927 lines
52 KiB
Markdown
927 lines
52 KiB
Markdown
# USF0115
|
||
|
||
- EPA Reg No: **264-1209**
|
||
- Registrant: BAYER CROPSCIENCE, LLC
|
||
- Signal word: Caution
|
||
- Active ingredients: Fluopyram (8.7%); Prothioconazole (17.39%); Tebuconazole (8.7%)
|
||
- Label accepted: 2026-08-22
|
||
- Source PDF: https://www3.epa.gov/pesticides/chem_search/ppls/000264-01209-20260822.pdf
|
||
|
||
---
|
||
1
|
||
|
||
|
||
August 22, 2026
|
||
|
||
Daljit Singh
|
||
Senior Regulatory Affairs Manager
|
||
Bayer CropScience LP
|
||
800 N. Lindbergh Blvd.
|
||
St. Louis, MO 63167
|
||
|
||
Subject: Label Amendment – Updating application instructions, mixing instructions
|
||
Registration Review Label Amendment – Incorporating Mitigation Measures
|
||
from the Registration Review Interim Decision for Prothioconazole
|
||
Product Name: USF0115
|
||
EPA Registration Number: 264-1209
|
||
Application Date(s): 12/27/2021, 6/28/2022
|
||
Case Number/Decision Number: 476899, 475383
|
||
|
||
Dear Daljit Singh:
|
||
|
||
The amended label referred to above, submitted in connection with registration under the
|
||
Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), as amended, is acceptable. This
|
||
approval does not affect any conditions that were previously imposed on this registration. You
|
||
continue to be subject to existing conditions on your registration and any deadlines connected
|
||
with them.
|
||
|
||
The Agency, in accordance with FIFRA, as amended, has completed reviewing all the
|
||
information submitted with your application to support the Registration Review of the above
|
||
referenced product in connection with the Prothioconazole Interim Decision. The Agency has
|
||
concluded that your submission is acceptable.
|
||
|
||
A stamped copy of your labeling is enclosed for your records. This labeling supersedes all
|
||
previously accepted labeling. The next label printing of this product must use this labeling unless
|
||
subsequent changes have been approved. You must submit one copy of the final printed
|
||
labeling before you release the product for shipment with the new labeling. In accordance with
|
||
40 CFR 152.130(c), you may distribute or sell this product under the previously approved
|
||
labeling for 12 months from the date of this letter. After 12 months, you may only distribute or
|
||
sell this product if it bears this new revised labeling or subsequently approved labeling.
|
||
“To distribute or sell” is defined under FIFRA section 2(gg) and its implementing regulation at 40
|
||
CFR 152.3.
|
||
|
||
Page 2 of 2
|
||
EPA Reg. No. 264-1209
|
||
Case No./Decision No. 476899, 475383
|
||
|
||
|
||
Should you wish to add/retain a reference to the company’s website on your label, then please
|
||
be aware that the website becomes labeling under FIFRA and is subject to review by the
|
||
Agency. If the website is false or misleading, the product would be misbranded and unlawful to
|
||
sell or distribute under FIFRA section 12(a)(1)(E). 40 CFR 156.10(a)(5) lists examples of
|
||
statements EPA may consider false or misleading. In addition, regardless of whether a website
|
||
is referenced on your product’s label, claims made on the website may not substantially differ
|
||
from those claims approved through the registration process. Therefore, should the Agency find
|
||
or if it is brought to our attention that a website contains false or misleading statements or
|
||
claims substantially differing from the EPA approved registration, the website will be referred
|
||
to the EPA’s Office of Enforcement and Compliance.
|
||
|
||
Your release for shipment of the product constitutes acceptance of these conditions. If these
|
||
conditions are not complied with, the registration will be subject to cancellation in accordance
|
||
with FIFRA section 6.
|
||
|
||
If you have any questions, please contact James Orrock by phone at 202-566-2862 or by email
|
||
at orrock.james@epa.gov.
|
||
|
||
Sincerely,
|
||
|
||
|
||
|
||
|
||
|
||
|
||
James Orrock, Plant Pathologist
|
||
Product Team 22, Fungicide Branch
|
||
Registration Division (7505T)
|
||
|
||
|
||
Enclosure
|
||
|
||
1
|
||
|
||
|
||
PROTHIOCONAZOLE GROUP 3 FUNGICIDE
|
||
TEBUCONAZOLE GROUP 3 FUNGICIDE
|
||
FLUOPYRAM GROUP 7 FUNGICIDE
|
||
USF0115
|
||
[ABN: Prosaro PRO 400 SC Fungicide]
|
||
|
||
For control of specific diseases on listed crops.
|
||
|
||
|
||
Active Ingredients:
|
||
Prothioconazole, 2-[2-(1-Chlorocyclopropyl)-3-(2-chlorophenyl)-2-hydroxypropyl]-1,2-dihydro-3H-1,2,4-triazole-3-
|
||
thione……………………………………………………………………………………………………………………...17.39%
|
||
Tebuconazole, alpha-[2-(4-chlorophenyl)ethyl]-alpha-(1,1-dimethylethyl)-1H-1,2,4-triazole-1-ethanol…………8.70%
|
||
Fluopyram, N-[2-[3-chloro-5-(trifluoromethyl)-2-pyridinyl]ethyl]-2 (trifluoromethyl)benzamide…………………...8.70%
|
||
Other Ingredients: ..............................................................................................................................................65.21%
|
||
TOTAL: 100.0%
|
||
Contains 1.67 pounds of prothioconazole, 0.84 pounds of tebuconazole, and 0.84 pounds of fluopyram per U.S. gallon
|
||
EPA Reg. No. 264-1209 EPA Est.
|
||
|
||
KEEP OUT OF REACH OF CHILDREN
|
||
CAUTION
|
||
For MEDICAL and TRANSPORTATION Emergencies ONLY Call 24 Hours A Day 1-800-
|
||
334-7577 For PRODUCT USE Information Call 1-866-99BAYER (1-866-992-2937)
|
||
|
||
See [Back][Side] Panel for First Aid Instructions and [Leaflet][Booklet] for Complete Precautionary
|
||
Statements and Directions for Use. (Note to reviewer: Location of additional precautionary statements,
|
||
directions for use will vary between those listed, depending on container type/size.)
|
||
|
||
Net Contents:
|
||
|
||
|
||
|
||
|
||
PRODUCED FOR
|
||
|
||
Bayer CropScience LLC
|
||
800 N. Lindbergh Blvd.
|
||
St. Louis, MO 63167
|
||
1-866-99BAYER (1-866-992-2937)
|
||
Aug 22, 2026
|
||
264-1209
|
||
|
||
2
|
||
|
||
|
||
FIRST AID
|
||
IF SWALLOWED: • Call a poison control center or doctor immediately for treatment advice.
|
||
• Do not induce vomiting unless told to do so by a poison control center or doctor.
|
||
• Have person sip a glass of water if able to swallow.
|
||
• Do not give anything by mouth to an unconscious person.
|
||
IF ON SKIN OR
|
||
CLOTHING:
|
||
• Take off contaminated clothing.
