate and emerge a few days
|
|
after application, but growth then ceases and leaves become
|
|
chlorotic three to five days after emergence. Death of leaf
|
|
tissue and growing point will follow in some species, while
|
|
others will remain green but stunted and noncompetitive.
|
|
The herbicidal action of REQUIRE® Q (mp) may be less
|
|
effective on weeds stressed from adverse environmental
|
|
conditions (such as extreme temperatures or moisture),
|
|
abnormal soil conditions, or cultural practices. Rainfall within
|
|
4 hours after a postemergence application of DuPont™
|
|
REQUIRE® Q (mp) may reduce herbicidal activity.
|
|
REQUIRE® Q (MP) ROTATIONAL CROP
|
|
GUIDELINES
|
|
The following rotational intervals should be observed when
|
|
using REQUIRE® Q (mp):
|
|
4 OZ MAXIMUM USE RATE PER SEASON
|
|
Rotation Crop Interval (months)
|
|
8 OZ MAXIMUM USE RATE PER SEASON
|
|
Rotation Crop Interval (months)
|
|
Corn, field
|
|
Potatoes
|
|
STS soybeans***
|
|
Tomato
|
|
Cereals, Winter (wheat)
|
|
Cereals, Spring (wheat, oats, barley)
|
|
Alfalfa*t
|
|
Cottont
|
|
Canolaf
|
|
Cucumber*
|
|
Flax
|
|
Peas
|
|
Rice**
|
|
Red Clovert
|
|
Sorghumf
|
|
Com, pop or sweet
|
|
Soybeans
|
|
Snap beans, dry beans
|
|
Sunflower
|
|
Sugarbeetst
|
|
Crops Not Listed
|
|
Anytime
|
|
4
|
|
1
|
|
4
|
|
3
|
|
9
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
18
|
|
* On sprinkler irrigated fields in Idaho, Utah, and Northern Nevada it
|
|
is best to use deep fall tillage such as plowing prior to planting
|
|
alfalfa. Product degradation may be less on furrow irrigated soils
|
|
and may result in some crop injury.
|
|
t 18 months in the Red River Valley region of ND and MN. In all
|
|
other areas, the rotation intervals should be extended to 18 months if
|
|
drought conditions prevail after application and before the rotational
|
|
crop is planted, unless sprinkler irrigation has been applied and totals
|
|
greater than 15" during the growing season.
|
|
**For soils with pH less than 6.5.
|
|
***Sulfonylurea Tolerant Soybean
|
|
Corn, field
|
|
Potatoes
|
|
Tomato
|
|
STS soybean***
|
|
Cereals, Winter (wheat)
|
|
Cereals, Spring (wheat, oats, barley)
|
|
Corn (pop or sweet)
|
|
Cottonf
|
|
Cucumber
|
|
Flax
|
|
Soybeans
|
|
Snap beans, dry beans
|
|
Sunflower
|
|
Crops Not Listed
|
|
Anytime
|
|
4
|
|
4 •
|
|
4
|
|
4
|
|
9
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
10
|
|
18
|
|
fThe rotation interval should be extended to 18 months if droughtconditions prevail after application and before the rotational crop isplanted, unless sprinkler irrigation has been applied and totals greaterthan 15" during the growing season.
|
|
***Sulfonylurea Tolerant Soybean
|
|
SPRAYER PREPARATION/CLEANUP
|
|
It is important that spray equipment is clean and free of
|
|
previous pesticide deposits before using REQUIRE® Q (mp)
|
|
and then properly cleaned out following application. Clean all
|
|
application equipment before applying REQUIRE® Q (mp).
|
|
Follow the cleanup procedures specified on the label of the
|
|
product previously sprayed. If no cleanup procedure is
|
|
provided, use the procedure that follows. Immediately
|
|
following applications of REQUIRE® Q (mp), thoroughly
|
|
clean all mixing and spray equipment to avoid subsequent
|
|
crop injury.