|
||
• Rinse skin immediately with plenty of water for 15-20 minutes.
|
||
• Call a poison control center or doctor for treatment advice.
|
||
IF IN EYES: • Hold eye open and rinse slowly and gently with water for 15-20 minutes.
|
||
• Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye.
|
||
• Call a poison control center or doctor for treatment advice.
|
||
IF INHALED: • Move person to fresh air.
|
||
• If person is not breathing, call 911 or an ambulance, and then give artificial respiration, preferably
|
||
mouth-to-mouth if possible.
|
||
• Call a poison control center or doctor for treatment advice.
|
||
For MEDICAL Emergencies Call 24 Hours A Day 1-800-334-7577.
|
||
Have the product container or label with you when calling a poison control center or doctor or going for treatment.
|
||
NOTE TO PHYSICIAN: No specific antidote. Treat symptomatically.
|
||
|
||
PRECAUTIONARY STATEMENTS
|
||
HAZARDS TO HUMANS AND DOMESTIC
|
||
ANIMALS CAUTION
|
||
Harmful if swallowed, inhaled, or absorbed through the skin. Causes moderate eye irritation. Avoid contact with skin, eyes, a nd
|
||
clothing. Avoid breathing vapor or spray mist. Wash thoroughly with soap and water after handling and before eating, drinking ,
|
||
chewing gum, or using tobacco, or using the toilet. Remove and wash contaminated clothing before reuse.
|
||
|
||
Personal Protective Equipment (PPE)
|
||
Applicators and other handlers must wear:
|
||
• Long-sleeved shirt and long pants
|
||
• Chemical resistant gloves made of any waterproof material
|
||
• Shoes plus socks
|
||
• protective eyewear
|
||
Engineering Control Statements
|
||
When handlers use closed systems, enclosed cabs, or aircraft in a manner that meets the requirements listed in the Worker
|
||
Protection Standard (WPS) for agricultural pesticides [40 CFR 170.607 (d)(e)(f)], the handler PPE requirements may be reduced
|
||
or modified as specified in the WPS.
|
||
|
||
USER SAFETY RECOMMENDATIONS
|
||
• Users should remove clothing/PPE immediately if pesticide gets inside. Then wash thoroughly and put on clean clothing.
|
||
• Users should remove PPE immediately after handling this product. Wash the outside of gloves before removing. As soon as
|
||
possible, wash thoroughly and change into clean clothing.
|
||
|
||
USER SAFETY REQUIREMENTS
|
||
Follow manufacturer's instructions for cleaning/maintaining PPE. If no such instructions for washables exist, use detergent and hot
|
||
water. Keep and wash PPE separately from other laundry.
|
||
|
||
3
|
||
|
||
|
||
ENVIRONMENTAL HAZARDS
|
||
This product is toxic to mammals, fish, aquatic invertebrates, and freshwater/estuarine/marine aquatic plants. Do not apply directly
|
||
to water, or to areas where surface water is present or to intertidal areas below the mean high water mark. Runoff may be
|
||
hazardous to aquatic organisms in neighboring areas. Do not contaminate water when disposing of equipment washwater or
|
||
rinsate.
|
||
|
||
Surface Water Advisory
|
||
This product may impact surface water quality due to runoff of rain water. This is especially true for poorly draining soils and soils
|
||
with shallow ground water. This product is classified as having high potential for reaching surface water via runoff for several
|
||
months or more after application. A level, well-maintained vegetative buffer strip between areas to which this product is applied
|
||
and surface water features such as ponds, streams, and springs will reduce the potential loading of this product from runoff water
|
||
and sediment. Runoff of this product will be reduced by avoiding applications when rainfall or irrigation is expected to occur within
|
||
48 hours.
|
||
|
||
Ground Water Advisory
|
||
Degradates of prothioconazole are known to leach through soil into groundwater under certain conditions as a result of label use.
|
||
These chemicals may leach into groundwater if used in areas where soils are permeable, particularly where the water table is
|
||
shallow.
|
||
|
||
CONDITIONS OF SALE AND LIMITATIONS OF WARRANTY AND LIABILITY
|
||
Read the entire Directions for Use, Conditions, Disclaimer of Warranties and Limitations of Liability before using this product. If terms
|
||
are not acceptable, return the unopened product container at once.
|
||
By using this product, user or buyer accepts the following Conditions, Disclaimer of Warranties and Limitations of Liability.
|
||
CONDITIONS: The directions for use of this product are believed to be adequate and must be followed carefully. However, it is
|
||
impossible to eliminate all risks associated with the use of this product. Crop injury, ineffectiveness or other unintended consequences
|
||
may result because of such factors as weather conditions, presence of other materials, or the manner of use or application, all of which
|
||
are beyond the control of Bayer CropScience. To the extent consistent with applicable law, all such risks shall be assumed by the user
|
||
or buyer.
|
||
DISCLAIMER OF WARRANTIES: TO THE EXTENT CONSISTENT WITH APPLICABLE LAW, BAYER CROPSCIENCE
|
||
MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR
|
||
PURPOSE OR OTHERWISE, THAT EXTEND BEYOND THE STATEMENTS MADE ON THIS LABEL. No agent of Bayer CropScience
|
||
is authorized to make any warranties beyond those contained herein or to modify the warranties contained herein. TO THE EXTENT
|
||
CONSISTENT WITH APPLICABLE LAW, BAYER CROPSCIENCE DISCLAIMS ANY LIABILITY WHATSOEVER FOR SPECIAL,
|
||
INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT.
|
||
LIMITATIONS OF LIABILITY: TO THE EXTENT CONSISTENT WITH APPLICABLE LAW, THE EXCLUSIVE REMEDY OF THE
|
||
USER OR BUYER FOR ANY AND ALL LOSSES, INJURIES OR DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS
|
||
PRODUCT, WHETHER IN CONTRACT, WARRANTY, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE, SHALL NOT
|
||
EXCEED THE PURCHASE PRICE PAID, OR AT BAYER CROPSCIENCE’S ELECTION, THE REPLACEMENT OF PRODUCT.
|
||
|
||
4
|
||
|
||
|
||
DIRECTIONS FOR USE
|
||
It is a violation of federal law to use this product in a manner inconsistent with its labeling.
|
||
Do not apply this product in a way that will contact workers or other persons, either directly or through drift. Only protected
|
||
handlers may be in the area during application. For any requirements specific to your State or Tribe, consult the agency
|
||
responsible for pesticide regulation.
|
||
DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized hand equipment.
|
||
Not for sale, distribution, or use in Nassau and Suffolk counties, New York [except as permitted under FIFRA 24(c),
|
||
Special Local Need registration.]
|
||
AGRICULTURAL USE REQUIREMENTS
|
||
Use this product only in accordance with its labeling and with the Worker Protection Standard, 40 CFR part 170. This Standard
|
||
contains requirements for the protection of agricultural workers on farms, forests, nurseries, and greenhouses, and handlers of
|
||
agricultural pesticides. It contains requirements for training, decontamination, notification, and emergency assistance. It als o
|
||
contains specific instructions and exceptions pertaining to the statements on this label about personal protective equipment (PPE)
|
||
and restricted-entry interval (REI). The requirements in this box only apply to uses of this product that are covered by the Worker
|
||
Protection Standard.