|
|
Note:
|
|
• When cleaning spray equipment before applying
|
|
REQUIRE® Q (mp), read and follow label directions for
|
|
proper rinsate disposal of the product previously sprayed.
|
|
• A steam cleaning of aerial spray tanks is recommended to
|
|
dislodge any visible pesticide deposits.
|
|
• When spraying or mixing equipment will be used over an
|
|
extended period to apply multiple loads of REQUIRE® Q
|
|
(mp), partially fill the tank with fresh water at the end of each
|
|
day of spraying, flush the boom and hoses, and allow to sit
|
|
overnight.
|
|
Cleanup Procedure
|
|
1. Drain the tank and thoroughly hose down the interior
|
|
surfaces. Flush the tank, hoses, and boom with clean
|
|
water for a minimum of 5 min.
|
|
2. Partially fill the tank with clean water and add one gal of
|
|
household ammonia*** (containing 3% active) for every
|
|
100 gal of water. Finish filling the tank with water, then
|
|
flush the cleaning solution through the hoses, boom, and
|
|
nozzles. Add more water to completely fill the tank and
|
|
allow to agitate/recirculate for at least 15 min. Again,
|
|
flush the hoses, boom, and nozzles with the cleaning
|
|
solution, then drain the tank.
|
|
3. Repeat Step 2.
|
|
4. Remove the nozzles and screens and clean separately in a
|
|
bucket containing the cleaning agent and water.
|
|
|
|
5. Thoroughly rinse the tank with clean water for a
|
|
minimum of 5 min, flushing the water through the hoses
|
|
and boom.
|
|
""Equivalent amounts of an alternate strength ammonia solution or a tank
|
|
cleaner recommended in the DuPont bulletin "Sulfonylurea Herbicides, A
|
|
Guide to Equipment Cleanout," may be used.
|
|
SPRAY DRIFT MANAGEMENT
|
|
The interaction of many equipment and weather-related
|
|
factors determines the potential for spray drift. The
|
|
applicator is responsible for considering all these factors
|
|
when making application decisions.
|
|
AVOIDING SPRAY DRIFT IS THE RESPONSIBILITY
|
|
OF THE APPLICATOR.
|
|
IMPORTANCE OF DROPLET SIZE
|
|
The most effective way to reduce drift potential is to apply
|
|
large droplets (>150 - 200 microns). The best drift
|
|
management strategy is to apply the largest droplets that
|
|
provide sufficient coverage and control. The presence of
|
|
sensitive species nearby, the environmental conditions, and
|
|
pest pressure may affect how an applicator balances drift
|
|
control and coverage. APPLYING LARGER DROPLETS
|
|
REDUCES DRIFT POTENTIAL, BUT WILL NOT
|
|
PREVENT DRIFT IF APPLICATIONS ARE MADE
|
|
IMPROPERLY OR UNDER UNFAVORABLE
|
|
ENVIRONMENTAL CONDITIONS! See Wind,
|
|
Temperature and Humidity, and Temperature Inversions
|
|
sections of this label.
|
|
Controlling Droplet Size - General Techniques
|
|
• Volume - Use high flow rate nozzles to apply the highest
|
|
practical spray volume. Nozzles with higher rated flows
|
|
produce larger droplets.
|
|
• Pressure - Use the lower spray pressures recommended
|
|
for the nozzle. Higher pressure reduces droplet size and
|
|
does not improve canopy penetration. WHEN HIGHER
|
|
FLOW RATES ARE NEEDED, USE A HIGHER-
|
|
CAPACITY NOZZLE INSTEAD OF INCREASING
|
|
PRESSURE.
|
|
• Nozzle Type - Use a nozzle type that is designed for the
|
|
intended application. With most nozzle types, narrower
|
|
spray angles produce larger droplets. Consider using low-
|
|
drift nozzles.