|
||
Do not enter or allow worker entry into treated areas during the REI of 12 hours. Some crops have longer crop-specific REIs. Crop
|
||
specific REIs are listed in the Directions for Use section associated with the crop.
|
||
PPE required for early entry to treated areas that is permitted under the Worker Protection Standard and that involves contact with
|
||
anything that has been treated, such as plants, soil, or water is:
|
||
• coveralls over long-sleeved shirt and long pants
|
||
• chemical-resistant gloves made of any waterproof material
|
||
• chemical-resistant footwear plus socks
|
||
• protective eyewear
|
||
|
||
PRODUCT INFORMATION
|
||
• USF0115 is a broad -spectrum systemic fungicide for the control of Ascomycetes, Basidiomycetes and Deuteromycetes
|
||
diseases in barley, corn (field corn, field corn grown for seed, popcorn, and sweet corn), peanut, and wheat. Under
|
||
conditions conducive to extended infection periods or high disease pressure, another registered fungicide may be needed
|
||
once this product’s maximum application rates have been reached. Under these conditions use another fungicide
|
||
registered for the crop/disease.
|
||
|
||
USE RESTRICTIONS
|
||
• Observe the following restrictions when spraying in the vicinity of aquatic areas such as lakes, reservoirs, rivers,
|
||
permanent streams, marshes or natural ponds, and estuaries.
|
||
o Apply only during alternate years in fields adjacent to aquatic areas listed above.
|
||
o Do not apply by ground or air within 100 feet of aquatic areas listed above.
|
||
o Do not cultivate within 10 feet of an aquatic area to allow growth of a vegetative filter strip.
|
||
o Spray Drift Management: For aerial applications, the spray boom should be mounted on the aircraft so as to
|
||
minimize drift caused by wing tip vortices. The minimum practical boom length should be used, and must not
|
||
exceed 75% of the wingspan or rotor diameter.
|
||
o Use the largest droplet size consistent with pest control. Formation of very small droplets may be minimized by
|
||
appropriate nozzle selection, by orienting nozzles away from the air stream as much as possible and by avoiding
|
||
excessive spray boom pressure.
|
||
o Apply in a minimum of 2 gallons of spray solution by acre by aircraft spray equipment, unless stated differently in
|
||
the CROP USE DIRECTIONS.
|
||
o Spray should be released at the lowest possible height consistent with good pest control and flight safety.
|
||
Applications more than 10 feet above the crop canopy should be avoided.
|
||
o Make aerial or ground applications when wind velocity favors on-target product deposition (approximately 3 to 10
|
||
mph). Do not apply when wind velocity exceeds 15 mph. Avoid applications when wind gusts approach 15 mph.
|
||
o Risk of exposure to sensitive aquatic areas can be reduced by avoiding applications when wind direction is toward
|
||
the aquatic area.
|
||
o Low humidity and high temperatures increase the evaporation rate of spray droplets and therefore the likelihood
|
||
of spray drift to aquatic areas. Avoid spraying during conditions of low humidity and/or high temperature.
|
||
o Do not make aerial or ground applications during temperature inversions. Inversions are characterized by stable
|
||
air and increasing temperatures with height above the ground. Mist or fog may indicate the presence of an
|
||
inversion in humid areas. The applicat or may detect the presence of an inversion by producing smoke and
|
||
observing a smoke layer near the ground surface.
|
||
o DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized
|
||
hand equipment.
|
||
|
||
5
|
||
|
||
|
||
APPLICATION INSTRUCTIONS
|
||
• USF0115 may be applied by either ground, aerial and/or chemigation application equipment. Equipment must be properly
|
||
calibrated before use.
|
||
• Complete coverage and uniform application are essential for the most effective results, especially when lower spray
|
||
volumes are applied. If necessary, increase the spray volume per acre for complete crop coverage.
|
||
• Thoroughly mix contents before use and application. Recirculate or mix the product for at least 5 minutes prior to each
|
||
use. For large containers, 15 gallons containers or more, mix the product with the built -in mixer for 5 -10 minutes before
|
||
each use.
|
||
|
||
Aerial Application
|
||
Apply in a minimum of 2 gallons of spray solution per acre unless stated differently in the RESTRICTIONS or the CROP USE
|
||
DIRECTIONS sections. Avoid application under conditions when uniform coverage cannot be obtained or when excessive spray drift
|
||
may occur. Aerial application is prohibited in New York State.
|
||
Check equipment calibration frequently.
|
||
|
||
Ground Application
|
||
Apply in a minimum of 10 gallons of spray solution per acre. Complete coverage and uniform application are essential for the m ost
|
||
effective results, especially when lower spray volumes are applied. If necessary, increase the spray volume per acre for complete crop
|
||
coverage.
|
||
|
||
CHEMIGATION
|
||
Apply USF0115 through irrigation equipment only to crops for which chemigation is specified on this label.
|
||
USF0115 alone or in combination with other pesticides, which are registered for application through irrigation systems, may be applied
|
||
through irrigation systems. Apply this product only through center pivot, solid set, hand move, or moving wheel irrigation systems. Do
|
||
not apply this product through any other type of irrigation system. Illegal pesticide residues in the crop can result from nonuniform
|
||
distribution of treated water. If you have questions about calibration, you should contact State Extension Service specialists, equipment
|
||
manufacturers, or other experts. Do not connect an irrigation system (including greenhouse systems) used for pesticide application to
|
||
a public water system, unless the pesticide label -prescribed safety devices for public water systems are in place. A person
|
||
knowledgeable of the chemigation system and responsible for its operation, or un der the supervision of the responsible person, shall
|
||
shut the system down and make necessary adjustments should the need arise.
|
||
|
||
Public water system
|
||
Public water system' means a system for the provision to the public of piped water for human consumption if such system has at least
|
||
15 service connections or regularly serves an average of at least 25 individuals daily at least 60 days out of the year. Chemigation
|
||
systems connected to public water systems must contain a functional, reduced-pressure zone (RPZ), back flow preventer, or the
|
||
functional equivalent in the water supply line upstream from the point of pesticide introduction. As an alternative to the RPZ, the water
|
||
from the public water system should be discharged into a reservoir tank prior to pesticide introduction. There shall be a complete
|
||
physical break (air gap) between the flow outlet end of the fill pipe and the top or overflow rim of the reservoir tank of at least twice the
|
||
inside diameter of the fill pipe. The pesticide injection pipeline must contain a functional, automatic, quick-closing check valve to prevent
|
||
the flow of fluid back toward the injection pump. Pesticide injection pipeline must contain a functional, normally closed, solenoid -
|
||
operated valve located on the intake side of the injection pump and connected to the system interlock to prevent fluid from being
|
||
withdrawn from the supply tank when the irrigation system is either automatically or manually shut down. The systems must contain
|
||
functional interlocking controls, to automatically shut off the pesticide injection pump when the water pump motor stops, or in cases
|
||
where there is no water pump, when the water pressure decreases to the point where pesticide distribution is adversely affected.
|
||
Systems must use a metering pump, such as a positive displacement injection pump (e.g., diaphragm pump) effectively designed and
|
||
constructed of materials that are compatible with pesticides and capable of being fitted with a system interlock.
|
||
|
||
Operating Instructions
|
||
1. The system must contain a functional check -valve, vacuum relief valve, and low -pressure drain appropriately located on the
|
||
irrigation pipeline to prevent water-source contamination from backflow.
|
||
2. The pesticide injection pipeline must contain a functional, automatic, quick -closing check-valve to prevent the flow of fluid back
|
||
toward the injection pump.
|
||
3. The pesticide injection pipeline must also contain a functional, normally closed, solenoid -operated valve located on the intake
|
||
side of the injection pump and connected to the system interlock to prevent fluid from being withdrawn from the supply tank w hen
|
||
the irrigation system is either automatically or manually shut down.
|
||
4. The system must contain functional interlocking controls to automatically shut off the pesticide injection pump when the wate r
|
||
pump motor stops.
|
||
5. The irrigation line or water pump must include a functional pressure switch, which will stop the water pump motor when the water
|
||
pressure decreases to the point where pesticide distribution is adversely affected.
|
||
6. Systems must use a metering pump, such as a positive displacement injection pump (e.g., diaphragm pump), effectively
|
||
designed, and constructed of materials that are compatible with pesticides and capable of being fitted with a system interlock.
|
||
|
||
6
|
||
|
||
|
||
7. Do not apply when wind speed favors drift beyond the area intended for treatment.
|
||
|
||
Center Pivot Irrigation Equipment
|
||
Notes: (1) Use only with drive systems, which provide uniform water distribution. (2) Do not use end guns when chemigating USF0115
|
||
through center pivot systems because of non-uniform application.
|
||
Determine the size of the area to be treated. Determine the time required to apply 1/8 -1/2 inch of water over the area to be treated
|
||
when the system and injection equipment are operated at normal pressures as recommended by the equipment manufacturer. When
|
||
applying USF0115 through irrigation equipment use the lowest obtainable water volume while maintaining uniform distribution. Run
|
||
the system at 80-95% of the manufacturer’s rated capacity. Using water, determine the injection pump output when operated at normal
|
||
line pressure. Determine the amount of USF0115 required to treat the area covered by the irrigation system. Add the required amount
|
||
of USF0115 and sufficient water to meet the injection time requirements to the solution tank. Make sure the system is fully charged
|
||
with water before starting injection of the USF0115 solution. Time the injection to last at least as long as it takes to bring the system
|
||
to full pressure. Maintain constant solution tank agitation during the injection period. Continue to operate the system until the USF0115
|
||
solution has cleared the sprinkler head.
|
||
|
||
Solid Set, Hand Move, and Moving Wheel Irrigation Equipment
|
||
When applying USF0115 through irrigation equipment use the lowest obtainable water volume while maintaining uniform distribution.
|
||
Determine the amount of USF0115 required to treat the area covered by the irrigation system. Add the required amount of USF0115
|
||
into the same quantity of water used to calibrate the injection period. Operate the system at the same pressure and time inte rval
|
||
established during the calibration. Stop injection equipment after treatment is completed. Continue to operate the system unt il the
|
||
USF0115 solution has cleared the last sprinkler head.
|
||
Adjuvants: USF0115 is recommended to be used with a registered non -ionic surfactant at the lowest specified labeled rate for
|
||
most uses. Refer to the USE DIRECTIONS FOR SPECIFIC CROPS for adjuvant recommendations on corn.
|
||
|
||
SPRAY DRIFT ADVISORIES
|
||
THE APPLICATOR IS RESPONSIBLE FOR AVOIDING OFF-SITE SPRAY DRIFT. BE AWARE OF NEARBY NON-
|
||
TARGET SITES AND ENVIRONMENTAL CONDITIONS.
|
||
|
||
Importance Of Droplet Size
|
||
An effective way to reduce spray drift is to apply large droplets. Use the largest droplets that provide target pest control. While applying
|
||
larger droplets will reduce spray drift, the potential for drift will be greater if applications are made improperly or under unfavorable
|
||
environmental conditions.
|
||
|
||
Controlling Droplet Size – Ground Boom
|
||
• Volume - Increasing the spray volume so that larger droplets are produced will reduce spray drift. Use the highest practical
|
||
spray volume for the application. If a greater spray volume is needed, consider using a nozzle with a higher flow rate.
|
||
• Pressure - Use the lowest spray pressure recommended for the nozzle to produce the target spray volume and droplet size.
|
||
• Spray Nozzle - Use a spray nozzle that is designed for the intended application. Consider using nozzles designed to reduce
|
||
drift.
|
||
|
||
Controlling Droplet Size – Aircraft
|
||
• Adjust Nozzles - Follow nozzle manufacturer’s recommendations for setting up nozzles. Generally, to reduce fine droplets,
|
||
nozzles should be oriented parallel with the airflow in flight.
|
||
|
||
Boom Height – Ground Boom
|
||
For ground equipment, the boom should remain level with the crop and have minimal bounce.
|
||
|
||
Release Height – Aircraft
|
||
Higher release heights increase the potential for spray drift.
|
||
|
||
Shielded Sprayers
|
||
Shielding the boom or individual nozzles can reduce spray drift. Consider using shielded sprayers. Verify that the shields are not
|
||
interfering with the uniform deposition of the spray on the target area.
|
||
|
||
Temperature And Humidity
|
||
When making applications in hot and dry conditions, use larger droplets to reduce effects of evaporation.
|
||
|
||
Temperature Inversions
|
||
Drift potential is high during a temperature inversion. Temperature inversions are characterized by increasing temperature with altitude
|
||
and are common on nights with limited cloud cover and light to no wind. The presence of an inversion can be indicated by ground fog or
|
||
by the movement of smoke from a ground source or an aircraft smoke generator. Smoke that layers and moves laterally in a
|
||
concentrated cloud (under low wind conditions) indicates an inversion, while smoke that moves upward and rapidly dissipates indicates
|
||
good vertical air mixing. Avoid applications during temperature inversions.
|
||
|
||
7
|
||
|
||
|
||
|
||
Wind
|
||
Drift potential generally increases with wind speed. AVOID APPLICATIONS DURING GUSTY WIND CONDITIONS. Applicators need
|
||
to be familiar with local wind patterns and terrain that could affect spray drift.
|
||
|
||
COMPATIBILITY TESTING AND TANK MIX PARTNERS
|
||
|
||
Mixing Procedures
|
||
Prepare no more spray mixture than is necessary for the immediate operation. Thoroughly clean spray equipment before using th is
|
||
product. Maintain maximum agitation throughout the spray operation. Do not let the spray mixture stand overnight in the spray tank.