|
|
BOOM HEIGHT
|
|
Set the boom at the lowest height that provides uniform
|
|
coverage and reduces the exposure of droplets to
|
|
evaporation and wind. For ground equipment, the boom
|
|
should remain level with the crop and have minimal bounce.
|
|
WIND
|
|
Drift potential increases at wind speeds of less than 3 mph
|
|
(due to inversion potential) or more than 10 mph. However,
|
|
many factors, including droplet size and equipment type
|
|
determine drift potential at any given wind speed. AVOID
|
|
APPLICATIONS DURING GUSTY OR WINDLESS
|
|
CONDITIONS.
|
|
Note: Local terrain can influence wind patterns. Every
|
|
applicator should be familiar with local wind patterns and
|
|
how they affect spray drift.
|
|
TEMPERATURE AND HUMIDITY
|
|
When making applications in hot and dry conditions, set up
|
|
equipment to produce larger droplets to reduce effects of
|
|
evaporation.
|
|
TEMPERATURE INVERSIONS
|
|
Drift potential is high during a temperature inversion.
|
|
Temperature inversions restrict vertical air mixing, which
|
|
causes small suspended droplets to remain close to the
|
|
ground and move laterally in a concentrated cloud.
|
|
Temperature inversions are characterized by increasing
|
|
temperature with altitude and are common on nights with
|
|
limited cloud cover and light to no wind. They begin to form
|
|
as the sun sets and often continue into the morning. Their
|
|
presence can be indicated by ground fog; however, if fog is
|
|
not present, inversions can also be identified by the movement
|
|
of smoke from a ground source or an aircraft smoke
|
|
generator. Smoke that layers and moves laterally in a
|
|
concentrated cloud (under low wind conditions) indicates an
|
|
inversion, while smoke that moves upward and rapidly
|
|
dissipates indicates good vertical air mixing.
|
|
SHIELDED SPRAYERS
|
|
Shielding the boom or individual nozzles can reduce the
|
|
effects of wind. However, it is the responsibility of the
|
|
applicator to verify that the shields are preventing drift and
|
|
not interfering with uniform deposition of the product.
|
|
AIR-ASSISTED (AIR BLAST)
|
|
FIELD CROP SPRAYERS
|
|
Air-assisted field crop sprayers carry droplets to the target via
|
|
a downward-directed airstream. Some may reduce the
|
|
potential for drift, but if a sprayer is unsuitable for the
|
|
application and/or set up improperly, high drift potential can
|
|
result. It is the responsibility of the applicator to determine
|
|
that a sprayer is suitable for the intended application and is
|
|
configured properly, and that drift is not occurring.
|
|
INTEGRATED PEST MANAGEMENT
|
|
This product may be used as part of an Integrated Pest
|
|
Management (IPM) program that can include biological,
|
|
cultural, and genetic practices aimed at preventing
|
|
economic pest damage. IPM principles and practices
|
|
include field scouting or other detection methods, correct
|
|
target pest identification, population monitoring, and
|
|
treating when target pest populations reach locally
|
|
determined action thresholds. Consult your state cooperative
|
|
extension service, professional consultants or other qualified
|
|
authorities to determine appropriate action treatment
|
|
threshold levels for treating specific pest/crop systems in
|
|
your area.
|
|
RESISTANCE
|
|
When herbicides that affect the same biological site of
|
|
action are used repeatedly over several years to control the
|
|
same weed species in the same field, naturally-occurring
|
|
resistant biotypes may survive a correctly applied herbicide
|
|
treatment, propagate, and become dominant in that field.
|
|
Adequate control of these resistant weed biotypes cannot be
|
|
expected. If weed control is unsatisfactory, it may be
|
|
necessary to retreat the problem area using a product
|
|
affecting a different site of action.
|
|
8
|
|
|
|
To better manage herbicide resistance through delaying the
|
|
proliferation and possible dominance of herbicide resistant
|
|
weed biotypes, it may be necessary to change cultural
|
|
practices within and between crop seasons such as using a
|
|
combination of tillage, retreatment, tank-mix partners
|
|
and/or sequential herbicide applications that have a different
|
|
site of action. Weed escapes that are allowed to go to seed
|
|
will promote the spread of resistant biotypes.
|
|
It is advisable to keep accurate records of pesticides applied
|
|
to individual fields to help obtain information on the spread
|
|
and dispersal of resistant biotypes. Consult your
|
|
agricultural dealer, consultant, applicator, and/or
|
|
appropriate state agricultural extension service
|
|
representative for specific alternative cultural practices or
|
|
herbicide recommendations available in your area.
|
|
SOIL INSECTICIDE
|
|
INTERACTION INFORMATION
|
|
DuPont™ REQUIRE® Q (mp) may interact with certain
|
|
insecticides previously applied to the crop. Crop response
|
|
varies with field corn type, insecticide used, insecticide
|
|
application method, and soil type.
|
|
REQUIRE® Q (mp) may be applied to corn previously
|
|
treated with "Fortress", "Aztec", or "Force" insecticides or
|
|
nonorganophosphate (OP) soil insecticides regardless of soil
|
|
type.
|
|
•Do not apply REQUIRE® Q (mp) within 60 days of crop
|
|
emergence where an organophosphate insecticide (such as
|
|
Counter) was applied as an in-furrow treatment since crop
|
|
injury may occur. Also, allow at least 60 days between a pre-
|
|
plant application of REQUIRE® Q (mp) and application of
|
|
an organophosphate insecticide since crop injury may result.
|
|
•DO NOT APPLY REQUIRE® Q (mp) to corn previously
|
|
treated with "Counter" 15G or to corn treated with
|
|
"Counter" 20CR infurrow or over the row at cultivation.
|
|
- Applications of REQUIRE® Q (mp) to corn previously
|
|
treated with "Counter" 20 CR, "Lorsban", or "Thimet" may
|
|
cause unacceptable crop injury, especially on soils of less
|
|
than 4% organic matter.
|
|
PRECAUTIONS
|
|
REQUIRE® Q (mp) may cause injury to desirable trees and
|
|
plants, particularly beans, cotton, flowers, fruit trees, grapes,
|
|
ornamentals, peas, potatoes, soybeans, sunflowers, tobacco,
|
|
tomatoes, and other broadleaf plants when contacting their
|
|
roots stems or foliage. These plants are most sensitive to
|
|
REQUIRE® Q (mp) during their development or growing
|
|
stage.
|
|
Injury or loss of desirable trees or vegetation may result from
|
|
failure to observe the following:
|
|
- Do not apply REQUIRE® Q (mp) or drain or flush
|
|
application equipment on or near desirable trees or other
|
|
plants, or on areas where their roots may extend, or in
|
|
locations where the chemical may be washed or moved into
|
|
contact with their roots.
|
|
- Do not use on lawns, walks, driveways, tennis courts, or
|
|
similar areas.
|
|
- Prevent drift or spray to desirable plants.
|
|
- Do not contaminate any body of water.
|
|
- Thoroughly clean application equipment immediately after
|
|
use. (See Sprayer Cleanup section of this label for
|
|
instructions).
|
|
Crop injury may occur following an application of
|
|
REQUIRE® Q (mp) if there is a prolonged period of cold
|
|
weather and/or in conjunction with wet soils.
|
|
A corn plant's predisposition to develop fused tissue
|
|
merging from the whorl (rattail) after the V-l 1 stage may
|
|
increase when a product containing dicamba or other
|
|
growth regulator herbicides [e.g. REQUIRE® Q (mp)] is
|
|
applied to small corn (less than 4 inches in height) under
|
|
early stressful conditions. See ENVIRONMENTAL
|
|
CONDITIONS for a description of these stressful
|
|
conditions.