|
||
Flush the spray equipment thoroughly following each use and apply the rinsate to the previously treated area or dispose of the rinsate
|
||
according to local regulations. Do not tank mix with products containing a prohibition against tank mixing. Follow th e most restrictive
|
||
labeling requirements of any tank mix product.
|
||
USF0115 alone: Add ½ of the required amount of water to the mix tank. With the agitator running, add the USF0115 to the tank.
|
||
Continue agitation while adding the remainder of the water. Begin application of the solution after the product has completel y and
|
||
uniformly dispersed into the mix water. Maintain agitation until all of the mixture has been applied.
|
||
USF0115 + Tank-Mix Partners: Add ½ of the required amount of water to the mix tank. Start the agitator running before adding any
|
||
of the tank-mix partners. In general, tank-mix partners should be added in this order: products packaged in water-soluble packaging*,
|
||
wettable powders, wettable granules (dry flowables), liquid flowables, liquids, and emulsifiable concentrates. Always allow each tank-
|
||
mix partner to become fully and uniformly dispersed before adding the next product. Provide sufficient agitation while adding the
|
||
remainder of the water. Maintain agitation until all of the mixture has been applied.
|
||
* Note: When using USF0115 in tank mixtures, all products in water-soluble packaging should be added to the tank before any other
|
||
tank-mix partner, including USF0115. Allow the water -soluble packaging to completely disperse before adding any other tank -mix
|
||
partner to the tank.
|
||
If using USF0115 in a tank mixture, observe all directions for use, crop/sites, use rates, dilution ratios, precautions, and limitations;
|
||
which appear on the tank-mix product label. Label dosage rate must not be exceeded, and the most restrictive label precautions and
|
||
limitations must be followed. This product must not be mixed with any product that prohibits such mixing. Tank mixtures or ot her
|
||
applications of products referenced on this label are permitted only in those states in which the referenced products are registered.
|
||
USF0115 is compatible with most insecticide, fungicide, herbicide, and foliar nutrient products. However, the physical compatibility of
|
||
USF0115 with tank-mix partners should be tested before use. To determine the physical compatibility of USF0115 with other products,
|
||
use a jar test, as described below.
|
||
Using a quart jar, add the proportionate amounts of the products to 1 qt. of water. Add wettable powders and water-dispersible granular
|
||
products first, then liquids and emulsifiable concentrates last. After thoroughly mixing, let stand for at least 5 minutes. If the combination
|
||
remains mixed or can be remixed readily, it is physically compatible. Once compatibility has been proven, use the same procedure for
|
||
adding required ingredients to the spray tank. For further information, contact your local Bayer Crop Science representative.
|
||
The crop safety of all potential tank mixes including additives and other pesticides on all crops has not been tested. Before applying
|
||
any tank mixture not specified on this label, the safety to the target crop should be confirmed. To test for crop safety, apply USF0115
|
||
to the target crop in a small area and in accordance with label instructions for the target crop.
|
||
|
||
FUNGICIDE RESISTANCE MANAGEMENT (FRAC) RECOMMENDATIONS
|
||
For resistance management, please note that USF0115 contains both Group 3 (prothioconazole and tebuconazole) and Group 7
|
||
(fluopyram) fungicides. Any fungal population may contain individuals naturally resistant to USF0115 and other Group 3 and Group 7
|
||
fungicides. A gradual or total loss of pest control may occur over time if these (fungicides) are used repeatedly in the same fields.
|
||
Appropriate resistance-management strategies should be followed.
|
||
|
||
To delay fungicide resistance, take one or more of the following steps:
|
||
• Rotate the use of USF0115 fungicide within a growing season with other fungicide groups that control the same pathogens.
|
||
• Use tank mixtures with fungicide from a different group that are equally effective on the target pest when such use is permitted.
|
||
• Use at least the minimum application rate as labeled by the manufacturer.
|
||
• Adopt an integrated disease management program for fungicide use that includes scouting, uses historical information related to
|
||
pesticide use, and crop rotation, and which considers host plant resistance, impact of environmental conditions on disease
|
||
development, disease thresholds, as well as cultural, biological and other chemical control practices.
|
||
• Where possible, make use of predictive disease models to effectively time fungicide applications. Note that using predictive models
|
||
alone is not sufficient to manage resistance.
|
||
• Monitor treated fungal/bacterial populations for resistance development.
|
||
• Contact your local extension specialist or certified crop advisor for any additional pesticide resistance-management and/or IPM
|
||
recommendations for specific crops and pathogens.
|
||
• For further information or to report suspected resistance contact Bayer CropScience at 1 -866-99BAYER (1-866-992-2937). You
|
||
can also contact your pesticide distributor or university extension specialist to report resistance.
|
||
|
||
8
|
||
|
||
|
||
ROTATIONAL RESTRICTIONS
|
||
Treated areas may be replanted with barley, corn (field corn, field corn grown for seed, and popcorn), dry beans (except cowpea),
|
||
peanuts, soybeans, triticale, and wheat as soon as practical after last application. Do not rotate to sweet corn within 30 days of the
|
||
last application. The following crops can be replanted 120 days after the last application of USF0115. Do not rotate to crops other
|
||
than those listed below:
|
||
Additional cereals not listed on this label, Alfalfa, Artichoke, (Globe); Brassica (cole) leafy vegetables (group 5); Bulb vegetables
|
||
(group 3-07); Carrot; Citrus (group 10-10); Cotton (subgroup 20C); Cucurbits (group 9); Dill seed; Fruiting Vegetables (group 8-10);
|
||
Ginseng; Grapes and small vines (except fuzzy kiwifruit) (subgroup 13-07F); Herb (subgroup 19A); Hops; Leafy vegetables (except
|
||
watercress) (group 4); Legume Vegetables (except cowpea and dried peas); Pome fruit (group 11-10); Potato and other root,
|
||
tuberous and corm vegetables (except sugarbeet) (subgroups 1B and 1C); Rapeseed (subgroup 20A); Small Berries (caneberries
|
||
and bushberries) (subgroups 13-07A and 13-07B); Stone Fruits (group 12-12); Strawberry and other low-growing berries, except
|
||
cranberry (subgroup 13-07G); Sugarbeet; Sugarcane (Region 3); Sunflower (subgroup 20B); Tobacco; Tree Nuts (group 14-12).
|
||
|
||
9
|
||
|
||
|
||
CROP USE DIRECTIONS
|
||
|
||
BARLEY
|
||
Disease Controlled Product Rate (fl oz/A) Product Instructions
|
||
Leaf and Stem Diseases
|
||
Net Blotch
|
||
(Pyrenophora teres)
|
||
|
||
Powdery Mildew
|
||
(Blumeria graminis f. sp. hordei)
|
||
|
||
Scald
|
||
(Rhynchosporium secalis)
|
||
|
||
Spot Blotch
|
||
(Bipolaris sorokiniana)
|
||
|
||
Rusts
|
||
(Puccinia spp.)