|
|
Corn may be harvested or grazed for feed once the crop has
|
|
reached the ensilage (milk) stage or later in maturity.
|
|
However, do not graze, feed forage, grain or fodder (stover)
|
|
from treated areas to livestock within 30 days of REQUIRE®
|
|
Q (mp) application.
|
|
|
|
STORAGE AND DISPOSAL
|
|
Do not contaminate water, food, or feed by storage and
|
|
disposal.
|
|
Pesticide Storage: Store product in original container
|
|
only. Store in a cool, dry place.
|
|
Pesticide Disposal: Waste resulting from the use of
|
|
this product must be disposed of on site or at an
|
|
approved waste disposal facility.
|
|
Container Handling: Refer to the Net Contents
|
|
section of this product's labeling for the applicable
|
|
"Nonrefillable Container" or "Refillable
|
|
Container" designation.
|
|
Nonrefillable Plastic and Metal Containers
|
|
(Capacity Equal to or Less Than 50 Pounds):
|
|
Nonrefillable container. Do not reuse or refill this
|
|
container. Triple rinse container (or equivalent)
|
|
promptly after emptying. Triple rinse as follows:
|
|
Empty the remaining contents into application
|
|
equipment or a mix tank. Fill the container 1/4 full
|
|
with water and recap. Shake for 10 seconds. Pour
|
|
rinsate into application equipment or a mix tank or
|
|
store rinsate for later use or disposal. Drain for 10
|
|
seconds after the flow begins to drip. Repeat this
|
|
procedure two more times. Then, for Plastic
|
|
Containers, offer for recycling if available or puncture
|
|
and dispose of in a sanitary landfill, or by incineration.
|
|
Do not burn, unless allowed by state and local
|
|
ordinances. For Metal Containers, offer for recycling if
|
|
available or reconditioning if appropriate, or puncture
|
|
and dispose of in a sanitary landfill, or by other
|
|
procedures approved by state and local authorities
|
|
Nonrefillable Plastic and Metal Containers
|
|
(Capacity Greater Than 50 Pounds): Nonrefillable
|
|
container. Do not reuse or refill this container. Triple
|
|
rinse container (or equivalent) promptly after
|
|
emptying: Triple rinse as follows: Empty the remaining
|
|
contents into application equipment or a mix tank. Fill
|
|
the container 1/4 full with water. Replace and tighten
|
|
closures. Tip container on its side and roll it back and
|
|
forth, ensuring at least one complete revolution, for 30
|
|
seconds. Stand the container on its end and tip it back
|
|
and forth several times. Turn the container over onto its
|
|
other end and tip it back and forth several times. Empty
|
|
the rinsate into application equipment or a mix tank or
|
|
store rinsate for later use or disposal. Repeat this
|
|
procedure two more times. Then, for Plastic
|
|
Containers, offer for recycling if available or puncture
|
|
and dispose of in a sanitary landfill, or by incineration.
|
|
Do not burn, unless allowed by state and local
|
|
ordinances. For Metal Containers, offer for recycling if
|
|
available or reconditioning if appropriate, or puncture
|
|
and dispose of in a sanitary landfill, or by other
|
|
procedures approved by state and local authorities.