|
||
10.3 – 13.6
|
||
|
||
(0.134 lbs prothioconazole/A +
|
||
0.067 lbs tebuconazole/A + 0.067 lbs
|
||
fluopyram/A to 0.177 lbs
|
||
prothioconazole/A + 0.089 lbs
|
||
tebuconazole/A + 0.089 lbs
|
||
fluopyram/A)
|
||
Straw cut after harvest may be fed or used for
|
||
bedding.
|
||
|
||
When applied through chemigation, large
|
||
carrier volumes may result in reduced
|
||
activity against Fusarium head blight.
|
||
|
||
Disease Suppressed Product Rate (fl oz/A) Product Instructions
|
||
Fusarium Head Blight
|
||
(Fusarium spp.)
|
||
10.3 – 13.6
|
||
|
||
(0.134 lbs prothioconazole/A +
|
||
0.067 lbs tebuconazole/A + 0.067 lbs
|
||
fluopyram/A to 0.177 lbs
|
||
prothioconazole/A + 0.089 lbs
|
||
tebuconazole/A + 0.089 lbs
|
||
fluopyram/A)
|
||
The optimal time to apply USF0115 is as a
|
||
preventative foliar spray when barley heads on
|
||
the main stem are fully emerged (~ Feekes
|
||
Growth Stage 10.5). Spray equipment must be
|
||
set to provide good coverage of barley heads.
|
||
For thorough coverage of the barley head using
|
||
ground application equipment, use forward,
|
||
forward and backward mounted nozzles, or
|
||
nozzles that have a two-directional spray.
|
||
Nozzles should be operated within the spray
|
||
pressure directions suggested by the
|
||
manufacturer.
|
||
|
||
For aerial applications made prior to heading
|
||
(prior to Feekes Growth Stage 10.5), apply a
|
||
minimum of 2 gpa spray solution. For aerial
|
||
applications made at the heading growth stage
|
||
or later, apply in a minimum of 3 gpa spray
|
||
solution. Chemigation use is allowed only for
|
||
applications made prior to heading. Higher
|
||
carrier volumes increase the likelihood of more
|
||
complete coverage of the grain heads.
|
||
Restrictions:
|
||
• Pre-Harvest Interval (PHI): 32 days
|
||
• Do not make more than one application of USF0115 per year.
|
||
• Grazing livestock or feeding of green forage is only permitted 14 or more days after the last application of USF0115.
|
||
• Minimum ground application volume: 10 gallons/Acre
|
||
• For aerial applications made prior to heading (prior to Feekes Growth Stage 10.5), apply a minimum of 2 gpa spray
|
||
solution. For aerial applications made at the heading growth stage or later, apply in a minimum of 3 gpa spray solution.
|
||
Chemigation use is allowed only for applications made prior to heading.
|
||
• Maximum USF0115 allowed per year: 13.6 fluid ounces/Acre (0.177 lbs prothioconazole, 0.089 lbs tebuconazole, 0.089 lbs
|
||
fluopyram per acre).
|
||
• Regardless of formulation or method of application, do not apply more than 0.293 lbs prothioconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.113 lbs tebuconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.223 lbs fluopyram per acre per year.
|
||
• Do not make more than 2 sequential applications of a Group 7 containing product before rotating to a fungicide from a
|
||
different group.
|
||
• DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized hand
|
||
equipment.
|
||
|
||
10
|
||
|
||
|
||
CORN1
|
||
Field Corn, Field Corn Grown For Seed and Popcorn
|
||
Disease Controlled Product Rate (fl oz/A) Product Instructions
|
||
Anthracnose
|
||
(Colletotrichum graminicola)
|
||
|
||
Eye spot
|
||
(Aureobasidium zeae)
|
||
|
||
Gray leaf spot
|
||
(Cercospora zeae-maydis)
|
||
|
||
Northern corn leaf blight
|
||
(Setosphaeria turcica)*
|
||
|
||
Northern corn leaf spot
|
||
(Cochliobolus carbonum)*
|
||
|
||
Rust
|
||
(Puccinia spp.)
|
||
|
||
Southern corn leaf blight
|
||
(Cochliobolus heterostrophus)*
|
||
|
||
Tar spot
|
||
(Phyllachora maydis)
|
||
|
||
*The above diseases are also known as
|
||
Helminthosporium leaf blights
|
||
|
||
|
||
|
||
10.3
|
||
|
||
(0.134 lbs prothioconazole/A + 0.067 lbs
|
||
tebuconazole/A + 0.067 lbs fluopyram/A)
|
||
Under some conditions, the lowest
|
||
specified labeled rate of a spray
|
||
adjuvant may be tank-mixed with
|
||
USF0115 to improve performance.
|
||
|
||
Apply USF0115 when disease first
|
||
appears.
|
||
Restrictions:
|
||
• Pre-Harvest Interval (PHI) for forage: 21 day(s), Do not allow livestock to graze corn forage within 21 days of application.
|
||
• Pre-Harvest Interval (PHI) for grain or fodder: 36 day(s), Do not allow livestock to graze corn fodder within 36 days of
|
||
application.
|
||
• Minimum interval between applications: 14 days
|
||
• Minimum application volumes: 10 gallons/Acre (Ground); 2 gallons/Acre (Aerial)
|
||
• Maximum USF0115 allowed per year: 41.2 fluid ounces/Acre (0.538 lbs prothioconazole, 0.270 lbs tebuconazole, 0.270 lbs
|
||
fluopyram per acre).
|
||
• Do not use adjuvants if USF0115 is applied between corn growth stages V8 (8 leaf collar) and VT (lowest branch of the
|
||
tassel is visible but silks have not emerged).
|
||
• Do not make more than 2 sequential applications of a Group 7 containing product before rotating to a fungicide from a
|
||
different group.
|
||
• Regardless of formulation or method of application, do not apply more than 0.713 lbs prothioconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.675 lbs tebuconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.446 lbs fluopyram per acre per year.
|
||
• DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized hand
|
||
equipment.
|
||
|
||
1 Not for use on corn in New York.
|
||
|
||
11
|
||
|
||
|
||
PEANUT
|
||
Foliar Disease Controlled Product Rate (fl oz/A) Product Instructions
|
||
Early Leaf spot
|
||
(Cercospora arachidicola)
|
||
|
||
Late Leaf Spot
|
||
(Cercosporidium personatum)
|
||
|
||
Leaf Rust
|
||
(Puccinia arachidis)
|
||
|
||
Web Blotch
|
||
(Phoma arachidicola)
|
||
|
||
Leaf Scorch and Pepper Spot
|
||
(Leptosphaerulina crassiasca)
|
||
10.3 - 13.6
|
||
|
||
(0.134 lbs
|
||
prothioconazole/A +
|
||
0.067 lbs tebuconazole/A +
|
||
0.067 lbs fluopyram/A to
|
||
0.178 lbs prothioconazole/A
|
||
+ 0.089 lbs tebuconazole/A +
|
||
0.089 lbs fluopyram/A)
|
||
USF0115 must be carried by rainfall or
|
||
irrigation into the root and pod zone for
|
||
control of root and pod rots.
|
||
Soil-Borne Disease Controlled Product Rate (fl oz/A)
|
||
Sclerotium Rot, White Mold, Southern
|
||
Blight, Southern Stem Rot
|
||
(Sclerotium rolfsii)
|
||
|
||
Rhizoctonia Limb Rot, Peg Rot, Pod Rot
|
||
(Rhizoctonia solani)
|
||
|
||
|
||
10.3 - 13.6
|
||
|
||
(0.134 lbs
|
||
prothioconazole/A +
|
||
0.067 lbs tebuconazole/A +
|
||
0.067 lbs fluopyram/A to
|
||
0.178 lbs prothioconazole/A
|
||
+ 0.089 lbs tebuconazole/A +
|
||
0.089 lbs fluopyram/A)
|
||
Soil-Borne Disease Suppressed Product Rate (fl oz/A)
|
||
|
||
Cylindrocladium Black Rot
|
||
(Cylindrocladium crotalariae)
|
||
|
||
10.3 - 13.6
|
||
|
||
(0.134 lbs
|
||
prothioconazole/A +
|
||
0.067 lbs tebuconazole/A +
|
||
0.067 lbs fluopyram/A to
|
||
0.178 lbs prothioconazole/A
|
||
+ 0.089 lbs tebuconazole/A +
|
||
0.089 lbs fluopyram/A)
|
||
Restrictions:
|
||
• Pre-Harvest Interval (PHI): 14 day(s)
|
||
• Do not feed hay or thrashings or allow livestock to graze in treated areas.
|
||
• Minimum interval between applications: 14 days
|
||
• Minimum application volumes: 10 gallons/Acre (Ground); 2 gallons/Acre (Aerial)
|
||
• Maximum USF0115 allowed per year: 54.6 fluid ounces/Acre (0.712 lbs prothioconazole, 0.358 lbs tebuconazole, 0.358 lbs
|
||
fluopyram per acre).
|
||
• Do not make more than 2 sequential applications of a Group 7 containing product before rotating to a fungicide from a different
|
||
group.
|
||
• Regardless of formulation or method of application, do not apply more than 0.713 lbs prothioconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.810 lbs tebuconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.446 lbs fluopyram per acre per year.
|
||
• DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized hand equipment.
|
||
|
||
12
|
||
|
||
|
||
WHEAT
|
||
(Spring, Durum, And Winter)
|
||
Disease Controlled Product Rate (fl oz/A) Product Instructions
|
||
Fusarium Head Blight
|
||
(Fusarium spp.)
|
||
|
||
Leaf and Stem Diseases
|
||
Powdery Mildew
|
||
(Blumeria graminis f. sp. tritici)
|
||
|
||
Rusts
|
||
(Puccinia spp.)
|
||
|
||
Septoria Leaf Blotch
|
||
(Septoria tritici)
|
||
|
||
Stagonospora Blotch
|
||
(Stagonospora nodorum)
|
||
|
||
Tan Spot
|
||
(Pyrenophora tritici-repentis)
|
||
|
||
10.3 – 13.6
|
||
|
||
(0.134 lbs prothioconazole/A +0.067 lbs
|
||
tebuconazole/A + 0.067 lbs fluopyram/A to
|
||
0.177 lbs prothioconazole/A + 0.089 lbs
|
||
tebuconazole/A + 0.089 lbs fluopyram/A)
|
||
Straw may be fed or used for bedding.
|
||
|
||
Fusarium Head Blight and Ergot
|
||
Target application after 75% of the wheat
|
||
heads on the main stem are fully emerged until
|
||
flowering has ended. Optimal application
|
||
timing for deoxynivalenol (DON) reduction is
|
||
when first flowers emerge on the main heads.
|
||
Spray equipment must be set to provide good
|
||
coverage to wheat heads. For thorough
|
||
coverage of the wheat head using ground
|
||
application equipment, use forward, forward
|
||
and backward mounted nozzles, or nozzles
|
||
that have a two-directional spray. Operate
|
||
nozzles within the spray pressure directions
|
||
suggested by the manufacturer. When applied
|
||
through chemigation, large carrier volumes
|
||
may result in reduced activity against Fusarium
|
||
head blight and ergot.
|
||
|
||
For aerial application made prior to early flower
|
||
(prior to Feekes Growth Stage 10.51, apply a
|
||
minimum of 2 gpa spray solution. For aerial
|
||
applications made at the early flower growth
|
||
stage or later, apply in a minimum of 3 gpa
|
||
spray solution. Chemigation use is allowed
|
||
only for applications made prior to early flower.
|
||
Higher carrier volumes increase the likelihood
|
||
of more complete coverage of the grain heads.
|
||
|
||
Leaf and Stem Diseases
|
||
Apply USF0115 as a preventive foliar spray
|
||
when the earliest disease symptoms appear
|
||
on the leaves and stems. Wheat fields should
|
||
be observed closely for early disease
|
||
symptoms, particularly when susceptible
|
||
varieties are planted and/or under prolonged
|
||
conditions favorable for disease development.
|
||
Disease Suppressed Product Rate (fl oz/A)
|
||
|
||
Ergot
|
||
(Claviceps purpurea)
|
||
|
||
|
||
10.3 – 13.6
|
||
|
||
(0.134 lbs prothioconazole/A +0.067 lbs
|
||
tebuconazole/A + 0.067 lbs fluopyram/A to
|
||
0.177 lbs prothioconazole/A + 0.089 lbs
|
||
tebuconazole/A + 0.089 lbs fluopyram/A)
|
||
Restrictions:
|
||
• Pre-Harvest Interval (PHI): 30 day(s)
|
||
• Minimum interval between applications: 14 days
|
||
• Do not allow livestock to graze or feed green forage to livestock prior to 14 days after treatment with USF0115.
|
||
• Minimum ground application volume: 10 gallons/Acre
|
||
• For aerial application made prior to early flower (prior to Feekes Growth Stage 10.51, apply a minimum of 2 gpa spray solution.
|
||
For aerial applications made at the early flower growth stage or later, apply in a minimum of 5 gpa spray solution. Chemigation
|
||
use is allowed only for applications made prior to early flower.
|
||
• Maximum USF0115 allowed per year: 13.6 fluid ounces/Acre (0.177 lbs prothioconazole, 0.089 lbs tebuconazole, 0.089 lbs
|
||
fluopyram per acre).
|
||
• Do not make more than 2 sequential applications of a Group 7 containing product before rotating to a fungicide from a different
|
||
group.
|
||
• Regardless of formulation or method of application, do not apply more than 0.293 lbs prothioconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.113 lbs tebuconazole per acre per year.
|
||
• Regardless of formulation or method of application, do not apply more than 0.223 lbs fluopyram per acre per year.
|
||
• DO NOT use with handheld application equipment, including backpack or mechanically/manually pressurized hand equipment.
|
||
|
||
13
|
||
|
||
|
||
STORAGE AND DISPOSAL
|
||
Do not contaminate water, food, or feed by storage or disposal.