|
|
Nonrefillable Plastic and Metal Containers, e.g.,
|
|
Intermediate Bulk Containers [IBC] (Size or Shape
|
|
Too Large to be Tipped, Rolled or Turned Upside
|
|
Down): Nonrefillable container. Do not reuse or refill
|
|
this container. Clean container promptly after emptying
|
|
the contents from this container into application
|
|
equipment or mix tank and before final disposal using
|
|
the following pressure rinsing procedure. Insert a lance
|
|
fitted with a suitable tank cleaning nozzle into the
|
|
container and ensure that the water spray thoroughly
|
|
covers the top, bottom and all sides inside the
|
|
container. The nozzle manufacturer generally provides
|
|
instructions for the appropriate spray pressure, spray
|
|
duration and/or spray volume. If the manufacturer's
|
|
instructions are not available, pressure rinse the
|
|
container for at least 60 seconds using a minimum
|
|
pressure of 30 PSI with a minimum rinse volume of
|
|
10% of the container volume. Drain, pour or pump
|
|
rinsate into application equipment or rinsate collection
|
|
system. Repeat this pressure rinsing procedure two
|
|
more times. Then, for Plastic Containers, offer for
|
|
recycling if available or puncture and dispose of in a
|
|
sanitary landfill, or by incineration. For Metal
|
|
Containers, offer for recycling if available or
|
|
reconditioning if appropriate, or puncture and dispose
|
|
of in a sanitary landfill, or by other procedures
|
|
approved by state and local authorities.
|
|
Nonrefillable Paper or Plastic Bags, Fiber Sacks
|
|
including Flexible Intermediate Bulk Containers
|
|
(FIBC) or Fiber Drums With Liners: Nonrefillable
|
|
container. Do not reuse or refill this container.
|
|
Completely empty paper or plastic bag, fiber sack or
|
|
drum liner by shaking and tapping sides and bottom to
|
|
loosen clinging particles. Empty residue into
|
|
application or manufacturing equipment. Then offer for
|
|
recycling if available or dispose of empty paper or
|
|
plastic bag, fiber sack or fiber drum and liner in a
|
|
sanitary landfill, or by incineration. Do not burn, unless
|
|
allowed by state and local ordinances. Refillable Fiber
|
|
Drums With Liners: Refillable container (fiber drum
|
|
only). Refilling Fiber Drum: Refill this fiber drum with
|
|
DuPont™ REQUIRE® Q (mp) Herbicide containing
|
|
rimsulfuron and dicamba only. Do not reuse this fiber
|
|
drum for any other purpose. Cleaning before refilling is
|
|
the responsibility of the refiller. Completely empty
|
|
liner by shaking and tapping sides and bottom to
|
|
loosen clinging particles. Empty residue into
|
|
application or manufacturing equipment. Disposing of
|
|
Fiber Drum and/or Liner: Do not reuse this fiber drum
|
|
for any other purpose other than refilling (see
|
|
preceding). Cleaning the container (liner and/or fiber
|
|
drum) before final disposal is the responsibility of the
|
|
person disposing of the container. Offer the liner for
|
|
recycling if available or dispose of liner in a sanitary
|
|
landfill, or by incineration. Do not burn, unless allowed
|
|
by state and local ordinances. If drum is contaminated
|
|
and cannot be reused, dispose of it in the manner
|
|
required for its liner. To clean the fiber drum before
|
|
final disposal, completely empty the fiber drum by
|
|
shaking and tapping sides and bottom to loosen
|
|
clinging particles. Empty residue into application or
|
|
manufacturing equipment. Then offer the fiber drum
|
|
for recycling if available or dispose of in a sanitary
|
|
landfill, or by incineration. Do not burn, unless allowed
|
|
by state and local ordinances.
|
|
10
|
|
|
|
All Other Refillable Containers: Refillable container.
|
|
Refilling Container: Refill this container with
|
|
DuPont™ REQUIRE® Q (mp) containing rimsulfuron
|
|
and dicamba only. Do not reuse this container for any
|
|
other purpose. Cleaning before refilling is the
|
|
responsibility of the refiller. Prior to refilling, inspect
|
|
carefully for damage such as cracks, punctures,
|
|
abrasions, worn out threads and closure devices. If
|
|
damage is found, do not use the container, contact
|
|
DuPont at the number below for instructions. Check for
|
|
leaks after refilling and before transporting. If leaks are
|
|
found, do not reuse or transport container, contact
|
|
DuPont at the number below for instructions.
|
|
Disposing of Container: Do not reuse this container for
|
|
any other purpose other than refilling (see preceding).
|
|
Cleaning the container before final disposal is the
|
|
responsibility of the person disposing of the container.
|
|
To clean the container before final disposal, use the
|
|
following pressure rinsing procedure. Insert a lance
|
|
fitted with a suitable tank cleaning nozzle into the
|
|
container and ensure that the water spray thoroughly
|
|
covers the top, bottom and all sides inside the
|
|
container. The nozzle manufacturer generally provides
|
|
instructions for the appropriate spray pressure, spray
|
|
duration and/or spray volume. If the manufacturer's
|
|
instructions are not available, pressure rinse the
|
|
container for at least 60 seconds using a minimum
|
|
pressure of 30 PSI with a minimum rinse volume of
|
|
10% of the container volume. Drain, pour or pump
|
|
rinsate into application equipment or rinsate collection
|
|
system. Repeat this pressure rinsing procedure two
|
|
more times. Then, for Plastic Containers, offer for
|
|
recycling if available or puncture and dispose of in a
|
|
sanitary landfill, or by incineration. Do not burn, unless
|
|
allowed by state and local ordinances. For Metal
|
|
Containers, offer for recycling if available or
|
|
reconditioning if appropriate, or puncture and dispose
|
|
of in a sanitary landfill, or by other procedures
|
|
approved by state and local authorities.
|
|
Outer Foil Pouches of Water Soluble Packets
|
|
(WSP): Nonrefillable container. Do not reuse or refill
|
|
this container. Offer for recycling if available or,
|
|
dispose of the empty outer foil pouch in the trash as
|
|
long as WSP is unbroken. If the outer pouch contacts
|
|
the formulated product in any way, the pouch must be
|
|
triple rinsed with clean water. Add the rinsate to the
|
|
spray tank and dispose of the outer pouch as described
|
|
previously.
|
|
Do not transport if this container is damaged or
|
|
leaking. If the container is damaged, leaking or
|
|
obsolete, or in the event of a major spill, fire or other
|
|
emergency, contact DuPont at 1-800-441-3637, day or
|
|
night.
|
|
NOTICE TO BUYER: Purchase of this material does not
|
|
confer any rights under patents of countries outside of the
|
|
United States.
|
|
This product includes ingredients that are covered under one
|
|
or more of the following Bayer CropScience patents:
|
|
6,486,096; 6,569,805; 5,922,646; and 5,516,750.
|
|
Purchase of this product includes a license for use only as
|
|
specified on this label. Any use, mixture or formulation of
|
|
this product other than as described on this label is
|
|
expressly not authorized.
|
|
The DuPont Oval Logo, DuPont™, REQUIRE®,
|
|
ACCENT®, BASIS®, BREAKFREE®, RESOLVE®,
|
|
STEADFAST® and CINCH® are trademarks or registered
|
|
trademarks of E. I. duPont de Nemours and Company
|
|
"Harness", "Roundup Ready", "Roundup Original", "Roundup
|
|
Weathermax" are registered trademarks of Monsanto Technology
|
|
LLC
|
|
"Aztec", "Balance" and "Liberty" are registered trademarks of
|
|
Bayer Crop Science
|
|
"Banvel", "Clarity", "Marksman", "Basagran", "Laddok" and
|
|
"Outlook" are registered trademarks of BASF Corporation
|
|
"Force", "Lumax" and "Lexar" are registered trademarks of
|
|
Syngenta Group company
|
|
"Counter", "Thimet", "Fortress" and "Impact" are registered
|
|
trademarks of Amvac Chemical Corporation
|
|
"Lorsban" and "Starane" are registered trademarks of DowAgro
|
|
Sciences LLC
|
|
D-1701 071911
|
|
11
|
|
|
|
LIMITATION OF
|
|
WARRANTY AND LIABILITY
|
|
NOTICE: Read this Limitation of Warranty and
|
|
Liability Before Buying or Using This Product. If the
|
|
Terms Are Not Acceptable, Return the Product at Once,
|
|
Unopened, and the Purchase Price Will Be Refunded.