|
||
|
||
Pesticide storage
|
||
Store in a cool, dry place and in such a manner as to prevent cross contamination with other pesticides, fertilizers, food, and feed. Store
|
||
in original container and out of the reach of children, preferably in a locked storage area.
|
||
Handle and open container in a manner as to prevent spillage. If container is leaking, invert to prevent leakage. If the container is leaking
|
||
or material is spilled for any reason or cause, carefully dam up spilled material to prevent runoff. Refer to Precautionary Statements on
|
||
label for hazards associated with the handling of this material. Do not walk through spilled material. Absorb spilled material with
|
||
absorbing type compounds and dispose of as directed for pesticides below. In spill or leak incidents, keep unauthorized people away.
|
||
|
||
Pesticide disposal
|
||
Wastes resulting from the use of this product may be disposed of on site or at an approved waste disposal facility.
|
||
|
||
Container handling
|
||
[Non-Refillable Containers]
|
||
|
||
Rigid, Non-refillable containers (equal to or less than 5 gallons)
|
||
Non-refillable container. Do not reuse or refill this container. Triple rinse or pressure rinse container (or equivalent) promptly after
|
||
emptying. Triple rinse as follows: Empty the remaining contents into application equipment or a mix tank and drain for 10 seconds after
|
||
the flow begins to drip. Fill the container 1/4 full with water and recap. Shake for 10 seconds. Pour rinsate into application equipment or
|
||
a mix tank or store rinsate for later use or disposal. Drain for 10 seconds after the flow begins to drip. Repeat this procedure two more
|
||
times.
|
||
|
||
Pressure rinse as follows: Empty the remaining contents into application equipment or a mix tank and continue to drain for 10 seconds
|
||
after the flow begins to drip. Hold container upside down over application equipment or mix tank or collect rinsate for later use or
|
||
disposal. Insert pressure rinsing nozzle in the side of the container, and rinse at about 40 PSI for at least 30 seconds. Drain for 10
|
||
seconds after the flow begins to drip.
|
||
|
||
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill or by incineration.
|
||
|
||
Rigid Non-refillable Containers that are too large to shake (i.e., with capacities greater than 5 gallons or 50 lbs)
|
||
Non-refillable container. Do not reuse or refill this container. Refer to Bottom Discharge IBC or Top Discharge IBC, Drums, Kegs
|
||
information as follows.
|
||
|
||
Bottom Discharge IBC (e.g. – Schuetz Caged IBC or Snyder Square Stackable)
|
||
Pressure rinsing the container before final disposal is the responsibility of the person disposing of the container. To pressure rinse the
|
||
container before final disposal, empty the remaining contents from the IBC into application equipment or mix tank. Raise the bottom of
|
||
the IBC by 1.5 inches on the side which is opposite of the bottom discharge valve to promote more complete product removal.
|
||
Completely remove the top lid of the IBC. Use water pressurized to at least 40 PSI to rinse all interior portions. Continuously pump or
|
||
drain rinsate into application equipment or rinsate collection system while pressure rinsing. Continue pressure rinsing for 2 minutes or
|
||
until rinsate becomes clear. Replace the lid and close bottom valve.
|
||
Top Discharge IBC, Drums, Kegs (e.g.– Snyder 120 Next Gen, Bonar B120, Drums, Kegs)
|
||
Triple rinsing the container before final disposal is the responsibility of the person disposing of the container. To triple rinse the container
|
||
before final disposal, empty the remaining contents from this container into application equipment or mix tank. Fill the container at least
|
||
10 percent full with water. Agitate vigorously or recirculate water with the pump for 2 minutes. Rinse all interior surfaces. Pour or pump
|
||
rinsate into application equipment or rinsate collection system. Repeat this procedure two more times.
|
||
|
||
Top Discharge IBC, Drums, Kegs (e.g.– Snyder 120 Next Gen, Bonar B120, Drums, and Kegs)
|
||
Triple rinsing the container before final disposal is the responsibility of the person disposing of the container. To triple rinse the container
|
||
before final disposal, empty the remaining contents from this container into application equipment or mix tank. Fill the container at least
|
||
10 percent full with water. Agitate vigorously or recirculate water with the pump for 2 minutes. Rinse all interior surfaces. Pour or pump
|
||
rinsate into application equipment or rinsate collection system. Repeat this procedure two more times.
|
||
|
||
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill or by incineration.
|
||
|
||
Non-Rigid, Non-refillable Containers
|
||
Nonrefillable container. Do not reuse or refill this container. Completely empty container into application equipment. Then offer for
|
||
recycling if available or dispose of in a sanitary landfill or by other procedures approved by state and local authorities.
|
||
|
||
[Refillable Containers]
|
||
|
||
Refillable container. Refer to Bottom Discharge IBC or Top Discharge IBC, Drums, Kegs information as follows. Refill this container with
|
||
pesticide only. Do not reuse this container for any other purpose. Contact your Ag retailer or Bayer CropScience for container return,
|
||
disposal and recycling information.
|
||
|
||
14
|
||
|
||
|
||
Bottom Discharge IBC (e.g. – Schuetz Caged IBC or Snyder Square Stackable)
|
||
Pressure rinsing the container before final disposal is the responsibility of the person disposing of the container. Cleaning before refilling
|
||
is the responsibility of the refiller. To pressure rinse the container before final disposal, empty the remaining contents from the IBC into
|
||
application equipment or mix tank. Raise the bottom of the IBC by 1.5 inches on the side which is opposite of the bottom discharge valve
|
||
to promote more complete product removal. Completely remove the top lid of the IBC. Use water pressurized to at least 40 PSI to rinse
|
||
all interior portions. Continuously pump or drain rinsate into application equipment or rinsate collection system while pressure rinsing.
|
||
Continue pressure rinsing for 2 minutes or until rinsate becomes clear. Replace the lid and close bottom valve.
|
||
|
||
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill or by incineration.
|
||
|
||
Top Discharge IBC, Drums, Kegs (e.g.– Snyder 120 Next Gen, Bonar B120, Drums, Kegs)
|
||
Triple rinsing the container before final disposal is the responsibility of the person disposing of the container. Cleaning before refilling is
|
||
the responsibility of the refiller. To triple rinse the containers before final disposal, empty the remaining contents from this container into
|
||
application equipment or mix tank. Fill the container at least 10 percent full with water. Agitate vigorously or recirculate water with the
|
||
pump for 2 minutes. Rinse all interior surfaces. Pour or pump rinsate into application equipment or rinsate collection system. Repeat this
|
||
procedure two more times.
|
||
|
||
Once container is rinsed, offer for recycling if available or puncture and dispose of in a sanitary landfill or by incineration.
|
||
|
||
End users are authorized to remove tamper-evident cables as required to remove the product from the container unless the container is
|
||
equipped with one-way valves and refilling or returning is planned. If this is the case, end-users are not authorized to remove tamper-
|
||
evident cables, remove one-way valves, or clean container.
|
||
|
||
USF0115 (PENDING) 11/22/2021, 06/22/2026, 06/23/2026, 07/23/2026, 07/29/2026
|