|
|
It is impossible to eliminate all risks associated with the
|
|
use of this product. Such risks arise from weather
|
|
conditions, soil factors, off target movement,
|
|
unconventional farming techniques, presence of other
|
|
materials, the manner of use or application, or other
|
|
unknown factors, all of which are beyond the control of
|
|
DuPont. These risks can cause: ineffectiveness of the
|
|
product, crop injury, or injury to non-target crops or
|
|
plants. WHEN YOU BUY OR USE THIS PRODUCT,
|
|
YOU AGREE TO ACCEPT THESE RISKS.
|
|
DuPont warrants that this product conforms to the
|
|
chemical description on the label thereof and is
|
|
reasonably fit for the purpose stated in the Directions for
|
|
Use, subject to the inherent risks described above, when
|
|
used in accordance with the Directions for Use under
|
|
normal conditions.
|
|
TO THE EXTENT CONSISTENT WITH
|
|
APPLICABLE LAW, DUPONT MAKES NO OTHER
|
|
EXPRESS OR IMPLIED WARRANTY OF FITNESS
|
|
OR OF MERCHANTABILITY OR ANY OTHER
|
|
EXPRESS OR IMPLIED WARRANTY. TO THE
|
|
EXTENT CONSISTENT WITH APPLICABLE LAW,
|
|
IN NO EVENT SHALL DUPONT OR SELLER BE
|
|
LIABLE FOR ANY INCIDENTAL,
|
|
CONSEQUENTIAL OR SPECIAL DAMAGES
|
|
RESULTING FROM THE USE OR. HANDLING OF
|
|
THIS PRODUCT. BUYER'S OR USER'S
|
|
BARGAINED-FOR EXPECTATION IS CROP
|
|
PROTECTION. TO THE EXTENT CONSISTENT
|
|
WITH APPLICABLE LAW, THE EXCLUSIVE
|
|
REMEDY OF THE USER OR BUYER AND THE
|
|
EXCLUSIVE LIABILITY OF DUPONT OR SELLER,
|
|
FOR ANY AND ALL CLAIMS, LOSSES, INJURIES
|
|
OR DAMAGES (INCLUDING CLAIMS BASED ON
|
|
BREACH OF WARRANTY OR CONTRACT,
|
|
NEGLIGENCE, TORT OR STRICT LIABILITY),
|
|
WHETHER FROM FAILURE TO PERFORM OR
|
|
INJURY TO CROPS OR OTHER PLANTS, AND
|
|
RESULTING FROM THE USE OR HANDLING OF
|
|
THIS PRODUCT, SHALL BE THE RETURN OF THE
|
|
PURCHASE PRICE OF THE PRODUCT, OR AT THE
|
|
ELECTION OF DUPONT OR SELLER, THE
|
|
REPLACEMENT OF THE PRODUCT.
|
|
To the extent consistent with applicable law that allows
|
|
such requirement, DuPont or its Ag Retailer must have
|
|
prompt notice of any claim so that an immediate
|
|
inspection of buyer's or user's growing crops can be
|
|
made. Buyer and all users shall promptly notify DuPont
|
|
or a DuPont Ag Retailer of any claims, whether based
|
|
on contract, negligence, strict liability, other tort or
|
|
otherwise, or be barred from any remedy.
|
|
This Limitation of Warranty and Liability may not be
|
|
amended by any oral or written agreement.
|
|
For product information call: 1-888-6-DUPONT [1-888-638-7668]
|
|
Internet address: http://cropprotection.dupont.com/
|
|
© 2008-2011 E. L du Pont de Nemours and Company, Crop Protection, 1007 Market Street, Wilmington, Delaware 19898.
|
|
All rights reserved.
|
|
12
|